AIDA GELINA BRIKEN nToF CRIB ISOLDE CIRCE nTOFCapture DESPEC DTAS EDI_PSA 179Ta CARME StellarModelling DCF K40
  DESPEC  ELOG logo
Message ID: 177     Entry time: Sun Mar 7 07:23:26 2021
Author: CA, LS 
Subject: March 7th  
08:00 ASIC settings 2019Dec19-16.19.51
      DSSSD#1 slow comparator 0xa
      DSSSD#2 slow comparator 0xa
      DSSSD#3 slow comparator 0xa

      BNC PB-5 Pulser 
      Amplitude1.0V
      Attenuation x1
      Frequency 2Hz
      tau_d 1ms
      - polarity
      Delay 250ns, tail pulse


08:30 - all system wide checks ok

      - Temperatures ok - attachment 1

      - good event statistics ok - attachment 2

      - detector bias/leakage currents ok - attachment 3

      DAQ continues to run - R1_1148

      Merger ok - 4.6M data items/s

      TapeServer ok - 43MB/s

08:55 Giovanna Benzoni - confirms contribution of light ions - attachment 4 see AOQ plots

09:19 zeroed all histograms

      writing to file R1_1204

      FRS on file 72

      DESPEC to add AIDA XY hit patterns to online analysis histograms

09:35 beam stop

09:56 beam back 

      writing to file R1_1249

      rate spectra - attachment 5

09:30 AIDA DAQ crashed - lost connection to aida05

      power cycle and reset

09:40 AIDA ok now, writing to file R2

09:50 LS takes over

11.10 (German time)
      System wide checks produces some fails: 
      FEE64 module aida06 global clocks failed, 6 (screenshot6)
      This error is seen in RIKEN too, tried a RESYNC from master timestamp tab but error still there

      FEE64 module aida06 failed
      FEE64 module aida07 failed
      Calibration test result: Passed 10, Failed 2 (screenshot7)
      Tried a recalibration for the two FEEs in FADC align & control tab but error still there

      Rest of the checks pass
      Statistics (screenshot8)
      FEE temps okay (screenshot9)
      Leakage currents written to sheets (screenshot10)
      Merger ~4.5M data items/s
      TapeServer ~ 45MB/s

13.00 System wide checks produces same fails as last time: 
      FEE64 module aida06 global clocks failed, 6
      FEE64 module aida06 failed
      FEE64 module aida07 failed
      Calibration test result: Passed 10, Failed 2
      Rest of the checks are okay

      Statistics (screenshot11)
      Spectra rate (screenshot12)
      FEE temps okay (screenshot13)
      Leakage currents written to sheets (screenshot14)
      Merger ~4.5M data items/s
      TapeServer ~ 45MB/s
      There is 1.5TB left on current drive

14.00 beam stopped to look at bPlast, have use the time to change slow comparator threshold
      Slow comparators in FEE9-12 raised to 0xd
      

      

      
      
      



        
Attachment 1: Screenshot_from_2021-03-07_07-30-28.png  157 kB  | Hide | Hide all
Screenshot_from_2021-03-07_07-30-28.png
Attachment 2: Screenshot_from_2021-03-07_07-31-27.png  120 kB  | Hide | Hide all
Screenshot_from_2021-03-07_07-31-27.png
Attachment 3: Screenshot_from_2021-03-07_07-31-55.png  46 kB  | Hide | Hide all
Screenshot_from_2021-03-07_07-31-55.png
Attachment 4: Screenshot_from_2021-03-07_07-53-05.png  279 kB  | Hide | Hide all
Screenshot_from_2021-03-07_07-53-05.png
Attachment 5: Screenshot_from_2021-03-07_08-59-23.png  181 kB  Uploaded Sun Mar 7 09:00:20 2021  | Hide | Hide all
Screenshot_from_2021-03-07_08-59-23.png
Attachment 6: 1110_Systemchecks.PNG  132 kB  Uploaded Sun Mar 7 10:36:01 2021  | Hide | Hide all
1110_Systemchecks.PNG
Attachment 7: 1110_Systemchecks2.PNG  116 kB  Uploaded Sun Mar 7 10:36:06 2021  | Hide | Hide all
1110_Systemchecks2.PNG
Attachment 8: 1110_Statistics.PNG  122 kB  Uploaded Sun Mar 7 10:43:18 2021  | Hide | Hide all
1110_Statistics.PNG
Attachment 9: 1110_FEEtemps.PNG  158 kB  Uploaded Sun Mar 7 10:43:30 2021  | Hide | Hide all
1110_FEEtemps.PNG
Attachment 10: 1110_Leakagecurrents.PNG  31 kB  Uploaded Sun Mar 7 10:43:34 2021  | Hide | Hide all
1110_Leakagecurrents.PNG
Attachment 11: 1300_Statistics.PNG  123 kB  Uploaded Sun Mar 7 12:12:53 2021  | Hide | Hide all
1300_Statistics.PNG
Attachment 12: 1300_Spectrumrate.PNG  205 kB  Uploaded Sun Mar 7 12:13:00 2021  | Hide | Hide all
1300_Spectrumrate.PNG
Attachment 13: 1300_FEEtemps.PNG  158 kB  Uploaded Sun Mar 7 12:13:04 2021  | Hide | Hide all
1300_FEEtemps.PNG
Attachment 14: 1300_Leakagecurrents.PNG  31 kB  Uploaded Sun Mar 7 12:13:09 2021  | Hide | Hide all
1300_Leakagecurrents.PNG
ELOG V3.1.4-unknown