Entry  Fri Feb 25 00:00:40 2022, Rui-Jiu Chen, Alex, Check 14x
There are some problems with ion source.  No beam in CRYING.

Motor fully out position.

SW3
Entry  Thu Feb 24 23:15:25 2022, Rui-Jiu Chen, Alex, Problems with ion souce. 
 
Entry  Thu Feb 24 22:45:08 2022, Jordan, George, Rui-Jiu Chen, check 14x
- Motor fully out position.

SW3

- Merger OK
Entry  Thu Feb 24 14:31:25 2022, JM, ML, CN, Beam Tuning Run 76 6x
15:30

1.5 MeV/u beam currently being tuned

Target is ON, setpoint = 135 K
Entry  Thu Feb 24 09:43:16 2022, JG, MS, check 13x
Beam is still beeing tuned. Target is off.

 

- Motor on manual
Entry  Thu Feb 24 08:30:36 2022, JG, MS, AIDA5 calibration test failed - solved Screenshot_from_2022-02-24_09-09-36.pngScreenshot_from_2022-02-24_09-29-24.png
UPDATE: THE PROBLEM IS SOLVED FOR NOW:

Doing the calib for the 5th time eventually worked.

------------
Entry  Thu Feb 24 08:15:23 2022, JG, MS, check 13x
Beam is still beeing tuned. Target is off.

There is a problem with ADC calibration of aida5: see entry https://elog.ph.ed.ac.uk/CARME/268

 
Entry  Thu Feb 24 07:25:53 2022, OH (Remote), Recover of system after crash 
08:00 Woke up to message from Carlo explaining the server had crashed.
      Anydesked into the machine.
      Merger was showing just data transfer it was not showing Transfer => Merger
Entry  Thu Feb 24 05:09:47 2022, CB, PE, EM, Inlet valve at target closed + problems with turbopump 
The turbo pump E1 is continuing to draw too much current and the rotation frequency has steadily decreased from 817 Hz at the beginning of the night
shift to 800 Hz now. The frequency recovered after the temperature was increased.

Both of the valves (inlet and dump) have been closed to improve the vacuum in the ring.
Entry  Thu Feb 24 04:17:35 2022, CB, TD (remotely), MIDAS DAQ no longer working Bad_Time_2022-02-24_04-34-12.pngBadTime_WRTime_2022-02-24_04-34-53.png
DAQ server crashed around 24:00

Rebooted server but could not could not rescue remotely - could not contact raspberry pi in control of FEE bias.

Entered cave, rebooted raspberry pi. Would not accept remote connections.
Entry  Wed Feb 23 22:29:50 2022, PE, EM, CB (remotely), check - 23:30 
Motor position ok

Data rate: 1030kbytes/s

T ok
Entry  Wed Feb 23 21:27:29 2022, TD, CN, check  11x
Motor position ok

Data rate: 1030kbytes/s

T ok
Entry  Wed Feb 23 20:52:56 2022, CN, TD, System wide checks 11x

Attachments 1-5 aida01-aida05 options
Entry  Wed Feb 23 20:06:43 2022, TD CN, E141 kinematics E141_kinematics.txt

Assuming DSSSD is 1000um thick we can expect to observe protons for E_lab=11MeV as follows
Entry  Wed Feb 23 19:22:55 2022, CN, TD, check 10x
 

- Motor checked , OK

SW3
Entry  Wed Feb 23 18:58:12 2022, TD CN, Wednesday 23 February 15.00-23.00 shift 6x


Assorted screenshots of the CARME, CRYRING and gas jet target control systems in operation
Entry  Wed Feb 23 16:57:35 2022, CB, CN, Optimising motor motion 
Optimised motor motion during run R58

Moved 2 mm in (20.3 potentiometer)

29.47 potentiometer
Entry  Wed Feb 23 10:56:06 2022, Laszlo, Thanassis, Current status 10x
11:55
Temps OK
System Check OK
Entry  Wed Feb 23 09:50:19 2022, Laszlo, Thanassis, Moving detector in 
We are moving the detector in run 56
Entry  Wed Feb 23 08:58:30 2022, Laszlo, Thanassis, Current status 10x
10:00
Temps OK
System Check OK