Entry  Mon Feb 21 17:26:19 2022, JM, CB, SHB, OH (remotely), Beam ON run 53 9x
21/2/22 16:00

Call from main control room, beam is ON, probably has been for several hours judging by rate on xy total plot.

Changes made to online monitoring code by OH, include setting to only 1 DSSD, correct offsets from the pulser walkthrough, offline analysis capabilities
Entry  Mon Feb 21 12:10:47 2022, RSS, JG, Alpha background run50 220221_1506_aida03_1*W.png
Beam OFF. Run started 20/2/22 18:42

System checck OK, except white rabbit all fail

Temperatures OK
Entry  Mon Feb 21 10:59:48 2022, RSS, JG, Alpha background run50 
Beam OFF. Run started 20/2/22 18:42

System checck OK, except white rabbit all fail

Temperatures OK
Entry  Mon Feb 21 09:07:37 2022, RSS, JG, Alpha background run50 
Beam OFF. Run started 20/2/22 18:42

System checck OK, except white rabbit all fail

Temperatures OK
Entry  Mon Feb 21 08:05:45 2022, RSS, JG, Alpha background run50 
Beam OFF. Run started 20/2/22 18:42

System checck OK, except white rabbit all fail

Temperatures OK
Entry  Sun Feb 20 22:04:21 2022, JM, CB, Alpha Background run 50  
Beam OFF. Run started 20/2/22 18:42

Fast comparator threshold HEC set to 0xff for all fees and asics to combat high energy noise bursts.

Electron cooler scalar plugged back into aida03 ~3000 per sec.
Entry  Sat Feb 19 20:08:43 2022, JM, CB, Beam ON run 49 6x
Run started 19/2/22 21:05. Beam ON

Temperatures OK

System wide checks OK - white rabbit fails on all.
Entry  Sat Feb 19 14:51:58 2022, JM, CB, Burst high energy noise 2022-02-19_15-50-50-aida1-4-stat-logscale.png2022-02-19_15-47-13-aida1-2*H.png2022-02-19_15-49-48-aida2-1*H.png2022-02-20_14-01-40-aida1-2*H.png2022-02-20_14-02-55-aida1-1*H.png
Noticed bursts of high energy noise on aida01 and aida02 during run 47 and 48.

Good events rate jumps from 10-20k range to 250k. ADC data items rate jumps from 0-1 to 2k. Data rate being written increases to ~2500 kb/s from
~20 kb/s
Entry  Fri Feb 18 20:31:33 2022, JM, CB, Alpha Background run 48 2022-02-19_14-45-25-leage-current.png
Alpha background started with beam ON - run47. Run started 16:49 18/2/22   (beam subsequently found to be OFF)

Beam energy 4 keV, beam lifetime ~ 100 ms

Noticed aida01 and aida02 were showing increased good event rates to ~250,000, effect seen on spectrum browser and data writing rate increased
Entry  Fri Feb 18 13:03:02 2022, RSS, ML, CB, Alpha background run46 11x
14:00

 

Check Leakage current: (see attachment 4)
Entry  Fri Feb 18 11:07:52 2022, RSS, ML, CB, Alpha background run46 11x
12:00

 

Check Leakage current: (see attachment 4)
Entry  Fri Feb 18 08:58:08 2022, RSS, ML, CB, Alpha background run46 11x
10:00

 

Check Leakage current: (see attachment 2)
Entry  Thu Feb 17 18:19:16 2022, JM, CB, SD, Alpha Background run 46 2022-02-17_22-41-45-leakageCurrent.png2022-02-17_22-51-07-aida1-3*L.png2022-02-17_22-54-06-XYTotal.png2022-02-17_22-56-38-ExHist.png
Both GSI vacuum group and edinburgh ion gauges OFF

Fees power cycled. All system checks OK.

Writing to file, alpha background overnight.
Entry  Thu Feb 17 16:26:27 2022, JM, CB, SD, Gauges OFF, Pulser Movement tests 7x
Edinburgh group ion gauge turned OFF -> decrease in leakage current from 10.05 uA to 6.5 uA

GSI vacuum group ion gauge turned OFF -> decrease in leakage current from 6.5 uA to 3.63 uA

GSI large ion pump turned ON -> no effect on leakage current
Entry  Thu Feb 17 15:09:40 2022, JM,CB,SD, Alpha background run44 8x
16:09

 

Check Leakage current: (see attachment 1)
Entry  Thu Feb 17 13:12:19 2022, RSS, AG, Alpha background run43 11x
14:00

 

Check Leakage current: (see attachment 1)
Entry  Thu Feb 17 08:31:07 2022, RSS, AG, Alpha background run43 11x
09:15

Check Leakage current: (see attachment 2)

Check NewMerger tab: (see attachment 5)
Entry  Wed Feb 16 21:41:11 2022, JM, Run 43 Alpha Background 8x
22:41

Check Leakage current: (see attachment 1) = 10.01 uA and falling

Check NewMerger tab: (see attachment 2)
Entry  Wed Feb 16 21:27:31 2022, JM, Cryring signals, Pulser tests, Waveforms  11x
On 15/2/22 it was noted that the leakage current increases when the motors are moved IN. This is contary to tests conducted on 12/2/22 (elog 192) where
no increase was observed. 

16/2/22: Servo motor and pneumatic used to move in by different differences with leakage current observed to increase linearly with distance
Entry  Wed Feb 16 15:27:53 2022, EM, JM, Run 41 Pulser tests 11x
16:30

NOTE: Pulser is ON!

Check Leakage current: (see attachment 1)