Wed Mar 2 06:00:49 2022, Spillmann, Uwe, waiting
|
07:00
Target density is hovering between 2.0e-8 and 2.3e-8 |
Tue Feb 22 19:28:35 2022, David, Yuri, vacuum
|
At 19:10 Frank called us that vacuum in sections 08 and 10 got worse by about 1.5 times. There is a possible danger that vacuum valves can get closed if rest gas pressure is above the set treshhold.
Nikos warmed the cryostat by 0.5 degrees from 129.0 K to 129.5 K and the pressure became better than before. We cooled the system in steps of 0.1 degress down to 129.1 K and again observed the pressure rise.
We think we can stay with the present conditions. However, the pressure shall be monitored not to hit the treshhold. |
Tue Mar 1 19:41:24 2022, PM, LV, target temperature walkthrough
|
A target temperature walkthrough has been initiated at 20:41 since the target density at S1 had slightly decreased (with ~0.1-0.2)
Current temprature 116K
set to 126K at 20:41
set to 95K at 20:47:30
set to 108.5K at 21:01:30, at this temperature was a sweetspot observerd for target density.
set to 109.7 at 21:08:30
set to 110K at 21:13:30 - we keep at this value for a while. the values at S1 are changing between 2.2-2.9e-8 |
Tue Feb 20 08:41:08 2024, OF, AG, still no beam CRYRING
|
We have mosty empty injections into CRYRING. Only sporadically the beam with good intensity is injected.
Michael Lestinsky is currently working on the problem. |
Mon Jun 16 11:12:22 2025, JG, AK, AR, EH, run 83 8x
|
12:15 restarted measurement with target - Run 83
same settings as for runs 76, 77 etc
ROOT histograms NOT zeroed
Beam at 8e8, target density at 1.5e13, scintillator @ 0 deg. peak rate 5000
status screenshots attached
15:15: Checks all ok, peaks are peaky (attatchment 8)
16:45 Checks all ok.
17:45 Checks all ok. IMP Froze and has been restarted. Peaks good. Light turned off iin cave.
18:40: Checks all ok. Target great at 1e13.
22:20 Checks done - all okay except aida green-to-red was not working, but still writing data to disk. Carlo trying to figure it out now. All other checks were okay. Daedalus crashed, restarted and target still at 1e13. |
Tue May 27 15:18:46 2025, JG, CN, JM, run 24 7x
|
Run 24 running
27/05/2025
We start a new run with real data taking condititon: beam is ok, target density is 5e11 cm-2, detectors are moving in-out periodically.
Cooler voltage setpoint 1128.55 V.
Beam energy = 1.99 MeV/u (from HKR)
Attachment 1 - beamcalc with set values
Attachment 7 - beamcalc with actual values
Left arm at 18.86 mm
Right arm IN at 83.69 mm (OUT 37.56 mm)
vertical beam position 0.0 mm
horizontal beam position -3.5mm
Beam intensity ~2e+7 particles.
Target density ~5e11 at/cm2
Target temperatures: T1=31.5 K T2=35.1 K
Beam cycle set to 10 seconds.
17:32 all checks OK
17:35 target density jumped to at 9e11
19:30 all checks OK (spectra attached)
19:45 target density drops to 3.5E11
20:20 target density jumps to 7e11
21:30 all checks OK
22:50 all checks OK
|
Tue Mar 1 06:04:04 2022, SHB, MS, positions
|
just FYI: current positions saved in files are x=1000 and y=-750. this information is good in case of crash.
|
Sun Feb 27 20:19:06 2022, Rui-Jiu Chen, Yuri, open the valves of target.
|
|
Tue Mar 1 10:35:59 2022, MS, SHB, next run on tape server tab
|
old potentiometer position 19.1 mm
new run number: 83
new potentiometer position : 27.58 mm
|
Wed Mar 2 09:38:50 2022, Spillmann, Uwe, ion source restarted
|
detector position
out: 23.1mm
in: 67.4mm
tape: next file
gas jet S1: 2.0-2.2 ** -8
|
Sun Feb 27 15:41:33 2022, Rui-Jiu Chen, Yuri, current status 13x
|
16:38 change target temperature from 95 k to 140 k.
16:48 change target temperature from 140k to 95k.
Ring current ~5.62e7 particles/s
SW3
- Merger OK
- Screenshot uploaded
- Data rate : 1190 kbytes/s
SW4
- current plot uploaded. 3.25 uA.
SW2
- T OK
- system wide checks OK
- Check statistics tab ok
- Spectra ok
SW5
4 plots uploaded |
Sun Feb 27 17:00:45 2022, Rui-Jiu Chen, Yuri, current status 13x
|
Ring current ~7.76e7 particles/s
SW3
- Merger OK
- Screenshot uploaded
- Data rate : 1664 kbytes/s
SW4
- current plot uploaded. 3.25 uA.
SW2
- T OK
- system wide checks OK
- Check statistics tab ok
- Spectra ok
SW5
4 plots uploaded |
Mon Feb 28 07:35:51 2022, JG, current logger crashed
|
The current logger did crash in the evening of 25.02. and stopped logging since then, it seems.
I restarted it now (28.02. 8:30).
Seems to run stable for now.
|
Wed Feb 23 22:29:50 2022, PE, EM, CB (remotely), check - 23:30
|
Motor position ok
Data rate: 1030kbytes/s
T ok
System wide check ok
plots uploaded
DAQ crashed soon afterwards |
Wed Feb 23 21:27:29 2022, TD, CN, check 11x
|
Motor position ok
Data rate: 1030kbytes/s
T ok
System wide check ok
plots uploaded
|
Tue Mar 1 10:43:36 2022, MS, SHB, check 11x
|
'Check Clock Status', 'Check ADC Calibration' and 'Check the White rabbit decoder status': same
|
Wed Feb 23 19:22:55 2022, CN, TD, check 10x
|
- Motor checked , OK
SW3
- Merger OK
- Screenshot uploaded
- Data rate : 755 kbytes/s
SW4
- current plot uploaded
SW2
- T OK
- system wide check OK
- Statistics ok
- Spectra ok
SW5
4 plots uploaded
|
Thu Feb 24 08:15:23 2022, JG, MS, check 13x
|
Beam is still beeing tuned. Target is off.
There is a problem with ADC calibration of aida5: see entry https://elog.ph.ed.ac.uk/CARME/268
- Motor on manual
SW3
- Merger OK
- Screenshot uploaded
- Data rate : ??? kbytes/s
SW4
- current plot uploaded
SW2
- T OK
- system wide check OK (ADC calibration test for AIDA5 failed, see above)
- Statistics ok
- Spectra ok
SW5
4 plots uploaded
|
Thu Feb 24 09:43:16 2022, JG, MS, check 13x
|
Beam is still beeing tuned. Target is off.
- Motor on manual
SW3
- Merger OK
- Screenshot uploaded
- Data rate : 947 kbytes/s
SW4
- current plot uploaded
SW2
- T OK
- system wide checks OK
- Spectra ok
SW5
4 plots uploaded
|
Thu Feb 24 22:45:08 2022, Jordan, George, Rui-Jiu Chen, check 14x
|
- Motor fully out position.
SW3
- Merger OK
- Screenshot uploaded
- Data rate : 236 kbytes/s
SW4
- current plot uploaded
SW2
- T OK
- system wide checks OK
- Check statistics tab ok
- Spectra ok
SW5
4 plots uploaded
|