AIDA GELINA BRIKEN nToF CRIB ISOLDE CIRCE nTOFCapture DESPEC DTAS EDI_PSA 179Ta CARME StellarModelling DCF K40
  EDI_PSA, Page 2 of 2  ELOG logo
Entry  Tue Jul 9 13:05:17 2019, CB, Jul 8 
Found VME crate yesterday reporting AC power failure. Workstation unresponsive.

Power cycled everything and restarted -> all OK.
Entry  Tue Jul 9 13:31:20 2019, CB, Tests with positive pulses 190709_PositivePulse.png190709_BaselineMean.png
According to Carl U. the DPP-PSA software is not meant to be used with negative pulses, and some of the
functions that are currently not working may be recovered fixing this issue.
Entry  Tue Jun 1 14:59:06 2021, CB, 2021/R3_0 Analysis - 3 lines 7x
Fit: 3 lines
Free parameters: 2x boundary points between lines
Algorithm: Nelder-Mead, 10 iterations. (Centroid defined incorrectly from entire simplex instead of best two
Entry  Tue Jun 1 15:19:40 2021, CB, 2021/R3_0 Analysis - 2 lines + power law 11x
Fit: line + power law + line
Free parameters: 2x boundary points between lines
Algorithm: Nelder-Mead, 10 iterations. (centroid correct)
Entry  Wed Jun 2 10:26:31 2021, CB, 2021/R3_0 Analysis - 2 lines + power law - 20 iterations H.pngt.pngComparison.png
Fit: line + power law + line
Free parameters: 2x boundary points between lines
Algorithm: Nelder-Mead, *20* iterations.
Entry  Mon Jun 7 17:41:55 2021, CB, Long background analysis 7x
Fit: line + power law + line
Free parameters: 2x boundary points between lines
Algorithm: Nelder-Mead, 20 iterations.
Entry  Tue Jun 8 11:04:36 2021, CB, R11 (long background) dead time Pulser.png
Pulser frequency: 2.165 Hz (462 ms)

Attach 1: Pulser events vs. total events

 
Entry  Fri Jun 11 10:56:45 2021, CB, R13 H.pngAlpha_candidate.png
Fit: line + power law + line
Free parameters: 2x boundary points between lines
Algorithm: Nelder-Mead, 20 iterations.
Entry  Tue Jun 15 13:15:48 2021, CB, R14 analysis H.pngt.pngElectron_t26.pngElectron_t153.png
Fit: line + power law + line
Free parameters: 2x boundary points between lines
Algorithm: Nelder-Mead, 20 iterations.
Entry  Wed Jun 23 08:23:07 2021, CB, R14 analysis 2 9x
Given very poor fit using line + power law + line, changes were made to the fitting algorithm.
- Starting paramters optimised for new typical wave shape
- Reverted to 3 lines, since signals are faster
ELOG V3.1.3-7933898