  CARME, Page 23 of 34  ELOG logo
  ID Date Author Subject
  226   Tue Feb 22 04:09:28 2022 JM, CB, LV, PM, AKBeam ON, Target ON Run 54 - first event at 10MeV !

05:00

Beam ON ~2E6 pps, still fluctates between 2e6 and 6e6 (like a step function)

Target ON and open to the ring

YR09xxx ETarget ~1.8e-10

Target E4 inlet pressure 8.3E-9 mbar

Dump S3 ~ 6.8E-10 mbar

Nozzle temperature 150 K

Run 54 started, monitoring code restarted.

Attachment 1: Screenshot_from_2022-02-22_05-07-47.png
Screenshot_from_2022-02-22_05-07-47.png
Attachment 2: Screenshot_from_2022-02-22_05-07-33.png
Screenshot_from_2022-02-22_05-07-33.png
Attachment 3: Screenshot_from_2022-02-22_05-07-19.png
Screenshot_from_2022-02-22_05-07-19.png
Attachment 4: Screenshot_from_2022-02-22_05-06-58.png
Screenshot_from_2022-02-22_05-06-58.png
Attachment 5: Screenshot_from_2022-02-22_05-06-30.png
Screenshot_from_2022-02-22_05-06-30.png
Attachment 6: Screenshot_from_2022-02-22_05-06-19.png
Screenshot_from_2022-02-22_05-06-19.png
Attachment 7: Screenshot_from_2022-02-22_05-06-06.png
Screenshot_from_2022-02-22_05-06-06.png
Attachment 8: Screenshot_from_2022-02-22_05-05-40.png
Screenshot_from_2022-02-22_05-05-40.png
Attachment 9: Screenshot_from_2022-02-22_05-05-30.png
Screenshot_from_2022-02-22_05-05-30.png
Attachment 10: Screenshot_from_2022-02-22_05-05-11.png
Screenshot_from_2022-02-22_05-05-11.png
Attachment 11: Screenshot_from_2022-02-22_05-04-25.png
Screenshot_from_2022-02-22_05-04-25.png
  225   Tue Feb 22 03:05:06 2022 JM, CB, LV, PM, AKBeam ON, Target ON Run 54

04:00

Beam ON ~5.5E6 pps, but it fluctates between 2e6 and 6e6 (like a step function) in about each 5-10min

Target ON and open to the ring

YR09xxx ETarget ~1.8e-10

Target E4 inlet pressure 8.4E-9 mbar

Dump S3 ~ 7.0E-10 mbar

Nozzle temperature 150 K

Run 54 started, monitoring code restarted.

Attachment 1: Screenshot_from_2022-02-22_04-02-25.png
Screenshot_from_2022-02-22_04-02-25.png
Attachment 2: Screenshot_from_2022-02-22_04-03-08.png
Screenshot_from_2022-02-22_04-03-08.png
Attachment 3: Screenshot_from_2022-02-22_04-03-44.png
Screenshot_from_2022-02-22_04-03-44.png
Attachment 4: Screenshot_from_2022-02-22_04-03-24.png
Screenshot_from_2022-02-22_04-03-24.png
Attachment 5: Screenshot_from_2022-02-22_04-04-28.png
Screenshot_from_2022-02-22_04-04-28.png
Attachment 6: Screenshot_from_2022-02-22_04-04-10.png
Screenshot_from_2022-02-22_04-04-10.png
Attachment 7: Screenshot_from_2022-02-22_04-03-55.png
Screenshot_from_2022-02-22_04-03-55.png
Attachment 8: Screenshot_from_2022-02-22_04-10-57.png
Screenshot_from_2022-02-22_04-10-57.png
Attachment 9: Screenshot_from_2022-02-22_04-10-37.png
Screenshot_from_2022-02-22_04-10-37.png
  224   Tue Feb 22 02:02:11 2022 JM, CB, LV, PM, AKBeam ON, Target ON Run 54

03:00

Beam ON ~7E6 pps

Target ON and open to the ring

Target E4 inlet pressure 8.5E-9 mbar

Dump S3 ~ 7.3E-10 mbar

Nozzle temperature 150 K

Run 54 started, monitoring code restarted.

Attachment 1: TapeServer2022-02-22_02-49-29.png
TapeServer2022-02-22_02-49-29.png
Attachment 2: Leakage_current2022-02-22_02-50-39.png
Leakage_current2022-02-22_02-50-39.png
Attachment 3: Temperature2022-02-22_02-52-02.png
Temperature2022-02-22_02-52-02.png
Attachment 4: Screenshot_from_2022-02-22_02-54-34.png
Screenshot_from_2022-02-22_02-54-34.png
Attachment 5: Good_events2022-02-22_02-55-14.png
Good_events2022-02-22_02-55-14.png
Attachment 6: AIDA_CorrelationScreenshot_from_2022-02-22_02-56-04.png
AIDA_CorrelationScreenshot_from_2022-02-22_02-56-04.png
Attachment 7: Spectrum_Browser2022-02-22_02-59-28.png
Spectrum_Browser2022-02-22_02-59-28.png
Attachment 8: LowEx2022-02-22_03-00-02.png
LowEx2022-02-22_03-00-02.png
Attachment 9: LowEy2022-02-22_03-00-28.png
LowEy2022-02-22_03-00-28.png
Attachment 10: LowEXYTotal2022-02-22_03-01-16.png
LowEXYTotal2022-02-22_03-01-16.png
  223   Tue Feb 22 00:32:35 2022 JM, CB, LV, PM, AKBeam ON, Target ON Run 54

01:30

Beam ON ~6E6 pps

Target ON and open to the ring

Target E4 inlet pressure 8.12E-9 mbar

Dump S3 ~ 7E-10 mbar

Nozzle temperature 150 K

1:40

Run 54 started, monitoring code restarted.

Attachment 1: 2022-02-22_01-38-53-Ex-histogram.png
2022-02-22_01-38-53-Ex-histogram.png
Attachment 2: 2022-02-22_01-38-17-XYtotal.png
2022-02-22_01-38-17-XYtotal.png
  222   Mon Feb 21 21:04:08 2022 SHB, JM, CB, OH (remotely)Schottky RF view from the beam inside
Attachment 1: pio-2022.02.21.21.54.46.895.PNG
pio-2022.02.21.21.54.46.895.PNG
  221   Mon Feb 21 20:56:51 2022 SHB, JM, CB, OH (remotely)DAQ connection for ion current

signals from ICT and CRYRADIO are now connected to AIDA2 and AIDA5 respectively. ICT is set to factor 200 and CRYRADIO to 40 for now.

 

(AIDA3 --> electron cooler)

 

Attachment 1: cry.jpg
cry.jpg
  220   Mon Feb 21 18:03:58 2022 SHB, JM, CB, OH (remotely)Info: signals on ion intensity for experiment

Currently 4 possibilities to have a look at the beam, all of them are OK to check whether there is beam or not, but some of them are better for checking absolute values.
- Schottky RF signal
- Schottky zero span signal
- CRYRING Radio (signal from BPM) --> YR12DA1R
- ICT (integrated current transformer) --> YR12DT1C


absolute measurements:

- currently the beam is at 5.5 MeV/u calibrated on the flat top. The signal of ICT before is noisy but on the flat top it is well calibrated.


relative measurements:

- The signal from CRYRING radio, has a good amplifier and is frequency independent with a nice log signal. it can be used for relative measurements

- The zero span signal of Schottky can be used, but it is not reliable for measuring the number of ions since change in the control room may change the signal level.

- Schottky RF signal can be viewed by running Launcher-App using the button "VNC Tektronix RSA". The only problem is that only one instance can run, so if in the control room someone needs it, in the container it will disappear.

 

  219   Mon Feb 21 17:26:19 2022 JM, CB, SHB, OH (remotely)Beam ON run 53

21/2/22 16:00

Call from main control room, beam is ON, probably has been for several hours judging by rate on xy total plot.

Changes made to online monitoring code by OH, include setting to only 1 DSSD, correct offsets from the pulser walkthrough, offline analysis capabilities and X/Y position correction. 

Monitoring code restarted in CARME_SORT/build_no_output

17:31 Run 50 ended, run 51 started now beam is definitely in the ring. Tried to insert span zero schottky into aida2 correlation scalar, however rate was far too high.

18:03 Removed span zero schottky signal, started new run 52.

With beam ON we noticed some missing channels in the xy total plot. Aida 1 and 2 stat totals on spectrum browser show missing channels. Asic check on both to no effect. Fees power cycled.

19:57 Started run 53. Currently waiting for beam

21:20 Beam ON

1*L plots checked for aida 1, several channels showed no data (noise)

Slow comparator LEC threshold lowered to 0x32  to aida 1, checked 1*L plots and channels are now showing lots of noise. So those channels appear to be quiet using 0x64 threshold. (attachment 3)

Threshold increased back to 0x64

22:33

System checks OK -white rabbit fails on all. ~30 seperation

Temperatures OK

Statistics within range - new scalars added for aida02 and aida05

Data being written ~300 kb/sec

Leakage current ~3.6 uA

 

00:39

System checks checks OK -white rabbit fails on all. ~42 seperation

Temperatures OK

Statistics within range with new scalars

Data being written 256 kb/sec

Leakage current ~3.615 uA

XY counts dominated by hot channels - most blue pixels are ~10 counts

 

Attachment 1: 2022-02-21_18-50-06-xyTotal.png
2022-02-21_18-50-06-xyTotal.png
Attachment 2: 2022-02-21_19-05-27-aida1-4-rate.png
2022-02-21_19-05-27-aida1-4-rate.png
Attachment 3: 2022-02-21_22-17-54-aida1-1*L-lowerThreshold.png
2022-02-21_22-17-54-aida1-1*L-lowerThreshold.png
Attachment 4: 2022-02-21_22-35-19-goodEvents.png
2022-02-21_22-35-19-goodEvents.png
Attachment 5: 2022-02-21_22-35-53-ADC-dataitems.png
2022-02-21_22-35-53-ADC-dataitems.png
Attachment 6: 2022-02-21_22-36-28-aida-correlation.png
2022-02-21_22-36-28-aida-correlation.png
Attachment 7: 2022-02-21_22-58-18-Ex-histogram.png
2022-02-21_22-58-18-Ex-histogram.png
Attachment 8: 2022-02-21_22-59-22-XY-total.png
2022-02-21_22-59-22-XY-total.png
Attachment 9: 2022-02-22_00-42-14-XY-total.png
2022-02-22_00-42-14-XY-total.png
  218   Mon Feb 21 12:10:47 2022 RSS, JGAlpha background run50

Beam OFF. Run started 20/2/22 18:42

System checck OK, except white rabbit all fail

Temperatures OK

Leakage current 3.59 uA.

potentiometer = 20.28 mm

 

11:36 OH noticed a channel in aida03 was running hot. Did an asic load check and rate returned to normal.

          Online monitor also restarted.

 

15:06 Investigating the high rate in aida03 ASIC01 channel 11.
          Looking at the waveforms it seems channel 11 is consistently different.
          Attachment 1 shows a typical waveform for it

 

Attachment 1: 220221_1506_aida03_1*W.png
220221_1506_aida03_1*W.png
  217   Mon Feb 21 10:59:48 2022 RSS, JGAlpha background run50

Beam OFF. Run started 20/2/22 18:42

System checck OK, except white rabbit all fail

Temperatures OK

Leakage current 3.59 uA.

potentiometer = 20.28 mm

 

11:36 OH noticed a channel in aida03 was running hot. Did an asic load check and rate returned to normal.

          Online monitor also restarted.

 

  216   Mon Feb 21 09:07:37 2022 RSS, JGAlpha background run50

Beam OFF. Run started 20/2/22 18:42

System checck OK, except white rabbit all fail

Temperatures OK

Leakage current 3.57 uA.

potentiometer = 20.28 mm

 

  215   Mon Feb 21 08:05:45 2022 RSS, JGAlpha background run50

Beam OFF. Run started 20/2/22 18:42

System checck OK, except white rabbit all fail

Temperatures OK

Leakage current 3.57 uA.

potentiometer = 20.28 mm

 

  214   Sun Feb 20 22:04:21 2022 JM, CBAlpha Background run 50

Beam OFF. Run started 20/2/22 18:42

Fast comparator threshold HEC set to 0xff for all fees and asics to combat high energy noise bursts.

Electron cooler scalar plugged back into aida03 ~3000 per sec.

System checck OK, except white rabbit all fail

Temperatures OK

Leakage current 3.638 uA.

Statistics rates in noraml range, aida03 slightly higher as expected with scalar.

  213   Sat Feb 19 20:08:43 2022 JM, CBBeam ON run 49

Run started 19/2/22 21:05. Beam ON

Temperatures OK

System wide checks OK - white rabbit fails on all.

Statistics are within normal range (10-20K goodevents)

Leakage current 3.6 uA

potentiometer = 20.28 mm

 

20/2/22

Leakage current ~3.675 uA. Looks stable now motors can not move (attachment 1)

potentiometer = 20.28 mm

Temperatures OK

System wide checks OK - white rabbit fails all

Statistic within normal range (see attachment 2 - ADC data items) Counter for aida 1 and aida 2 much higher due to noise bursts (elog 212)

 

XY total plot (attachment 3)

Low energy Ex histogram (attachment 4)

Low energy Ey histogram (attachment 5)

Tape Server data written (attachment 6)

 

Run end 20/2/22 15:08

Attachment 1: 2022-02-20_14-16-16-leakage-current.png
2022-02-20_14-16-16-leakage-current.png
Attachment 2: 2022-02-20_14-18-07-statistic-ADCdata.png
2022-02-20_14-18-07-statistic-ADCdata.png
Attachment 3: 2022-02-20_14-20-43-xyTotal.png
2022-02-20_14-20-43-xyTotal.png
Attachment 4: 2022-02-20_14-24-19-LowEnergy-ExTotal.png
2022-02-20_14-24-19-LowEnergy-ExTotal.png
Attachment 5: 2022-02-20_14-28-02-LowEnergy-EyTotal.png
2022-02-20_14-28-02-LowEnergy-EyTotal.png
Attachment 6: 2022-02-20_14-25-45-Tape-server-data-written.png
2022-02-20_14-25-45-Tape-server-data-written.png
  212   Sat Feb 19 14:51:58 2022 JM, CBBurst high energy noise

Noticed bursts of high energy noise on aida01 and aida02 during run 47 and 48.

Good events rate jumps from 10-20k range to 250k. ADC data items rate jumps from 0-1 to 2k. Data rate being written increases to ~2500 kb/s from ~20 kb/s

Effect appears short lived ~30s at a time. On 18/2/22 the asic was check loaded which appeared to remove the increased rate but due to the time taken to asic check the burst had already finished.

Asic 2 on aida01 and asic 1 on aida02 are affected. See attached plots.

Fast comparator threshold HEC currently set to 0x2 for all

Zoomed in region of aida 1 asic 2 and the same region for asic 1 to see the difference are attached.

 

Attachment 1: 2022-02-19_15-50-50-aida1-4-stat-logscale.png
2022-02-19_15-50-50-aida1-4-stat-logscale.png
Attachment 2: 2022-02-19_15-47-13-aida1-2*H.png
2022-02-19_15-47-13-aida1-2*H.png
Attachment 3: 2022-02-19_15-49-48-aida2-1*H.png
2022-02-19_15-49-48-aida2-1*H.png
Attachment 4: 2022-02-20_14-01-40-aida1-2*H.png
2022-02-20_14-01-40-aida1-2*H.png
Attachment 5: 2022-02-20_14-02-55-aida1-1*H.png
2022-02-20_14-02-55-aida1-1*H.png
  211   Fri Feb 18 20:31:33 2022 JM, CBAlpha Background run 48

Alpha background started with beam ON - run47. Run started 16:49 18/2/22   (beam subsequently found to be OFF)

Beam energy 4 keV, beam lifetime ~ 100 ms

Noticed aida01 and aida02 were showing increased good event rates to ~250,000, effect seen on spectrum browser and data writing rate increased to ~2500 kb/sec from ~20 kb/sec. ASIC check on the affected fees brought rates back to normal range 10-20k good events. Multiple instances occurred in a row on run47 so fees were power cycled. Run ended 17:21

Run 48 started after power cycle

Run start 17:42, beam OFF ~18:30-19:00 for access to the cave to aid allignment of the gas jet target.

Rates remain stable until ~20:00. Aida01 and 02 show increased rates, asic check -> back to normal range.

Beam ON 21:43

All system checks OK. All rates OK. Leakage current ~3.62 uA.

14:00 19/2/22

Beam OFF during 18/2/22 due to an interlock controlled by main control room unknown to us. Beam has been OFF. 

Leakage current plot attached. System checks OK, except white rabbit, all fail.

Motors were at 26mm potentiometer opposed to 20.2mm which was the set point (fully out 19mm). Motors dragged in as pneumatic was not fully out. Likely result of pneumatic out valve being closed. Pneumatic fully out, potentometer back to 20.2mm and leakage current drop from ~3.75 uA to 3.54uA.

Run ended 21:00

Attachment 1: 2022-02-19_14-45-25-leage-current.png
2022-02-19_14-45-25-leage-current.png
  210   Fri Feb 18 13:03:02 2022 RSS, ML, CBAlpha background run46

14:00

 

Check Leakage current: (see attachment 4)

Check NewMerger tab: (see attachment 2)

Check Fee temperatures: all green (see attachment 1)

Check statistics tab: ADC data items (see attachment 11)

                                 ADC coincidence-info #8 (see attachment 10)

                                 Good events (see attachment 9)

 Check Spectrum Browser tab: (see attachment 6)                 

Check the following plots:

                                         LowEnergyXYTotalDSSD0 (see attachment 7)

                                         LowEnergyExTotal (see attachment 8)

                                         LowEnergyEyTotal (see attachment 5)

                                        

                                       

Check system wide checks tab: White Rabbit error counter test result: Passed 0, Failed 5 (see attachment 3)

Data taking was stopped at 14:04.

Attachment 1: temp-2022-02-18_13-59-30.png
temp-2022-02-18_13-59-30.png
Attachment 2: merger-2022-02-18_13-58-41.png
merger-2022-02-18_13-58-41.png
Attachment 3: system-2022-02-18_13-59-57.png
system-2022-02-18_13-59-57.png
Attachment 4: leakage-2022-02-18_13-59-02.png
leakage-2022-02-18_13-59-02.png
Attachment 5: ey-total-2022-02-18_13-57-46.png
ey-total-2022-02-18_13-57-46.png
Attachment 6: spectrum-2022-02-18_14-02-02.png
spectrum-2022-02-18_14-02-02.png
Attachment 7: xy-total-2022-02-18_14-02-23.png
xy-total-2022-02-18_14-02-23.png
Attachment 8: ex-energy-2022-02-18_13-56-32.png
ex-energy-2022-02-18_13-56-32.png
Attachment 9: good-event-2022-02-18_14-00-53.png
good-event-2022-02-18_14-00-53.png
Attachment 10: correlation-2022-02-18_14-00-27.png
correlation-2022-02-18_14-00-27.png
Attachment 11: adc-data-item-2022-02-18_14-01-17.png
adc-data-item-2022-02-18_14-01-17.png
  209   Fri Feb 18 11:07:52 2022 RSS, ML, CBAlpha background run46

12:00

 

Check Leakage current: (see attachment 4)

Check NewMerger tab: (see attachment 2)

Check Fee temperatures: all green (see attachment 1)

Check statistics tab: ADC data items (see attachment 9)

                                 ADC coincidence-info #8 (see attachment 8)

                                 Good events (see attachment 7)

 Check Spectrum Browser tab: (see attachment 10)                 

Check the following plots:

                                         LowEnergyXYTotalDSSD0 (see attachment 11)

                                         LowEnergyExTotal (see attachment 5)

                                         LowEnergyEyTotal (see attachment 6)

                                        

                                       

Check system wide checks tab: White Rabbit error counter test result: Passed 0, Failed 5 (see attachment 3)

Attachment 1: temp-2022-02-18_12-01-21.png
temp-2022-02-18_12-01-21.png
Attachment 2: merger-2022-02-18_12-00-10.png
merger-2022-02-18_12-00-10.png
Attachment 3: system-2022-02-18_12-01-52.png
system-2022-02-18_12-01-52.png
Attachment 4: leakage-2022-02-18_12-00-43.png
leakage-2022-02-18_12-00-43.png
Attachment 5: energy-ex-2022-02-18_12-07-07.png
energy-ex-2022-02-18_12-07-07.png
Attachment 6: energy-ey-2022-02-18_12-05-29.png
energy-ey-2022-02-18_12-05-29.png
Attachment 7: good-event-2022-02-18_12-02-49.png
good-event-2022-02-18_12-02-49.png
Attachment 8: correlation-2022-02-18_12-03-19.png
correlation-2022-02-18_12-03-19.png
Attachment 9: adc-data-item2022-02-18_12-02-25.png
adc-data-item2022-02-18_12-02-25.png
Attachment 10: spectrum_browser-2022-02-18_12-03-55.png
spectrum_browser-2022-02-18_12-03-55.png
Attachment 11: energy-xy-total-2022-02-18_12-14-29.png
energy-xy-total-2022-02-18_12-14-29.png
  208   Fri Feb 18 08:58:08 2022 RSS, ML, CBAlpha background run46

10:00

 

Check Leakage current: (see attachment 2)

Check NewMerger tab: (see attachment 5)

Check Fee temperatures: all green (see attachment 1)

Check statistics tab: ADC data items (see attachment 3)

                                 ADC coincidence-info #8 (see attachment 6)

                                 Good events (see attachment 7)

 Check Spectrum Browser tab: (see attachment 9)                 

Check the following plots:

                                         LowEnergyXYTotalDSSD0 (see attachment 9)

                                         LowEnergyExTotal (see attachment 10)

                                         LowEnergyEyTotal (see attachment 11)

                                        

                                       

Check system wide checks tab: White Rabbit error counter test result: Passed 0, Failed 5 (see attachment 8)

Attachment 1: temp-2022-02-18_09-50-32.png
temp-2022-02-18_09-50-32.png
Attachment 2: leakage-2022-02-18_09-44-34.png
leakage-2022-02-18_09-44-34.png
Attachment 3: adc-data-2022-02-18_09-52-48.png
adc-data-2022-02-18_09-52-48.png
Attachment 4: energy_ex_2022-02-18_09-55-48.png
energy_ex_2022-02-18_09-55-48.png
Attachment 5: new-merger-2022-02-18_09-44-10.png
new-merger-2022-02-18_09-44-10.png
Attachment 6: correlation-2022-02-18_09-51-48.png
correlation-2022-02-18_09-51-48.png
Attachment 7: good-events-2022-02-18_09-52-17.png
good-events-2022-02-18_09-52-17.png
Attachment 8: system-wide-2022-02-18_09-51-08.png
system-wide-2022-02-18_09-51-08.png
Attachment 9: spectrum-browser-2022-02-18_09-53-52.png
spectrum-browser-2022-02-18_09-53-52.png
Attachment 10: energy-xy-total-2022-02-18_10-12-10.png
energy-xy-total-2022-02-18_10-12-10.png
Attachment 11: energy-ey-2022-02-18_09-58-53.png
energy-ey-2022-02-18_09-58-53.png
  207   Thu Feb 17 18:19:16 2022 JM, CB, SDAlpha Background run 46

Both GSI vacuum group and edinburgh ion gauges OFF

Fees power cycled. All system checks OK.

Writing to file, alpha background overnight.

Moved detector IN 2mm. Noise appears reduced with any distance moved in so overnight spectra to be taken while IN. Not moving further in as possible beam tomorrow.

22:44

Leakage current stable, slowly decreasing ~3.57 uA (attachment 1)

Statistics look OK

Temperatures OK

System wide check all pass - OK

Noise appears much reduced on spectrum Browser channels. (attachement 2). Compared to same plot on elog 197

XYtotal per pixel (attachment 3)

Ex histogram (attachment 4)

 

Attachment 1: 2022-02-17_22-41-45-leakageCurrent.png
2022-02-17_22-41-45-leakageCurrent.png
Attachment 2: 2022-02-17_22-51-07-aida1-3*L.png
2022-02-17_22-51-07-aida1-3*L.png
Attachment 3: 2022-02-17_22-54-06-XYTotal.png
2022-02-17_22-54-06-XYTotal.png
Attachment 4: 2022-02-17_22-56-38-ExHist.png
2022-02-17_22-56-38-ExHist.png
ELOG V3.1.4-unknown