Optimised motor motion during run R58
Moved 2 mm in (20.3 potentiometer)
29.47 potentiometer
36.5 potentiometer
(started moving pneumatic)
64.36 potentiometer
74.03 potentiomater (servo in by 10 mm)
Moved in, collected counts for 5 minutes, moved out, waited for re-injection.
20.3 - 400 counts on the Rutherford peak, bins 125-131 on lowEnergyExTotalDSSD0
20.47 - 646
36.5 - 827
64.36 - 3900
74.03 - 10040
Based on Rutherford rate ratio, estimated we are 40-50 mm away from interaction point, i.e. beam roughly 1-2 cm on outer half of ring which may be consistent with BPM measurement in YR08
Decided to use 74.03 mm for data collection.
Started data acquisition on R59 at 17:27
Beam 3E7 at injection, 600 second storage, 3 second between cycles
Target pressure 1.3E12 based on 8.21E18 x S1=1.6E-8 |