Took over the shift from Marc.
08:00 FULL CHECK
DSSSD bias & leakage current ok - attachment # 1-2
FEE64 temperatures ok - attachment # 3
ADC data item stats - attachment # 4
Merger ok - Attachement # 5
Tape service - attachement # 6
10:00 FULL CHECK
DSSSD bias & leakage current ok - attachment # 7-8
FEE64 temperatures ok - attachment # 9
ADC data item stats - attachment # 10
Merger ok - Attachement # 11
Tape service - attachement # 12
12:00 FULL CHECK
DSSSD bias & leakage current ok - attachment # 13-14
FEE64 temperatures ok - attachment # 15
ADC data item stats - attachment # 16
Merger ok - Attachement # 17
Tape service - attachement # 18
12.34 analysis data file S181/R7_610 - attachment 19
max deadtime 8.7% (aida08), all other FEE64s < 2.7%
LEC data rate 2.000M, HEC data rate 4.7k
12.52 per p+n FEE64 1.8.L spectra - attachment 20
aida09 pulser peak width 63 ch FWHM
per FEE64 1.8.H spectra - attachments 21-22
per FEE64 1.8.W spectra - 20us FSR - attachments 23-24
13.00 all histograms zero'd
14:00 FULL CHECK
DSSSD bias & leakage current ok - attachment # 19-20
FEE64 temperatures ok - attachment # 21
ADC data item stats - attachment # 22
Merger ok - Attachement # 23
Tape service - attachement # 24
13.01 Beam OFF for S4 access
ADC data item stats - attachment 25
per FEE64 Rate spectra - attachment 26
14.12 analysis data file R7_654 - attachment 27
max deadtime 3.9% (aida08), all other FEE64s < 3%
LEC data rate 1.817M, HEC data rate 2.5k
14.00 data file R7_649 - attachment 28
max deadtime 4.5% (aida08), all other FEE64s < 3%
LEC data rate 1.756M, HEC data rate 2.5k
16:00 FULL CHECK
DSSSD bias & leakage current ok - attachment # 25-26
FEE64 temperatures ok - attachment # 27
ADC data item stats - attachment # 28
Merger ok - Attachement # 29
Tape service - attachement # 30 |