Mon Nov 7 13:15:07 2016, Alvaro, Ale, Jorge, Jose, Background
|
Background measurement overnight.
Start: 23:27 (07/11/2016)
|
Mon Nov 7 13:11:42 2016, Alvaro, Ale, Jose, Jorge, New directory and Config file
|
For second part of Takechi's run:
Directory: /data/1611Commissioning/161107Parasitic
|
Mon Nov 7 09:05:09 2016, Iris, Draft for Run sheet 
|
Attached is the draft for the paper run sheet (version 2). If something is missing, please let me know. |
Mon Nov 7 09:04:10 2016, Phong,Liu,Ale,Jose, New AIDA plastic calibration
|
To have a range of about 200 MeV
Ortec671 Gain from x20 to x5 (fine gain : x0.5)
|
Mon Nov 7 06:55:01 2016, NTB, SG, HPGe Fill line to D4 replaced
|
HPGe fill line to D4 replaced only small leak (overflow) once Ge is full.
Solenoid was also wrapped to no effect. AIDA DAQ still stops writing.
Boron sheet and extra polyethylene were placed back on top. |
Mon Nov 7 05:36:20 2016, Ale, new calibration for F11
|
new calibration for F11
Using a value of 70 MeV energy loss and the file 161107_0833_Overnight.root
|
Mon Nov 7 04:49:57 2016, Tain, Ale, AIDA plastic (veto) and Si de calibration
|
AIDA plastic (veto) and Si de calibration
For the calibration the Compton edge of the spectrum seen in the detectors was used.
|
Mon Nov 7 04:37:33 2016, Phong,Liu,..., Si de and AIDA plastic calibration
|
60Co source placed close to the detectors:
ROOT files:
|
Mon Nov 7 02:39:55 2016, Ale, Photo of the white board with the details on the cards and preamps at B1F
|
Photo of the white board with the details on the cards and preamps at B1F |
Sun Nov 6 23:35:42 2016, Tain et al., Overnight measurement: Ca isotopes  
|
First 50,49,48Ca beam and then 47,46,45Ca beam
C-6mm IN and OUT
|
Sun Nov 6 07:16:59 2016, Tain et al., 58Ni on F7 CH2 F11 empty/C6mm 
|
CH2 target at F7 in
Start with Empty at F11
Change to C-6mm at F11 later
|
Sun Nov 6 06:39:23 2016, Tain et al., 58Ni on F11 C-6mm
|
58Ni in F11 C-6mm (later empty)
F7 CH2 target out (F5 CH2 target in)
Thresholds in V_PL_* lowered from 20MeV to 1MeV
|
Sun Nov 6 06:27:49 2016, Tain et al., 58Ni on F11 C-6mm in
|
New calibration in V_PL_T and V_PL_R (Energyx1/2)
Start: 15:15
|
Sun Nov 6 03:12:55 2016, Alvaro,Jorge, Overnight measurement
|
Measurement during beam production
and measurement with F7 CH2 out,
F11 C-tar in/out, F7 CH2 in C-target out/in
|
Sat Nov 5 17:07:27 2016, Tain, Alvaro, Jorge, 62Ni in F7    
|
62Ni beam in F7 ON CH2 target
Strat with C target ladder in F11 in empty position.
|
Sat Nov 5 16:27:13 2016, Tain,Ale,Jorge,Alvaro, 62Ni beam in F11 empty target
|
Empty position of the target ladder at F11
(hole is smaller than beam size)
|
Sat Nov 5 15:07:11 2016, Tain, Ale, 62Ni beam on F11 C-6mm    
|
62Ni on 6 mm C target between MUSICs
The background before was 0.36 neutrons/s
|
Sat Nov 5 03:36:34 2016, Tain et al, Ancillary detectors  
|
Some info on ancillary detector signals
Plastic veto detectors (Top and Botomm):
|
Sat Nov 5 03:18:13 2016, SG BCR RCF NTB, Gamma peaks in the overnight run, related to neutron inelastic scattering 
|
We looked at the overnight background run (161105_0935_BackgroundOvernight.root), There are gamma-peaks that could be related to neutron inerastic
scattering. We identified 565, 596, 608 and 69 keV. They might be related to the effect of neutrons. If this is the correct assignment, this would mean
at least some of the neutrons are not thermal when they interact with the germanium. |
Sat Nov 5 01:26:46 2016, Jose,Iris,Alvaro, Alejandro, Krzysztof, Background measurement 7x
|
Measurement overnight
Start: around 1:00
|