ID |
Date |
Author |
Subject |
658
|
Wed Jun 19 12:11:22 2024 |
CB, RSS | CARME status |
DSSD off
FEEs off
Motors out, pin inserted, compressed air closed, power removed from motors box.
Motors and temperature logs are in carme-gsi:logs/G22-200
Next experiment will install new setup attached to gas target. Some baking and vacuum operations required. Everything should stay off for safety until they are done. |
657
|
Wed Jun 19 12:08:34 2024 |
CB + various | Run 101-105 |
Run 101: no target. See ELOG entry by TD.
Run 102: ??
Run 103: ??
Run 104: After experiment time is over, Gleb tests beam lifetime at "high energies". Some data acquired for 30 minutes.
Run 105: Quick pulser walkthrough. People are working near CARME. Positive polarity 1000-9000 amplitude. |
656
|
Wed Jun 19 12:06:50 2024 |
CB, OF, SS | Run 98/99/100 - higher energy |
10:21 June 17
New energy: 1.125 MeV/u
Target in. Run 98 started.
Run 99 overlap check.
Run 100 back to acquisition as run 98. |
655
|
Wed Jun 19 12:04:02 2024 |
CB + OF, SS | Run 96/97 |
Run 96 - as run 89, while we wait for beam energy change at higher energies
Run stopped around 08:56 June 17
Run 97 - target out, beam optimisation for higher energies.
|
654
|
Wed Jun 19 12:01:29 2024 |
TD | 23:00-07:00 Wednesday 19 June |
23.18 DSSSD bias & leakage current OK - attachment 1
FEE64 temps OK - attachment 2
ADC data item stats attachment 3
aida01-aida04 c. 250k
per FEE64 1.8.W spectra - 20us FSR - attachments 4-5
large transients aida01-aida04
per FEE64 Rate spectra - attachment 6
Merger, TapeServer etc. - attachments 7-8
data file R101_15
DSSSD energy spectra (updating) - attachment 9
DSSSD bias & leakage current log - attachment 10
transients bottom & top left c. 02:00 18.6.24
cycle slow comparator 0x32 -> 0x64 -> Check ASIC Control -> 0x32
aida01 - aida04 rates return to normal
ADC data item stats - attachment 11
DSSSD energy spectra - attachment 12
23.40 cycle slow comparator 0x32 -> 0x64 -> Check ASIC Control -> 0x32
aida01 - aida04 rates return to normal
00.10 cycle slow comparator 0x32 -> 0x64 -> Check ASIC Control -> 0x32
aida01 - aida04 rates return to normal
01.43 ADC item stats OK - attachment 13
FEE64 temps OK - attachment 14
04.43 ADC data items stats
ADC data item stats - attachment 15
FEE64 temps OK - attachment 16
cycle slow comparator 0x32 -> 0x64 -> Check ASIC Control -> 0x32
aida01 - aida04 rates return to normal
ADC data item stats - attachment 17
per FEE64 Rate spectra - attachment 18
Merger, TapeServer etc. - attachment 19
data file R101_51
07.00 FEE64 temps OK - attachment 21
ADC data items OK - attachment 20
Merger, Tape Server OK - attachment 22
DSSSD bias & leakage current - attachment 23
DAQ stop, close data file
DSSSD bias OFF
FEE64 power OFF
Gzip'ing all uncompressed data files |
653
|
Wed Jun 19 12:00:56 2024 |
CB | Run 93/94/95 - background |
04:00 17 June
Moved the detectors back to the usual configuration (as per run 89).
Moved target away - background run.
Some issues with run numbers - see attached run name R93, but run 94 is written. See attached. 93 and 95 contain data. 94 does *not* exist.
No obvious differences wrt. target run, except Rutherford. |
652
|
Wed Jun 19 11:54:26 2024 |
CB | Run 91/92 - moving detectors |
~ 2:00 17 June
Run 91
Attempted to move the detectors closer to the beam, and move them in sync with the injection.
Found best position was
Right arm: s by 5 mm, r p in (not moving). No benefits from moving. 10 mm + r p in on sync results in beam clipping during injection. 69.55 mm not moving.
Left arm: s by 5 mm, l p in (in sync with motion). Due to the short beam preparation time, only the trigger out was used as per screenshots below. 23.58 -- 67.90 moving.
Saw spike on leakage current for both detectors on the right arm. Unsure if this because they are being moved, or because they were hit with beam. Leakage current recovered.
Run 92 - acquired data as above.
Rutherford locus more clear on left arm detectors. No clear sign of nuclear reactions signals. |
651
|
Mon Jun 17 23:10:08 2024 |
CB | Run 90 |
00:10
As run 89, detectors moved fully out.
01:20
TL detector noisy. Shook it. Fixed it.
Temps OK. Noise spike reported in Run 89 still there.
Target 6E11. Beam stable.
02:00
TL detector noisy. Shook it. Fixed it.
ELOG STOPPED WORKING
|
650
|
Mon Jun 17 16:26:00 2024 |
JM, RSS, CB | Run 89 |
17:20
(Run 87 Junk and Run 88 does not exist)
Beam charge state set to 5+. Energy is ~1.06 MeV/u
Cooler voltage setpoint 590.3 V.
FC20 read value 589.07 V.
Right arm at 64.60 mm
Left arm IN at 36.54 mm
FakeMotion script running
horizontal beam position 3.5 mm (new overlap position with new beam)
vertical beam position 0.0 mm
Beam intensity 7.0e+6 particles.
Target density ~5e11 at/cm2
Beam is stored in the ring for ~20 seconds. From beam overlap tests ~ 75% of the beam is destroyed in this time.
Beam halo appears slightly reduced. This may be due to reduced intensity and reduced injection rate (20 s vs 5s previously)
18:00
FEE64 temperatures OK
ADC data item stats OK
per FEE64 Rate spectra OK
Beam intensity 1.17e+7 particles
Target density ~5.25E11 atoms/cm2
20:28
FEE64 temperatures OK
ADC data item stats OK
per FEE64 Rate spectra OK
Beam intensity 1.08e+7 particles
Target density ~3.84E11 atoms/cm2
23:58
Temps OK. Stats OK. Merger OK. Write to disk OK.
Waveforms attached.
Beam keeps going away due to "solenoid" issues.
On-line analysis screenshots attached.
Without beam, we see a clear noise spike in all detectors every 50-200 seconds randomly. This is *not* correlated with beam injection or dump.
Checkloaded - no effect. Beam back - no changes. |
649
|
Mon Jun 17 06:26:45 2024 |
JM, OF, AK, CB | Change to 5+ beam |
07:00
We are changing to 5+ beam so that we can access higher energies and possibly observe a higher lying, wider resonance.
Beam energy change to 1.06 MeV/u.
Detectors out
Target nozzle out
Pressure in E1 had reached 2e-1 mbar and turbo was spinning down to 810 Hz. Pressure reduced and E1 has reduced to 8.2e-2 mbar. We may require a pressure increase when we want the target back?
Run changed and out into no storage mode so we do not write rubbish to disk.
11:34
Beam tuning in the ring in progress
Merger OK. Not writing to disk.
Temps OK. Rates OK.
Leakage current OK.
Motors out. Target out.
13:31
Checks OK. Beam tuning near completion.
Some data acquired during beam tuning attached. |
648
|
Mon Jun 17 05:47:35 2024 |
JM | Run 86 |
06:50
No sign of the resonance during night shift. New run started but when operators are avaiable we will likely move to higher energies to try and observe the (p,a) reaction.
Cooler voltage setpoint 247.8 V.
FC20 read value 247.25 V.
Right arm at 64.60 mm
Left arm IN at 36.54 mm
FakeMotion script running
horizontal beam position 1.0 mm
vertical beam position -5mm
Beam intensity 7.0e+7 particles.
Target density ~5e11 at/cm2 |
647
|
Mon Jun 17 04:01:16 2024 |
JM | Run 85 |
05:00
Cooler voltage setpoint 247.45 V.
FC20 read value 246.9 V.
Right arm at 64.60 mm
Left arm IN at 36.54 mm
FakeMotion script running
horizontal beam position 1.0 mm
vertical beam position -5mm
Beam intensity 7.0e+7 particles.
Target density ~5e11 at/cm2
Target temperature is 38.6 K. Values of E1 is 819 Hz, 2.7A, 1.85e-1 mbar
All checks OK |
646
|
Mon Jun 17 02:05:37 2024 |
JM | Run 84 |
03:00
Cooler voltage setpoint 247.7 V.
FC20 read value 247.15 V.
Right arm at 64.60 mm
Left arm IN at 36.54 mm
FakeMotion script running
horizontal beam position 1.0 mm
vertical beam position -5mm
Beam intensity 7.0e+7 particles.
Target density ~5e11 at/cm2
Target temperature is 38.6 K. Values of E1 is 820 Hz, 2.7A, 1.8e-1 mbar
All checks OK
03:34
Noise increase in top left dssd. Servo motor moved to resolve issue. |
645
|
Mon Jun 17 00:05:13 2024 |
JM | Run 83 |
01:00
Cooler voltage setpoint 247.6 V.
FC20 read value 247.05 V.
Right arm at 64.60 mm
Left arm IN at 36.54 mm
FakeMotion script running
horizontal beam position 1.0 mm
vertical beam position -5mm
Beam intensity 7.0e+7 particles.
Target density ~5e11 at/cm2
Target temperature is 38.6 K. Values of E1 is 820 Hz, 2.7A, 1.7e-1 mbar
All checks OK
02:50
Noise increase on dssd top left. Moved servo motor to resolve issue. |
644
|
Sun Jun 16 22:49:22 2024 |
JM | Run 82 |
23:38
Cooler voltage setpoint 247.5 V.
FC20 read value 246.95 V.
Right arm at 64.60 mm
Left arm IN at 36.54 mm
FakeMotion script running
horizontal beam position 1.0 mm
vertical beam position -5mm
Beam intensity 7.0e+7 particles.
Target density ~5e11 at/cm2
Target temperature is 38.6 K. Values of E1 is 820 Hz, 2.7A, 1.7e-1 mbar
All checks OK |
643
|
Sun Jun 16 22:40:11 2024 |
JM | Target overlap test - R81 |
23:10
Beam set to bunched mode to observe beam lifetime.
Electron cooler voltage setpoint kept at 246.8 V. Note this is 0.5 V lower than the previous test where the setpoint was 247.3 V
This corresponds to ~13.5 keV in the beam energy.
Attachment 1 shows target scan. Maximum still observed at a horizontal beam position of 1.0 mm.
Moving 0.5 V up or down does not impact the orbit enough to shift the beam position off the target.
Beam lifetime off target seems larger than previous, perhaps better vacuum conditions?
Back to coasting beam |
642
|
Sun Jun 16 19:01:30 2024 |
ML, EM | Run 80 |
20:00
Ecooler setpoint 246.8
Readout 246.25
Collector current 4.3
Target density ~5.3E11
Beam intensity 7E7 ions |
641
|
Sun Jun 16 13:51:11 2024 |
CB EM ML | Run 79 |
14:51
Ecooler setpoint 246.9
Readout 246.35
Collector current 4.3
Target density 4.6E11
Beam intensity 8E7 ions
Shook left arm to fix it.
15:32
Right half on BL detector was not counting. Checkloaded. Fixed.
17:20
Moved left arm out/in to fix it.
Reduced temperature to 38.5 K in steps as the target density was declining.
E1: pressure: 1.57E-1 mbar, turbo frequency: 819 Hz
Target density: 1.5E11 atoms/cm2; Ion beam intensity: 6E7 particles (went down slightly, have not been able to get everything back)
DSSSD bias & leakage current OK
FEE64 temperatures OK
ADC data item stats OK
per FEE64 Rate spectra OK
19:50
E1: pressure: 1.61E-1 mbar, turbo frequency: 819 Hz
Target density: 1.5E11 atoms/cm2; Ion beam intensity: 7E7 particles (recovered slightly)
DSSSD bias & leakage current OK
FEE64 temperatures OK
ADC data item stats OK
per FEE64 Rate spectra OK
|
640
|
Sun Jun 16 13:29:05 2024 |
RSS CB | Run 78 |
Target clogged? |
639
|
Sun Jun 16 06:02:31 2024 |
RSS | Run 77 |
Run 77 started at 06:48
Cooler voltage setpoint 247.0 V.
07:05
DSSSD bias & leakage current OK - attachments 1 & 2
FEE64 temperatures OK - attachment 3
ADC data item stats OK - attachment 4
per FEE64 Rate spectra OK - attachment 5
Beam intensity 8.45e+7 particles
Target density ~5.34E11 atoms/cm2
09:02
DSSSD bias & leakage current OK - attachments 6 & 7
FEE64 temperatures OK - attachment 8
ADC data item stats OK - attachment 9
per FEE64 Rate spectra OK - attachment 10
Beam intensity 7.85e+7 particles
Target density ~5.29E11 atoms/cm2
11:00
DSSSD bias & leakage current OK - attachments 11 & 12
FEE64 temperatures OK - attachment 13
ADC data item stats OK - attachment 14
per FEE64 Rate spectra OK - attachment 15
Beam intensity 8.5e+7 particles
Target density ~6.1E11 atoms/cm2
13:00
DSSSD bias & leakage current OK - attachments 16 & 17
FEE64 temperatures OK - attachment 18
ADC data item stats OK - attachment 19
per FEE64 Rate spectra OK - attachment 20
Beam intensity 8.2e+7 particles
Target density ~6.1E11 atoms/cm2 |