AIDA GELINA BRIKEN nToF CRIB ISOLDE CIRCE nTOFCapture DESPEC DTAS EDI_PSA 179Ta CARME StellarModelling DCF K40
  CARME  ELOG logo
Message ID: 631     Entry time: Fri Jun 14 14:48:02 2024
Author: CB NP ML 
Subject: [How To] Change target pressure. EMERGENCY ONLY! 

ONLY FOLLOW THESE INSTRUCTIONS if E1 turbo is below 820 Hz, pressure in E1 is above 2.5E-1 mbar and experts (Nikos, Andreas) cannot be reached.

 

Go to the red cabinet under the stairs.

Open rightmost door. See first photo. Do not press the button on the handle or the door will lock!

Turn down pressure regulator indicated in second photo by approximately 1 degree. Read regulator to know which way to turn to decrease. No immediate change should be obvious on the pressure regulator.

Check E1 pressure for 5 minutes. If no effect, turn pressure down again until an effect appears.

Attachment 1: 20240614_142435.jpg  2.267 MB  Uploaded Fri Jun 14 15:54:13 2024  | Hide | Hide all