ID |
Date |
Author |
Subject |
336
|
Mon Feb 28 23:54:02 2022 |
JM, EM | Current Status, Temperature cycle |
00:51
Temperature setpoint = 116 K
Detector position IN potentionmeter = 34.89mm
Rutherford rate fluctuates, consistently above 100 counts peak height
Merger OK
Data rate = 1600 kb/sec
Leakage current = 3.235 uA
Temperatures OK
System checks OK - wr fails
Base Current Difference
aida01 fault 0xab60 : 0xab8c : 44
aida02 fault 0x88d3 : 0x88fe : 43
aida03 fault 0x23aa : 0x23d6 : 44
aida04 fault 0x15d7 : 0x1603 : 44
aida05 fault 0x2f03 : 0x2f0f : 12
White Rabbit error counter test result: Passed 0, Failed 5
Understand the status reports as follows:-
Status bit 3 : White Rabbit decoder detected an error in the received data
Status bit 2 : Firmware registered WR error, no reload of Timestamp
Status bit 0 : White Rabbit decoder reports uncertain of Timestamp information from WR
Avg ring pressure = 4.4 E-10 mbar
01:18
Rutherford rate showed sustained drop to below 10 counts peak level. E4 was also consistently down, fluctuating in the low -9 mbar range compared to -8 mbar range previously.
Temperature increased to 125 K
01:39
Completed increase to 125k, drop to 95k and back to 116k. Rate has improved somewhat, however is still lower than before. Will monitor and see if any further change in temperature helps.
01:48
E4 pressures and rutherford rate remain low ~40 counts peak height. Decreasing temperature in 1k steps to see if any improvement.
02:05
Rates still low at decreased temperature. Setting to 140 K for 15-20 mins and then bringing back down.
02:36
Temperature brought back down, optimum temperature appears to be 118 K. E4 ~ 3E-9 mbar and rutherford rate is back around 100 counts peak heught. |
Attachment 1: 2022-03-01_00-57-44-Exrate.png
|
|
Attachment 2: 2022-03-01_00-58-41-ExTotal.png
|
|
Attachment 3: 2022-03-01_00-58-14-EyTotal.png
|
|
335
|
Mon Feb 28 22:34:51 2022 |
JM, EM | Current status |
23:35
Temperature setpoint = 116 K
Detector position IN, potentiometer reads 34.89 mm
Rutherford rate fluctuates however is consistently aboe 100 counts peak height
Merger OK
Data rate = 1600 kb/sec
Leakage current = 3.23 uA
Temperatures OK
System checks OK - wr attached
Base Current Difference
aida01 fault 0xab60 : 0xab8c : 44
aida02 fault 0x88d3 : 0x88fe : 43
aida03 fault 0x23aa : 0x23d6 : 44
aida04 fault 0x15d7 : 0x1603 : 44
aida05 fault 0x2f03 : 0x2f0f : 12
White Rabbit error counter test result: Passed 0, Failed 5
Understand the status reports as follows:-
Status bit 3 : White Rabbit decoder detected an error in the received data
Status bit 2 : Firmware registered WR error, no reload of Timestamp
Status bit 0 : White Rabbit decoder reports uncertain of Timestamp information from WR
|
Attachment 1: 2022-02-28_23-40-14-xyTotal.png
|
|
Attachment 2: 2022-02-28_23-39-56-Exrate.png
|
|
Attachment 3: 2022-02-28_23-39-26-goodEvents.png
|
|
Attachment 4: 2022-02-28_23-38-58-correlation8.png
|
|
Attachment 5: 2022-02-28_23-38-31-ADCitems.png
|
|
334
|
Mon Feb 28 14:47:52 2022 |
CB, TD | Monday 28 February 15:00-23:00 |
15.51 1.8.W spectra 20ms, 2ms, 200us, 20us FSR - attachments 1-8
15.55 Lost control of motors - moving DSSSDs out
15.56 new run number 79
ignore run number 80
17:58 new run number 81
CB sets motion cycle from 20.28mm to 64.36mm
Observe a second, higher energy peak during the part of the cycle where the DSSSD is moved out - see attachments 9-10
Peak appears only when moving out. Does not appear when moving in/out manually on beam storage plateau. Does not appear when moving in synched with ring, waiting less than the storage time, and moving out.
All seems to indicate it is due to beam injection and not moving out fast enough. Very weak halo piling up? Should be clear in the data depending on rate / strips affected.
18.45 new run number 82
DSSSD position fixed 34.89mm
22.10 system wide checks OK *except* WR decoder status
Base Current Difference
aida01 fault 0xab60 : 0xab8c : 44
aida02 fault 0x88d3 : 0x88fe : 43
aida03 fault 0x23aa : 0x23d6 : 44
aida04 fault 0x15d7 : 0x1603 : 44
aida05 fault 0x2f03 : 0x2f0f : 12
White Rabbit error counter test result: Passed 0, Failed 5
Understand the status reports as follows:-
Status bit 3 : White Rabbit decoder detected an error in the received data
Status bit 2 : Firmware registered WR error, no reload of Timestamp
Status bit 0 : White Rabbit decoder reports uncertain of Timestamp information from WR
FEE64 temperatures OK - attachment 11
ADC data item stats OK - attachment 12
merger, tape server and console OK - no merger error messages since startup - attachments 13-15
DSSSD bias -100V leakage current-3.2360uA
run82 - integrated x & y strip energy spectra - attachments 16-17 |
Attachment 1: Screenshot_from_2022-02-28_15-51-42.png
|
|
Attachment 2: Screenshot_from_2022-02-28_15-51-27.png
|
|
Attachment 3: Screenshot_from_2022-02-28_15-50-56.png
|
|
Attachment 4: Screenshot_from_2022-02-28_15-50-44.png
|
|
Attachment 5: Screenshot_from_2022-02-28_15-50-26.png
|
|
Attachment 6: Screenshot_from_2022-02-28_15-50-08.png
|
|
Attachment 7: Screenshot_from_2022-02-28_15-49-44.png
|
|
Attachment 8: Screenshot_from_2022-02-28_15-49-28.png
|
|
Attachment 9: Screenshot_from_2022-02-28_18-03-13.png
|
|
Attachment 10: Screenshot_from_2022-02-28_18-03-20.png
|
|
Attachment 11: Screenshot_from_2022-02-28_22-13-42.png
|
|
Attachment 12: Screenshot_from_2022-02-28_22-14-12.png
|
|
Attachment 13: Screenshot_from_2022-02-28_22-15-31.png
|
|
Attachment 14: Screenshot_from_2022-02-28_22-15-22.png
|
|
Attachment 15: Screenshot_from_2022-02-28_22-15-16.png
|
|
Attachment 16: Screenshot_from_2022-02-28_22-18-23.png
|
|
Attachment 17: Screenshot_from_2022-02-28_22-18-01.png
|
|
333
|
Mon Feb 28 14:42:48 2022 |
CB, TD | Cryostat set to 115K |
Cryostat set to 115K |
332
|
Mon Feb 28 14:38:15 2022 |
TD | NewMerger statistics |
Screenshots of all NewMerger statistics |
Attachment 1: Screenshot_from_2022-02-28_15-38-04.png
|
|
Attachment 2: Screenshot_from_2022-02-28_15-37-57.png
|
|
Attachment 3: Screenshot_from_2022-02-28_15-37-52.png
|
|
Attachment 4: Screenshot_from_2022-02-28_15-37-44.png
|
|
Attachment 5: Screenshot_from_2022-02-28_15-37-32.png
|
|
Attachment 6: Screenshot_from_2022-02-28_15-37-24.png
|
|
Attachment 7: Screenshot_from_2022-02-28_15-37-10.png
|
|
Attachment 8: Screenshot_from_2022-02-28_15-37-03.png
|
|
Attachment 9: Screenshot_from_2022-02-28_15-36-55.png
|
|
Attachment 10: Screenshot_from_2022-02-28_15-36-48.png
|
|
Attachment 11: Screenshot_from_2022-02-28_15-36-39.png
|
|
Attachment 12: Screenshot_from_2022-02-28_15-36-31.png
|
|
Attachment 13: Screenshot_from_2022-02-28_15-36-23.png
|
|
Attachment 14: Screenshot_from_2022-02-28_15-36-16.png
|
|
Attachment 15: Screenshot_from_2022-02-28_15-36-07.png
|
|
Attachment 16: Screenshot_from_2022-02-28_15-35-59.png
|
|
Attachment 17: Screenshot_from_2022-02-28_15-35-51.png
|
|
Attachment 18: Screenshot_from_2022-02-28_15-35-42.png
|
|
Attachment 19: Screenshot_from_2022-02-28_15-35-36.png
|
|
Attachment 20: Screenshot_from_2022-02-28_15-35-26.png
|
|
Attachment 21: Screenshot_from_2022-02-28_15-35-14.png
|
|
Attachment 22: Screenshot_from_2022-02-28_15-35-09.png
|
|
Attachment 23: Screenshot_from_2022-02-28_15-34-52.png
|
|
Attachment 24: Screenshot_from_2022-02-28_15-34-47.png
|
|
Attachment 25: Screenshot_from_2022-02-28_15-34-42.png
|
|
Attachment 26: Screenshot_from_2022-02-28_15-34-35.png
|
|
Attachment 27: Screenshot_from_2022-02-28_15-34-28.png
|
|
Attachment 28: Screenshot_from_2022-02-28_15-34-20.png
|
|
Attachment 29: Screenshot_from_2022-02-28_15-34-12.png
|
|
Attachment 30: Screenshot_from_2022-02-28_15-34-03.png
|
|
Attachment 31: Screenshot_from_2022-02-28_15-33-50.png
|
|
Attachment 32: Screenshot_from_2022-02-28_15-33-45.png
|
|
Attachment 33: Screenshot_from_2022-02-28_15-33-39.png
|
|
Attachment 34: Screenshot_from_2022-02-28_15-33-31.png
|
|
Attachment 35: Screenshot_from_2022-02-28_15-33-24.png
|
|
Attachment 36: Screenshot_from_2022-02-28_15-33-15.png
|
|
Attachment 37: Screenshot_from_2022-02-28_15-33-07.png
|
|
331
|
Mon Feb 28 13:56:02 2022 |
JG, CB | Temperature cycle to 125K |
14:45
Rutherford rate was decreased significantly for longer period.
Temperature increased to 125 K
No large increase in chamber pressure observed.
14:55
Temperature setpoint back to 110 K.
Rutherford rate has increased. Peak height 3*10^1. |
330
|
Mon Feb 28 13:16:39 2022 |
JG, AK, CB | Current status |
14:16
beam intensity at injection: 7e7 ions
Temperature setpoint = 110 k
Rutherford rates shaky, peak max at ~ 1x10^2
Merger OK
Data rate ~ 1500 kb/sec
Ring avg pressure ~ 2.3E-10 mbar
Temperatures OK
System checks OK (wr fail)
Leakage current ~ 3.23 uA |
Attachment 1: Screenshot_from_2022-02-28_14-16-00.png
|
|
Attachment 2: Screenshot_from_2022-02-28_14-15-43.png
|
|
Attachment 3: Screenshot_from_2022-02-28_14-15-30.png
|
|
Attachment 4: Screenshot_from_2022-02-28_14-15-10.png
|
|
Attachment 5: Screenshot_from_2022-02-28_14-14-29.png
|
|
Attachment 6: Screenshot_from_2022-02-28_14-14-22.png
|
|
Attachment 7: Screenshot_from_2022-02-28_14-14-14.png
|
|
Attachment 8: Screenshot_from_2022-02-28_14-13-24.png
|
|
329
|
Mon Feb 28 11:57:22 2022 |
JG, AK, CB | Current status |
12:55
beam intensity at injection: 9e7 ions
Temperature setpoint = 110 k
Rutherford rates shaky, peak max at ~ 3x10^2
Merger OK
Data rate ~ 1400 kb/sec
Ring avg pressure ~ 2.8E-10 mbar
Temperatures OK
System checks OK (wr fail)
Leakage current ~ 3.22 uA |
Attachment 1: Screenshot_from_2022-02-28_12-56-50.png
|
|
Attachment 2: Screenshot_from_2022-02-28_12-56-40.png
|
|
Attachment 3: Screenshot_from_2022-02-28_12-56-29.png
|
|
Attachment 4: Screenshot_from_2022-02-28_12-56-16.png
|
|
Attachment 5: Screenshot_from_2022-02-28_12-55-36.png
|
|
Attachment 6: Screenshot_from_2022-02-28_12-55-08.png
|
|
Attachment 7: Screenshot_from_2022-02-28_12-54-54.png
|
|
Attachment 8: Screenshot_from_2022-02-28_12-54-33.png
|
|
328
|
Mon Feb 28 10:55:48 2022 |
JG, US | Current status |
11:55
beam intensity at injection: 8e7 ions
Temperature setpoint = 110 k
Rutherford rates shaky, peak max at ~ 3x10^2
Merger OK
Data rate ~ 1600 kb/sec
Ring avg pressure ~ 2.7E-10 mbar
Temperatures OK
System checks OK - wr fail attached
Leakage current ~ 3.22 uA |
Attachment 1: Screenshot_from_2022-02-28_11-57-17.png
|
|
Attachment 2: Screenshot_from_2022-02-28_11-57-04.png
|
|
Attachment 3: Screenshot_from_2022-02-28_11-56-48.png
|
|
Attachment 4: Screenshot_from_2022-02-28_11-54-34.png
|
|
Attachment 5: Screenshot_from_2022-02-28_11-53-25.png
|
|
Attachment 6: Screenshot_from_2022-02-28_11-52-21.png
|
|
Attachment 7: Screenshot_from_2022-02-28_11-52-14.png
|
|
Attachment 8: Screenshot_from_2022-02-28_11-51-06.png
|
|
327
|
Mon Feb 28 09:31:48 2022 |
JG, AK, CB | Current status |
10:35
beam intensity at injection: 1e8 ions
Temperature setpoint = 110 k
Rutherford rates shaky, peak max at ~ 3x10^2
Merger OK
Data rate ~ 1200 kb/sec
Ring avg pressure ~ 2.7E-10 mbar
Temperatures OK
System checks OK - wr fail attached
Leakage current ~ 3.22 uA |
Attachment 1: Screenshot_from_2022-02-28_10-31-27.png
|
|
Attachment 2: Screenshot_from_2022-02-28_10-31-16.png
|
|
Attachment 3: Screenshot_from_2022-02-28_10-31-06.png
|
|
Attachment 4: Screenshot_from_2022-02-28_10-30-49.png
|
|
Attachment 5: Screenshot_from_2022-02-28_10-30-30.png
|
|
Attachment 6: Screenshot_from_2022-02-28_10-30-24.png
|
|
Attachment 7: Screenshot_from_2022-02-28_10-30-00.png
|
|
Attachment 8: Screenshot_from_2022-02-28_10-29-26.png
|
|
326
|
Mon Feb 28 08:36:35 2022 |
JG, AK, CB | Current status |
09:35
beam intensity at injection: 8.2e7 ions
Temperature setpoint = 110 k
Rutherford rates shaky, peak max at ~ 3x10^2
Merger OK
Data rate ~ 1400 kb/sec
Ring avg pressure ~ 2.7E-10 mbar
Temperatures OK
System checks OK - wr fail attached
Leakage current ~ 3.22 uA |
Attachment 1: Screenshot_from_2022-02-28_09-36-05.png
|
|
Attachment 2: Screenshot_from_2022-02-28_09-35-56.png
|
|
Attachment 3: Screenshot_from_2022-02-28_09-35-35.png
|
|
Attachment 4: Screenshot_from_2022-02-28_09-35-18.png
|
|
Attachment 5: Screenshot_from_2022-02-28_09-35-07.png
|
|
Attachment 6: Screenshot_from_2022-02-28_09-34-21.png
|
|
Attachment 7: Screenshot_from_2022-02-28_09-34-06.png
|
|
Attachment 8: Screenshot_from_2022-02-28_09-33-48.png
|
|
325
|
Mon Feb 28 07:35:51 2022 |
JG | current logger crashed |
The current logger did crash in the evening of 25.02. and stopped logging since then, it seems.
I restarted it now (28.02. 8:30).
Seems to run stable for now.
|
Attachment 1: Screenshot_from_2022-02-28_08-38-35.png
|
|
324
|
Mon Feb 28 07:31:25 2022 |
JG, AK | Current status |
08:30
Temperature setpoint = 110 k
Rutherford rates shaky, peak max at ~ 3x10^2
Merger OK
Data rate ~ 1500 kb/sec
Ring avg pressure ~ 2.7E-10 mbar
Temperatures OK
System checks OK - wr fail attached
Leakage current ~ 3.22 uA |
Attachment 1: Screenshot_from_2022-02-28_08-30-34.png
|
|
Attachment 2: Screenshot_from_2022-02-28_08-30-13.png
|
|
Attachment 3: Screenshot_from_2022-02-28_08-29-59.png
|
|
Attachment 4: Screenshot_from_2022-02-28_08-29-44.png
|
|
Attachment 5: Screenshot_from_2022-02-28_08-29-28.png
|
|
Attachment 6: Screenshot_from_2022-02-28_08-29-17.png
|
|
Attachment 7: Screenshot_from_2022-02-28_08-29-10.png
|
|
Attachment 8: Screenshot_from_2022-02-28_08-29-04.png
|
|
323
|
Mon Feb 28 06:12:58 2022 |
JG, AK, US | Current status |
07:20
Temperature setpoint = 110 k
Rutherford rates shaky, peak max at ~ 3x10^2
Merger OK
Data rate ~ 1200 kb/sec
Ring avg pressure ~ 2.5E-10 mbar
Temperatures OK
System checks OK - wr fail attached
Leakage current ~ 3.222 uA |
Attachment 1: Screenshot_from_2022-02-28_07-16-18.png
|
|
Attachment 2: Screenshot_from_2022-02-28_07-16-02.png
|
|
Attachment 3: Screenshot_from_2022-02-28_07-15-49.png
|
|
Attachment 4: Screenshot_from_2022-02-28_07-15-28.png
|
|
Attachment 5: Screenshot_from_2022-02-28_07-12-06.png
|
|
Attachment 6: Screenshot_from_2022-02-28_07-11-59.png
|
|
Attachment 7: Screenshot_from_2022-02-28_07-11-48.png
|
|
Attachment 8: Screenshot_from_2022-02-28_07-17-27.png
|
|
322
|
Mon Feb 28 05:04:47 2022 |
JM, OF | Temperature cycle to 125K |
06:01
Rutherford rate was decreased compared to previous values. Max rate ~ 50 counts for the peak, average ~20 counts.
Temperature increased to 125 K
No large increase in chamber pressure observed.
06:25
Temperature setpoint back to 110 K.
Rutherford rate has increased, however is quite variable. Peak height 3*10^1 to 10^2 range.
06:54
Setpoint = 110 K
Ruthrford rate has stabilised around 7*10^1 to 10^2 peak height.
Merger OK
Data rate ~ 1300 kb/sec
Leakage current ~ 3.22 uA
Temperatures OK
System checks OK |
Attachment 1: 2022-02-28_06-30-39-Exrate.png
|
|
321
|
Mon Feb 28 04:14:26 2022 |
JM, OF | Current status |
05:20
Temperature setpoint = 110 k
Rates are stable however are slightly lower than previous. Min peak height ~40 counts, max ~ 10^2.
Merger OK
Data rate ~ 1200 kb/sec
Ring avg pressure ~ 2.9E-10 mbar
Temperatures OK
System checks OK - wr fail attached
Leakage current ~ 3.222 uA |
Attachment 1: 2022-02-28_05-20-11-correlation8.png
|
|
Attachment 2: 2022-02-28_05-19-44-ADCitems.png
|
|
Attachment 3: 2022-02-28_05-19-19-goodEvents.png
|
|
Attachment 4: 2022-02-28_05-18-55-wr.png
|
|
Attachment 5: 2022-02-28_05-18-13-Exrate.png
|
|
Attachment 6: 2022-02-28_05-21-31-ExTotal.png
|
|
Attachment 7: 2022-02-28_05-22-26-xyTotal.png
|
|
Attachment 8: 20220228_052350.jpg
|
|
Attachment 9: 20220228_052326.jpg
|
|
320
|
Mon Feb 28 03:16:37 2022 |
JM, OF | Current status |
04:24
Temperature setpoint 110 K
Rates appeared stable throughout the hour ~10^2 peak height. Last 5 minutes rutherford peak height appears reduced, cycling from 10^1 to 10^2. If this continues with sustained low density, temperature will be cycled to 125 K and back down.
Merger OK
Data rate = 1300 kb/sec
Ring avg pressure = 3.1E-10 mbar
Temperatures OK
System checks OK - wr fail attached
Leakage current ~ 3.228 uA
04:33
Rutherford rate appears to have increased and stabilised again around 10^2 peak height. |
Attachment 1: 2022-02-28_04-23-06-rates.png
|
|
Attachment 2: 2022-02-28_04-22-28-goodEvents.png
|
|
Attachment 3: 2022-02-28_04-22-05-correlation8.png
|
|
Attachment 4: 2022-02-28_04-21-39-ADCitems.png
|
|
Attachment 5: 2022-02-28_04-21-17-wr.png
|
|
Attachment 6: 20220228_042449.jpg
|
|
319
|
Mon Feb 28 02:16:00 2022 |
JM, OF | Current status |
03:21
Temperature setpoint 110 K
Rutherford rate stable. Min peak height ~ 10^2 counts, max ~ 3*10^2 counts.
Temperatures OK
System checks OK - wr attached
Merger OK
Data rate ~ 1500 kb/sec
Leakage current ~ 3.228 uA
Ring vacuum stable, Avg = 3.1E-10 mbar
E1 pump current = 2.5 A |
Attachment 1: 2022-02-28_03-11-52-Rates_1.png
|
|
Attachment 2: 2022-02-28_03-12-28-ExTotal.png
|
|
Attachment 3: 2022-02-28_03-15-07-xyTotal.png
|
|
Attachment 4: 2022-02-28_03-17-43-wr.png
|
|
Attachment 5: 2022-02-28_03-19-41-leakage-current.png
|
|
Attachment 6: 20220228_032156.jpg
|
|
318
|
Mon Feb 28 01:16:02 2022 |
JM, OF | Temperature decrease 115K to 110K |
02:15
Density remains stable at 155 K
Temperature setpoint decreased by 1K. Aim to get to 110 K to see if higher stable density can be achieved.
Spike in YR pressures observed as temperature was decreased, still look OK. Will leave to settle for a while. T = 114K.
Rates remain stable at ~ 10^2 peak height level.
02:33
Pressures stabilised
Setpoint to 113 K.
02:40
No pressure spike observed after decrease
Setpoint to 112 K
02:46
No pressure spike observed after decrease
Setpoint to 111 K
Pressure spike observed in YR pressures (smaller than last) - give time to recover.
03:00
Setpoint to 110 K
No pressure spike observed.
Rutherford rate peak height remains stable at ~ 10^2 . Perhaps peak height minimum is consistently higher than before, difficult to say.
Attachment 1 - 115 K
Attachment 2 - spike 1
Attachment 3 - spike 2
All pressure stable now |
Attachment 1: 20220228_021455.jpg
|
|
Attachment 2: 20220228_023832.jpg
|
|
Attachment 3: 20220228_025416.jpg
|
|
317
|
Mon Feb 28 00:24:05 2022 |
JM, OF | Current status |
01:23
Temperature setpoint = 115 k
Rutherford rates still appears stable. Max peak ~10^2 counts, min peak ~50 counts per 20 seconds. Greater fluctuations in YR07 plot however do not appear too high, peaks coincide with sustained higher rutherford counts ~10^2 counts most of the time.
Ring Avg pressure 3.1 E-10 mbar
Ring current ~ 6E7
Temperatures OK
System wide checks OK - wr fails is attached
Merger OK
Data rate ~ 1400 kb/sec
Leakage current ~ 3.23 uA |
Attachment 1: 2022-02-28_01-23-34-rates.png
|
|
Attachment 2: 2022-02-28_01-27-01-wr.png
|
|
Attachment 3: 2022-02-28_01-27-22-correlation8.png
|
|
Attachment 4: 2022-02-28_01-27-53-goodEvents.png
|
|
Attachment 5: 2022-02-28_01-28-17-ADCitems.png
|
|
Attachment 6: 20220228_013033.jpg
|
|
Attachment 7: 20220228_013020.jpg
|
|