  BRIKEN, Page 18 of 21  ELOG logo
Entry  Thu May 25 12:53:47 2017, AT, PC, JLT, KR, AA, Clover, 60Co 
60Co source 

Source ID: CD395
Entry  Mon Nov 5 18:05:48 2018, AT, JR, FM, PA, Low threshold, 252Cf, z=25cm, perpendicular 0 deg 
252Cf at z=25cm, i.e 25 cm from the center of the detector,  source axis perpendicular  
Low threshold.
Entry  Mon Nov 5 19:55:20 2018, AT, JR, FM, PA, Low threshold, 252Cf, z=0cm, perpendicular 90 deg 
252Cf at z=0cm, i.e 0 cm from the center of the detector,  source axis perpendicular at 90 deg 
Low threshold.
Entry  Mon Nov 5 21:24:20 2018, AT, JR, FM, PA, Low threshold, 252Cf, z=25cm, perpendicular 90 deg 
252Cf at z=25cm, i.e 25 cm from the center of the detector,  source axis perpendicular at 90 deg 
Low threshold.
Entry  Mon Nov 5 22:47:40 2018, AT, JR, FM, PA, Low threshold, 252Cf, z=0cm, perpendicular 0 deg Screenshot_from_2018-11-06_08-32-50.png
252Cf at z=0cm, i.e 0 cm from the center of the detector,  source axis perpendicular at 0 deg 
Low threshold.
Entry  Thu May 25 12:49:55 2017, AT, JLT,PC,AA, Clover, 133Ba, LN2 filling 
We started the measurement of the source when the N2 filling started. Just to  check if there are funny things
related to the filling.
Entry  Thu May 25 14:31:46 2017, AT, JLT, AA, AIM, Background measurement 7x
Background, No AIDA

Start:22:31
Entry  Thu May 25 13:56:00 2017, AT, JLT, AA, 252Cf 
252Cf source in Z=0cm position. 

Start:21:57
Entry  Sun Oct 28 07:41:03 2018, AT, JA, AA, Background 
Dacq was reinitialized
Background was measurement
Pulser: YES
Entry  Fri May 26 02:17:40 2017, AT, AIM, JLT,AA, PV, KM, 152Eu 
Calibration with 152Eu source.

START time:10:15
Entry  Sat Nov 26 16:54:17 2016, AT & AT, Clovers 
Calibration of clovers
Entry  Wed Oct 17 09:20:20 2018, AT & AT, 252Cf long measure 
18/10/17 START: 18:16
18/10/17 STOP: 22:00
Entry  Wed Oct 17 14:11:18 2018, AT & AT, 252Cf long measure, z=0cm, threshold 5% lower 

18/10/17 START: 22:04
18/10/17 STOP: 08:18
Entry  Thu Oct 18 00:31:55 2018, AT & AT, 252Cf long measure, z=0cm, threshold 5% lower 
18/10/18 START: 08:31
18/10/18 STOP: 10:50
Entry  Thu Oct 18 03:11:56 2018, AT & AT, bck meas 
18/10/18 START: 10:54
18/10/1X STOP: 14:02
Entry  Fri Oct 19 04:02:36 2018, AT & AT, 252Cf, z=0cm, no clovers (***** CHECK DATA) 

18/10/19 START: 12:05
18/10/19 STOP: 16:44
Entry  Fri Oct 19 10:27:22 2018, AT & AT, 252Cf, z=0cm, no clovers (***** CHECK DATA) 

18/10/19 START: 18:25
18/10/19 STOP: 19:19
Entry  Fri Oct 19 11:28:31 2018, AT & AT, 252Cf, z=0cm, no clovers, test online dead time 
During previous measurement a high dead time in the online was observed (50%). after restarting the crates and
the GASIFIC70, we resume the measurement. The conf file is 
Entry  Fri Oct 19 11:45:12 2018, AT & AT, 252Cf, z=0cm, no clovers 

18/10/19 START: 19:46
18/10/19 STOP: 23:33
Entry  Fri Oct 19 15:38:11 2018, AT & AT, 252Cf, z=0cm, no clovers, noise check individual tubes Screenshot_from_2018-10-20_18-45-17.png

18/10/19 START: 23:39
18/10/20 STOP: 18:30