Entry  Wed Nov 8 23:46:32 2017, Daid, Charge State Distributions  charge-state-distribution-3.6.jpgcharge-state-distribution-4.0.jpgcharge-state-distribution-4.4.jpgcharge-state-distribution-4.7.jpgcharge-state-distribution-5.0.jpg
    Reply  Thu Nov 9 05:33:50 2017, TD, Charge State Distributions  
Message ID: 54     Entry time: Wed Nov 8 23:46:32 2017     Reply to this: 57
Author: Daid 
Subject: Charge State Distributions  
Faraday cup readout at the end of our chamber should change based on whether or not the target is in and also the 59Cu beam energy.

The effect could be as much as 10 to 20%.  At some point, we should check the Faraday cup reading with the CH2 target and with the empty target.