AIDA GELINA BRIKEN nToF CRIB ISOLDE CIRCE nTOFCapture DESPEC DTAS EDI_PSA 179Ta CARME StellarModelling DCF K40
  CARME, Page 5 of 38  ELOG logo
ID Date Authordown Subject
  505   Sat Feb 10 17:05:13 2024 TDRun 15 - background
17.55 DAQ continues G22-86/R15_11
      alpha background

      DSSSD bias OK - attachment 1
       ambient temperature 17.0 deg C

      FEE64 temperatures OK - attachment 2

      WR timestamps OK - attachment 3

      ADC data item stats - attachment 4
       rates dominated by 'hot' channels aida01 ( 85k ) and aida15 ( 11k ) - all other FEE64s c. 0Hz
       stats zero'd 17.57

      per FEE64 Rate & Stat spectra - attachments 5-6
       Stat spectra not zero'd recently - evidence of scattering ( rates varies with strip # )?

      aida01 ( p+n ) and aida03 ( n+n ) ASIC settings - attachments 7-8
       slow comparator 0x64

      Merger and Merger stats OK - attachments 9-10

      DSSSD leakage current = attachment 11
       shows data for 28-30.1.24 ?

      online sort per DSSSD x-y hit patterns - attachment 12

      ML vacuum pressure & cave temperature - attachments 13-14

23.01 DAQ continues G22-86/R15_17
      alpha background

      DSSSD bias OK - attachment 15
       ambient temperature 17.0 deg C

      FEE64 temperatures OK - attachment 16

      ADC data item stats - attachment 17
       rates dominated by 'hot' channels aida01 ( 72k ) and aida15 ( 11k ) - all other FEE64s c. 0Hz

      TapeServer - attachment 18

      DSSSD leakage current = attachment 19
       DSSSD #2 transient c. few hundred nA

      online sort per DSSSD x-y hit patterns - attachment 20
  506   Sun Feb 11 07:03:34 2024 TDSunday 11 February
02.02 DAQ continues G22-86/R15_21
      alpha background

      DSSSD leakage current = attachment 1
       DSSSD #2 transient c. few hundred nA continue

      FEE64 temperatures OK - attachment 2

      ADC data item stats - attachment 3
       rates dominated by 'hot' channels aida01 ( 70k ) and aida15 ( 11k ) - all other FEE64s c. 0Hz

      per FEE64 Rate and Stat spectra - attachments 4-5

02.07 All stats zero'd 


05.52 DAQ continues G22-86/R15_28
      alpha background

      FEE64 temperatures OK - attachment 6

      ADC data item stats - attachment 7
       rates dominated by 'hot' channels aida01 ( 72k ), aida15 ( 11k ), aida12 ( 3k ) and aida05 ( 600 )
       all other FEE64s c. 0Hz

      per FEE64 Stat spectra - attachment 8
       aida12 asic #2 HEC channels high rate

      Merger and TapeServer - attachments 9-10

      DSSSD leakage current = attachment 11
       DSSSD #2 transient c. few hundred nA continue

      online per DSSSD 2D x-y spectra - attachnent 12

05.56 All histograms & stats zero'd
      2x Check ASIC load

      ADC data item stats - attachment 7
       rates dominated by 'hot' channels aida01 ( 72k ), aida15 ( 11k )
       all other FEE64s c. 0Hz

10:28 DAQ continues G22-88/R15

      FEE temperatures OK

      ADC data items stats dominated by aida01 (86k) and aida15 (9k) rest of stats approx OHz. 
      Rates dominated by 2 hot channels per FEE 
      Leakage current plot (attachment 15)
      System wide checks OK
      Merger OK (500,000 items per sec), Tape server OK (710 kb/sec being written)
      DSSD XY plot (attachment 16) - some noise coming through in certain strips on DSSD 3
      DSSD Ey energy histograms (attachment 17)
      DSSD Ey vs Ex plots (attachment 18)     -  statistics for DSSD0,1,3 are consistent (DSSD 2 stats appear higher - unknown reason as yet)

11:10 Leakage current for DSSD1 (I2 on leakage current plot) remained 'turbulent'. We dropped the voltage from 150V to 100V. Leakage current dropped from ~4.5uA to ~4.2 uA. We will see if it remains more stable. 
      Rates in DSSD1 increased during change in voltage so all histograms were zero'd and monitoring code reset. Transient also observed for I3 in the leake current plot (attachment 19)

12:10 No progress on the target so far ...
      Noticed in aida03 and aida04 several missing channels in the stats spectrum browser (attachment 20)
      ASIC check load several times on aida03 and aida04. All stats and histograms zero'd 

13.37 Target now available - will attempt beam + target
      New data file G22-88/R16

13.39 per FEE64 Stat spectra

13.43 All histograms and stats zero'd

      multiple channels missing aida03 and aida04 ( and possibly other FEE64s too )
  520   Fri Feb 16 22:03:27 2024 TDRun 35 - night shift
22.51 DAQ continues file G22-86/R35_36

      DSSSD bias OK - attachments 1-2

      FEE64 temperatures - attachments 3-4
      CRYRING hall ambient temperature 20
      FEE64 temps tracking ambient temperature - aida01, aida03, aida09 and aida15 - all ( just ) over 65 deg C

      All system wide checks OK

      WR timestamps OK - attachment 5

      ADC, DISC and PAUSE data item stats - attachments 6-8
       hot channels aida01 ( 91k ), aida04 ( 12k ), aida15 ( 11k ) 

      per FEE64 Rate spectra - attachments 9-10
       aida04 & aida13 only FEE64s with significant rates and systematic rate variation with channel #

      per FEE64 1.8.L, 1.8.H and 1.8.W 20us FSR spectra - attachments 11-16

      Merger, Merger stats and TapeServer OK - attachments 17-19

23.16 All histograms, stats and merger stats zero'd

      Online analysis spectra - attachments 21-26
       only the inner quadrants of the 4x DSSSDs are correctly mapped - attachment 21
       observe double peak structure in DSSSD0 rate spectra - radiation damage most forward lab angle strips? - attachment 24

23.23 restart online analysis - zero spectra

23.30 YR12DTIC 2.5e7/s
      YR09 vacuum 7e-11 - 1.2e-10 mbar
      density 4e11/cm2
      See attachments 27-34



01.30 DAQ continues file G22-86/R35_39

      FEE64 temperatures - attachments 35-36

      ADC data item stats - attachment 37

      DSSSD leakage currents - attachment 38

      YR12DTIC 2.5e7/s
      YR09 vacuum 7e-11 - 1.2e-10 mbar
      density 4.1e11/cm2


03.05 YR12DTIC 2.2e7/s
      YR09 vacuum 7e-11 - 1.2e-10 mbar
      density 3.5e11/cm2

      DAQ continues file G22-86/R35_42

      DSSSD leakage currents - attachment 39

      FEE64 temperatures - attachments 40-41

      ADC data item stats - attachment 42

05.05 DAQ continues file G22-86/R35_47

      YR12DTIC 2.5e7/s
      density 3.8e11/cm2

      DAQ continues file G22-86/R35_42

      DSSSD leakage currents - attachment 43

      FEE64 temperatures - attachments 44-45

      ADC data item stats - attachment 46

      per FEE64 Rate spectra - attachments 47-48
       aida12 asic #1 and # 2 HEC activity 
       and following Check ASIC load aida12

      ADC data item stats - attachment 49


Shift Summary

Beam, target density and vacuum appear to have been stable overnight

FEE64 temperatures continue to cycle

Evidence of some radiation damage DSSSDD 0 presumably for most forward lab angle strips?

aida12 asic #1 and #2 high rate HEC activity - fixed by ASIC check load
  526   Sun Feb 18 13:10:18 2024 TDSunday 18 February - DSSSD 0 aida01 and aida04 *.*.L spectra
DSSSD 0 aida01 1*L spectra, aida04 **L spectra

Double peak structure feature of aida04 ( n+n Ohmic side ) strips. Single ( albeit sometimes broad peak ) observed in aida01 ( p+n junction side ) strips.
Not currently observed by DSSSD 1-3. DSSSD 0 high energy peak rate far higher than DSSSD 1-3.

Data from last week did not display this double peak but DSSSDs and beam have been moved since.

Unclear whether this reflects radiation damage and/or wafer/active area edge effects on the n+n side.
Might also reflect beam characteristics throughout cycle.

Requires calibration and dE cut to investigate.

JM comment -> early time cut analysis indicates this is a beam effect. DSSD#0 has majority of halo on it so double peak is very pronounced. 
We observe double peak all DSSDs just to a much lower level. 
  528   Sun Feb 18 22:03:56 2024 TDRun 42 night shift
23.03 DAQ continues file G22-86/R42_21

      ML CRYRING ambient temperature and vacuum - attachments 1 & 2

      DSSSD bias & leakage current - attachments 3 & 24
       DSSSD #0 trending upwards , DSSSD #1-3 trending downwards with decreasing ambient temperature

      FEE64 temperatures OK - attachments 4-5

23.07 All system wide checks OK

      WR timestamps OK - attachment 6

      ADC, DISC, PAUSE and correlation stats OK - attachments 7-10

      per FEE64 Rate spectra - attachments 11-12
      per FEE64 Stat spectra - attachments 13-14

      per FEE64 1.8.L, 1.8.H and 1.8.W 20us FSR spectra - attachments 15-20

      Merger, Merger stats and TapeServer OK - attachments 21-23

      online analysis spectra - attachments 25-30

23.28 all histograms, stats, Merger stats zero'd
      online analysis restarted

23.35 target density 5.83e+11/cm2
      beam no change in last 3 hours ( cannot read scale with X2Go )
      see attachments 31-33


00.58 DAQ continues file G22-86/R42_24

      DSSSD bias & leakage current - attachments 34-35
       DSSSD #0 trending upwards , DSSSD #1-3 trending downwards with decreasing ambient temperature

      FEE64 temperatures OK - attachments 36-37

      ADC data item stats - attachment 38

      per FEE64 Rate spectra - attachments 39

      target density 5.75e+11/cm2
      beam no change in last 3 hours ( cannot read scale with X2Go )


03.14 DAQ continues file G22-86/R42_28

      DSSSD bias & leakage current - attachments 40-41
       DSSSD #0 trending upwards , DSSSD #1-3 trending downwards with decreasing ambient temperature

      FEE64 temperatures OK - attachments 42-43

      ADC data item stats - attachment 44

      per FEE64 Rate spectra - attachments 45

      target density 5.91e+11/cm2
      beam decreased in last 3 hours ( cannot read scale with X2Go )
      see attachments 46-47

03:30 beam recovered
      online analysis rates DSSSD#0 recovered to values observed at start of shift
  529   Mon Feb 19 05:10:48 2024 TDRun 42 night shift contd.
06.03 DAQ continues file G22-86/R42_32

      DSSSD bias & leakage current - attachments 1-2
       DSSSD #0 trending upwards , DSSSD #1-3 trending downwards with decreasing ambient temperature

      FEE64 temperatures OK - attachments 3-4

      ADC data item stats - attachment 5

      per FEE64 Rate spectra - attachments 6

      target density 5.27e+11/cm2
      beam stable for last 3 hours ( cannot read scale with X2Go )
  539   Wed Feb 21 07:38:32 2024 TDWedneday 21 February
10.54 23.2.24 Bias OFF
  542   Fri Apr 19 02:47:59 2024 TDFriday 19 April
03.45




10.01 




10.05 DSSSD bias OFF
      FEE64 power OFF
  543   Tue Apr 23 17:44:41 2024 TDTuesday 23 April
18.43 ASIC settings 2024Feb08-15.59.09

aida06 pulser peak width 66 ch FWHM
  544   Wed Apr 24 12:48:35 2024 TDWednesday 24 April
      Replace AIDA ASIC mezzanine of aida01

13.43 DSSSD bias & leakage current OK - attachment 1
      ambient temperature 16.5 deg C

      FEE64 temperatures OK - attachment 2

      All system wide checks OK 

      WR timestamps OK - attachment 3

      ADC data item stats OK - attachment 4

      per FEE64 Rate spectra - attachment 5
       c. 10 strips (of 1024) not producing data
       most missing strips are from aida05 - misaligned or damaged adaptor PCB?

      per p+n FEE64 1.8.L spectra - attachment 6
       aida01 pulser peak width 75 ch FWHM
       common x/y scale => peak height proxy for peak width

      per n+n FEE64 1.8.L spectra - attachment 7
       aida01 pulser peak width 70 ch FWHM

      per FEE64 1.8.W spectra - 20us FSR - attachments 8-11

Summary

All FEE64s appear to be working (except aida05 which has c. 8 missing channels) with pulser - which 
validates the FEE64, ASICs and adaptor PCB.

Electronic noise c. 50keV FWHM for aida01 & aida03 - other FEE64s better/worse.

Preamplifier noise appears to be similar for all FEE64s which may suggest an issue with the test signal chain

Note
1) e-target is starting up
2) have identified some instances of poor CARME cable management/routing see https://elog.ph.ed.ac.uk/CARME/545



EG&G Ortec 448 Pulser
Amplitude 50,000
Normalise 5.00
x5 attenuator IN
t_r 100ns
tau_d 50us
Polarity +
Frequency relay line (50Hz)

Cooknell SA1 Summing Amplifier
inverted output to test - daisy chain

Current ASIC settings saved to 2024Apr24-14.14.03


14.48 Pulser OFF
 
      All histograms & stats zero'd

      LEC slow comparator 0x64 -> 0xff
      HEC fast comparator 0x2 -> 0x5

      background alpha run to validate signal path from DSSSD to FEE64 adaptor PCB

22.18 Start Merger & TapeServer - attachments 12-14

      DSSSD bias & leakage current OK - attachment 21
      ambient temperature 16.0 deg C


      FEE64 temperatures OK - attachment 15

      WR timestamps OK - attachment 16

      ADC data item stats OK - attachment 17

      per FEE64 Rate spectra - attachment 18

      per p+n FEE64 1.8.L spectra - attachments 19-20
  545   Wed Apr 24 13:18:09 2024 TDExamples of poor CARME cable management/routing
Have observed some instances of poor CARME cable management/routing
Attachment 1 - SAES D-2000 ion pump HV cable (netal braid) transiting FEE64 cabling
Attachment 2 - CARME motor controller cable (grey plastic) transiting FEE64 cabling

General check and tidying up required.
  546   Thu Apr 25 02:31:25 2024 TDThursday 25 April
03.27 DAQ continues - file APR24/R1_7

      DSSSD bias & leakage current OK - attachment 1
      ambient temperature 16.1 deg C

      FEE64 temperatures OK - attachment 2

      ADC data item stats OK - attachment 3

      per n+n FEE64 1.8.L spectra - attachment 4

      per FEE64 Stat spectra - attachment 5

      Merger, TapeServer etc - attachments 6-8


10.19 DAQ continues - file APR24/R1_8

      DSSSD bias & leakage current OK - attachment 9
      ambient temperature 16.2 deg C

      FEE64 temperatures OK - attachment 10

      ADC data item stats OK - attachment 11

      per FEE64 Stat spectra - attachment 12

      Merger, TapeServer etc - attachments 13-15

      NetVar merge variables - attachment 16


14.44 DAQ continues - file APR24/R1_10

      DSSSD bias & leakage current OK - attachment 17
      ambient temperature 16.5 deg C

      FEE64 temperatures OK - attachment 18

      ADC data item stats OK - attachment 19

      per FEE64 Stat spectra - attachment 20
       some HEC data has appeared

      Merger, TapeServer etc - attachments 21-23

19.12 DAQ continues - file APR24/R1_11

      DSSSD bias & leakage current OK - attachment 24
      ambient temperature 16.5 deg C

      FEE64 temperatures OK - attachment 25

      ADC data item stats OK - attachment 26

      per FEE64 Stat spectra - attachment 27

      per FEE64 1.8.L spectra - attachments 28-29

      Merger, TapeServer etc - attachments 30-32

23.14 DAQ continues - file APR24/R1_12

      DSSSD bias & leakage current OK - attachment 33
      ambient temperature 16.1 deg C

      FEE64 temperatures OK - attachment 34

      ADC data item stats OK - attachment 35

      per FEE64 Stat spectra - attachment 36

      Merger, TapeServer etc - attachments 37-39
  547   Fri Apr 26 07:05:01 2024 TDFriday 26 April
08.02 DAQ continues data file R1_14

      DSSSD bias & leakage current OK - attachment 1

      FEE64 temps OK - attachment 2

      ADC data item stats OK - attachment 3

      per FEE64 Rate spectra - attachment 4 

      Merger, TapeServer etc - attachments 5-7

10.40 Close file R1 and open file R2

      Switch on pulser (relay line 50Hz)

      per FEE64 Rate spectra - attachment 8

      Check ASIC load x2 for aida09, aida10, aida12, aida15  aida16

      per FEE64 Rate spectra - attachment 12
       status quo ante

      Pulser walkthrough 

      Pulser settings per https://elog.ph.ed.ac.uk/CARME/544
      Amplituides 70,000-10,000 @ 10,000 step

      per FEE64 1.8.L spectra - attachments 9-10
 
      per FEE64 Rate spectra - attachment 11

11.05 Pulser OFF
      Close file R2, open file R3

      zero all histograms  stats

      background alpha run continues


20.33 DAQ continues data file R3_8

      DSSSD bias & leakage current OK - attachment 13

      FEE64 temps OK - attachment 14

      ADC data item stats OK - attachment 15

      per FEE64 Rate spectra - attachment 16

      Merger, TapeServer etc - attachments 1-19


      CAEN data log stopped 00:21 Friday 26 April 

pi@nnrpi1:~/Programs/caenlogger $ caenlogger --config caenlogger_config_gsi.toml
2024-04-25 15:25:16.194 | INFO     | caenlogger.__main__:main:117 - Config file provided.
Traceback (most recent call last):
  File "/home/pi/.local/bin/caenlogger", line 10, in <module>
    sys.exit(main())
  File "/home/pi/.local/lib/python3.7/site-packages/caenlogger/__main__.py", line 135, in main
    curses.wrapper(process, config_dic)
  File "/usr/lib/python3.7/curses/__init__.py", line 94, in wrapper
    return func(stdscr, *args, **kwds)
  File "/home/pi/.local/lib/python3.7/site-packages/caenlogger/__main__.py", line 57, in process
    Vmon = [ f for f in HV[5].strip().split("  ") if f ]
IndexError: list index out of range

     Old log gzip'd and moved to directory ~/logs

[npg@carme-gsi ~]$ mv caen_current.dat.gz logs/0031260424-caen_current.dat.gz

20.45 Restarted logger program
  548   Fri Apr 26 23:41:16 2024 TDSaturday 27 April
00.34 DAQ continues data file R3_9

      DSSSD bias & leakage current OK - attachment 1

      FEE64 temps OK - attachment 2

      ADC data item stats OK - attachment 3

      per FEE64 Rate spectra - attachment 4

      Merger, TapeServer etc - attachments 5-7

06.41 DAQ continues data file R3_10

      DSSSD bias & leakage current OK - attachment 8

      FEE64 temps OK - attachment 9

      ADC data item stats OK - attachment 10

      per FEE64 Rate spectra - attachment 11

      Merger, TapeServer etc - attachments 12-14


10.56 DAQ continues data file R3_11

      DSSSD bias & leakage current OK - attachment 15

      FEE64 temps OK - attachment 16

      ADC data item stats OK - attachment 17

      per FEE64 Rate spectra - attachment 18

      Merger, TapeServer etc - attachments 19-21

14.33 DAQ continues data file R3_12

      DSSSD bias & leakage current OK - attachment 22

      FEE64 temps OK - attachment 23

      ADC data item stats OK - attachment 24

      per FEE64 Rate spectra - attachment 25

      Merger, TapeServer etc - attachments 26-28

18.31 DAQ continues data file R3_13

      DSSSD bias & leakage current OK - attachment 29

      FEE64 temps OK - attachment 30

      ADC data item stats OK - attachment 31

      per FEE64 Rate spectra - attachment 32

      per FEE64 1.8.L spectra - attachments 33-34

      Merger, TapeServer etc - attachments 35-37
  549   Sat Apr 27 23:16:02 2024 TDSunday 28 April
00.12 DAQ continues data file R3_15

      DSSSD bias & leakage current OK - attachment 1

      FEE64 temps OK - attachment 2

      ADC data item stats OK - attachment 3

      per FEE64 Rate spectra - attachment 4

      Merger, TapeServer etc - attachments 5-7


05.32 DAQ continues data file R3_16

      DSSSD bias & leakage current OK - attachment 8

      FEE64 temps OK - attachment 9

      ADC data item stats OK - attachment 10

      per FEE64 Rate spectra - attachment 11

      Merger, TapeServer etc - attachments 12-14

11.27 DAQ continues data file R3_17

      DSSSD bias & leakage current OK - attachment 15

      FEE64 temps OK - attachment 16

      ADC data item stats OK - attachment 17

      per FEE64 Rate spectra - attachment 21

      Merger, TapeServer etc - attachments 18-20

11.33 aida16 asic #2 2x Check ASIC control
      aida16 asic #4 2x Check ASIC control


18.53 DAQ continues data file R3_19

      DSSSD bias & leakage current OK - attachment 22

      FEE64 temps OK - attachment 23

      ADC data item stats OK - attachment 24

      per FEE64 Rate spectra - attachment 25

      Merger, TapeServer etc - attachments 26-28

      per FEE64 1.8.H - attachments 29-30

      per FEE64 1.8.L - attachments 31-32

      per FEE64 1.8.W - 20us FSR - attachments 33-36

19.10 CRYRING ambient temperature per https://web-docs.gsi.de/~lestinsk/tempplot.php - attachment 37
  550   Sun Apr 28 23:12:11 2024 TDMonday 28 April
00.09 DAQ continues data file R3_21

      DSSSD bias & leakage current OK - attachment 1

      FEE64 temps OK - attachment 2

      ADC data item stats OK - attachment 3

      per FEE64 Rate spectra - attachment 4

      Merger, TapeServer etc - attachments 5-7

04.50 DAQ continues data file R3_22

      DSSSD bias & leakage current OK - attachment 8

      FEE64 temps OK - attachment 9

      ADC data item stats OK - attachment 10

      per FEE64 Rate spectra - attachment 11

      Merger, TapeServer etc - attachments 12-14


09.41 DAQ continues data file R3_23

      DSSSD bias & leakage current OK - attachment 15

      FEE64 temps OK - attachment 16

      ADC data item stats OK - attachment 17

      per FEE64 Rate spectra - attachment 18

      Merger, TapeServer etc - attachments 19-21


09.43 DAQ stopped
      DSSSD bias OFF
      FEE64 power OFF
  559   Wed May 29 17:42:06 2024 TDOffline analysis APR24/R2 (pulser walkthrough)
ADC offsets using pulser walkthrough data from data file APR24/R2

ch = channel + ( module * 64 ) + ( range * 2048 )

adc_data( ch ) = INT( RSHIFT( ABS( adc_data( ch ) - 32768 ), 3 ) - offset( ch ) + 0.5 )




per FEE64 ADC spectra - attachments 1-16

Note common x & y-scales - peak height proxy for peak width

aida01 1.8.L (s7) pulser peak width 9 ch FWHM (~50keV FWHM)




ADC offset analysis

/home/td/Calibration/offsets /home/td/CARME/R2 50 2048 20 5

First pass sort variables NAMELIST I/O format ( ADC offsets, FEE64 configuration, LEC & HEC equal energy cuts ) - attachment 17
  570   Sat Jun 1 13:33:50 2024 TDOffline analysis APR24/R3 (alpha background)
Offline analysis data file APR24/R3 (alpha background)

Run started 11:04 26.4.24
Run ended   09:44 29.4.24

Sort program variables https://elog.ph.ed.ac.uk/CARME/240530_180659/variables.dat

ADC data corrected for ADC offset but not gain

per DSSSD m_p verus m_n - attachment 1

For spectra below events must satisfy condition 0 < m_p < 8 *and* 0 < m_n < 8

per DSSSD p+n junction strip versus n+n Ohmic strip - attachment 2
 note - x/y channel ordering to be checked

per DSSSD E_p versus E_n - attachment 3
 20keV/channel nominal

per DSSSD E_p versus E_n - attachment 4
 gated w(1) & w(2)
 20keV/channel nominal

per DSSSD projection of gated E_p versus E_n spectra - attachments 5-8
 20keV/channel nominal

2D spectra z contours/colour map - attachment 9
  571   Sat Jun 1 16:38:13 2024 TDOffline analysis G22-201/R17
Offline analysis data file G22-201/R17

Sort program variables https://elog.ph.ed.ac.uk/CARME/240530_180659/variables.dat

ADC data corrected for ADC offset but not gain

per DSSSD m_p verus m_n - attachment 1
 DSSSD #2 spectrum is normal, DSSSD #1 and #3-4 display large multiplicities in p and/or n strips which are, presumably, non-physical events at DSSSD edge

For spectra below events must satisfy condition 0 < m_p < 8 *and* 0 < m_n < 8

per DSSSD p+n junction strip versus n+n Ohmic strip - attachment 2
 note - x/y channel ordering to be checked

per DSSSD E_p versus E_n - attachment 3
 20keV/channel nominal

per DSSSD E_p versus E_n - attachment 4
 gated w(1) & w(2)
 20keV/channel nominal

per DSSSD projection of gated E_p versus E_n spectra - attachments 5-8
 20keV/channel nominal
 log scale
  576   Sun Jun 2 14:30:16 2024 TDOffline analysis G22-201/R22_0 - R22_11
Offline analysis data file G22-201/R22_0 to R22_11

Sort program variables https://elog.ph.ed.ac.uk/CARME/240530_180659/variables.dat

ADC data corrected for ADC offset but not gain

per DSSSD m_p verus m_n - attachment 1

For spectra below events must satisfy condition 0 < m_p < 8 *and* 0 < m_n < 8

per DSSSD p+n junction strip versus n+n Ohmic strip - attachment 2
 note - x/y channel ordering to be checked

per DSSSD E_p versus E_n - attachment 3
 20keV/channel nominal

per DSSSD E_p versus E_n - attachment 4
 gated w(1) & w(2)
 20keV/channel nominal

per DSSSD projection of gated E_p versus E_n spectra - attachments 5-8
 20keV/channel nominal
ELOG V3.1.4-unknown