Fri Jun 6 16:49:59 2025, CB, AY, ST, Beam overlap results for 200keV and 250keV
|
For 200keV the optimal horizontal position is -5mm.
For 250keV the optimal horizontal position is -2mm.
Both values are already given to the operators, so tomorrow we can just switch to 200keV and go on :) |
Thu Jun 5 16:54:18 2025, EW, ST, CB, Run 52 - 0.3 MeV/A 14x
|
Run 52 started at 17:53. Everything is running again. We started at 3E12 at/cm2
D+ beam deuterium target. D+ beam energy is now 0.3 MeV/u. (beam calc calculation is 0.3067 MeV/u).
All four detectors positioned fully out and stationary and also detector #4 is running again. |
Thu Jun 5 08:50:00 2025, JM, CF, CB, EW, Run 51 - background  
|
09:49
DSSD4 has been biased to 100V in steps of 5V from 60V. It was previously stable overnight at 60V - attachment 1
Will keep an eye on it but looks OK at the moment. Current bias and leakage current - attachment 2 |
Wed Jun 4 10:44:36 2025, EW, CB, JM, OF, JG, ST, Run 50 - 0.35 MeV/A 13x
|
11:30
Run 50 started.
D+ beam deuterium target. D+ beam energy is 0.35 MeV/u. (beam calc calculation is 0.3577 MeV/u) |
Wed Jun 4 00:10:39 2025, JM, Run 49 - beam only 6x
|
01:10
Gas target turned off via the shutter valve.
Run 49 started beam only background run. |
Tue Jun 3 14:54:29 2025, PMH, ST, Run 48 6x
|
Run 48 started. Everything is running again. We started at 3E13 at/cm2
D+ beam deuterium target. D+ beam energy is still 0.5 MeV/u. (beam calc calculation is 0.5143 MeV/u). See previous entry for beamcalc.
All four detectors positioned fully out and stationary, however we switched off detector #4. |
Tue Jun 3 11:16:07 2025, EW, EM, JM, Run 47, beam only background 
|
Run 47 started. Target cooling down after water cooler failure, beam only background
D+ beam deuterium target. D+ beam energy is 0.5 MeV/u. (beam calc calculation is 0.5143 MeV/u). See previous entry for beamcalc.
All four detectors positioned fully out and stationary. |
Mon Jun 2 20:03:43 2025, JG, AG, CB, EW, EM, Run 45/46, 0.5 MeV/A 13x
|
Run 45 started.
D+ beam deuterium target. D+ beam energy is 0.5 MeV/u. (beam calc calculation is 0.5143 MeV/u). See attachment for beamCalc
Target density is about 2e12 at/cm2 |
Mon Jun 2 17:48:07 2025, JG, AG, Run 44 scraper tests 
|
Same settings are Run 43 but with coasting beam and scrapers set to: 30 / - 30 mm.
all checks ok, but WR timestamp error, see attached |
Mon Jun 2 17:25:31 2025, JG, AG, Run 43 scraper tests
|
Same settings are Run 42 but bunched beam and scrapers set to: 30 / - 30 mm.
|
Mon Jun 2 16:35:35 2025, EW, AG, Run 42 and scraper tests 
|
17:00
Scraper tests conducted. We tried moving in the scrapers both at a fixed position throughout and also moving with the injection cycle.
We were unable to find a good position with the scrapers that did not produce significant scattering in the detectors. |
Mon Jun 2 09:30:38 2025, JM, EW, ST, Run 41 6x
|
Run 41 started.
D+ beam deuterium target. D+ beam energy is 0.75 MeV/u. (beam calc calculation is 0.7619 MeV/u). See previous entry for beamcalc.
Beam calc - Attachment 1 |
Sun Jun 1 15:33:50 2025, EW, JM, CB, Run 40 10x
|
16:30
Run 40 started.
D+ beam deuterium target. D+ beam energy is 0.75 MeV/u. (beam calc calculation is 0.7619 MeV/u) |
Sun Jun 1 07:46:34 2025, JM, EM, CB, Run 39 7x
|
08:45
Run 39 started.
D+ beam deuterium target. D+ beam energy is 1.0 MeV/u. (beam calc calculation is 1.0151 MeV/u) |
Sat May 31 10:46:42 2025, TD, Run 38 - remote monitoring 21x
|
11.40 DAQ continues
File G22-205/R38
|
Sat May 31 09:58:21 2025, JM, Run 38 10x
|
10:56
Run 38 started.
D+ beam deuterium target. D+ beam energy is 1.5 MeV/u. (beam calc calculation is 1.5160 MeV/u) |
Fri May 30 21:49:08 2025, JM, NP, CB, Run 37  
|
22:49
Run 37 started.
D+ beam deuterium target. D+ beam energy is 2 MeV/u. (beam calc calculation is 1.9211 MeV/u) |
Fri May 30 20:47:47 2025, JM, CB, NP, Run 36 
|
21:47
Run 36 started.
D+ beam deuterium target. D+ beam energy is 2 MeV/u. |
Fri May 30 20:06:48 2025, JM, CB, NP, Run35 8x
|
21:00
Run 35 started.
D+ beam deuterium target. D+ beam energy is 2 MeV/u. (beam calc calculation is 1.9211 MeV/u -> may be wrong cooler voltage, need to check |
Fri May 30 07:27:41 2025, CB LB JM NP EM, Waiting for deuterium 8x
|
08:27
No run going.
Temperatures OK - attach |