AIDA GELINA BRIKEN nToF CRIB ISOLDE CIRCE nTOFCapture DESPEC DTAS EDI_PSA 179Ta CARME StellarModelling DCF K40
  ISOLDE  ELOG logo
Message ID: 58     Entry time: Thu Nov 9 05:35:44 2017
Author: Daid. Mirco 
Subject: Run 56 
Header: 5.0 MeV/u CH2, Laser 2 is turned off on purpose to check background.
Ender: Could not see many real events beside pulser and current was very low
====================================================
Run number			: 56
Date				: 9 Nov 2017
Start time			: 06:34:45
Stop time			: 06:54:37
Trigger rate (MIDAS)	        : 2030
Blocks written		        : 2488
覧覧覧覧覧覧覧覧覧覧覧覧覧覧覧
Beam energy			: 5.0 MeV/u
Beam intensity		        : (cannot be measured)
Target				: #2 CH2_16 (450~480 ug/cm^2)
Ladder position		        : 127.95 mm
HI Degrader foil (um)		: 15 um Al
覧覧覧覧覧覧覧覧覧覧覧覧覧覧覧
del_E voltage (V)		: -32 V
del_E leakage (uA)		:  0.025 uA
E voltage (V)			: -350 V
E leakage (uA)		        :  1.735 uA
E_hi voltage (V)		: -14 V
E_hi leakage (uA)		:  0.825 uA
覧覧覧覧覧覧覧覧覧覧覧覧覧覧覧
PA power (upstream, positive)	:  1.53 A
PA power (upstream, negative)   :  -0.55 A
PA power (downstream, positive)	:  0.8 A
PA power (downstream, negative) :  -0.28 A
覧覧覧覧覧覧覧覧覧覧覧覧覧覧覧
Pressure (IMG1)		        :  7.4 x 10^-6 mbar
Pressure (old gauge)	        :  2.2 x 10^-5 mbar
Pressure (SEC)	           	:  3.9 x 10^-6 mbar
覧覧覧覧覧覧覧覧覧覧覧覧覧覧覧
Temp (Chiller)		        :  - 10.1 deg
Temp (chamber)		        :  + 5.5 deg
覧覧覧覧覧覧覧覧覧覧覧覧覧覧覧
comment: Why is the trigger rate nearly the same with the laser on and off ??!!
ELOG V3.1.4-unknown