Mounted water manifold on CARME with help from GSI plumber. Connected all the hoses with Swagelok self-locking connectors. Tested for water leaks - it leaks from nearly every port. The issue appear to be the connections between the manifold and the plugs, as opposed to the plugs and the hoses which do not leak.
Will try to find a solution tomorrow.
FEEs connected from bottom-left, top-left and top-right detector.
Top right detector showed same behaviour described in previous ELOG entry. Removed all jumpers from PCBs. Beahaviour is gone.
Removed all jumpers from flexi-rigid PCBs for bottom-left detector. Behaviour is improved, but not gone - still 13 uA at 150V. Around 3.5 uA at 120V with no conditioning - that may be the working point.
Missing
- Power cables and ethernet cables for half the fees
- Fix leaks on water manifold
- Fix / change / re-arrange fee holder for bottom-right detector to avoid it fouling on CARME frame. |