Entry  Mon Oct 7 14:07:26 2024, AR, Zn update slides 04/10 update_zn68.pdf

Models Vs Resonance amp spectra 

Entry  Mon Sep 9 11:06:19 2024, AR, Zn update slides 06/08/2024 update_zn68.pdf
 
Entry  Fri Jun 7 15:58:24 2024, CLW, ISOFLEX Certificates for enriched Si samples Si30_isoflex.pdf231226-01_-_Shipping_Documents(1).pdf

Isoflex certificates for enriched silicon samples

Entry  Tue Apr 16 15:24:45 2024, AR, Zn68 Analysis: Au resonance SAMMY fits Au_4ev_yield_sammy_fit_det1.pdfAu_45-48ev_sammy_fit_det1.pdfAu_59-62ev_sammy_fit_det1.pdfAu_78ev_sammy_fit_det1.pdfAu_107ev_sammy_fit_det1.pdf
 
Entry  Thu Apr 4 09:50:36 2024, CLW, First Si analysis 2024 run 6x

Au and Si29 runs normalised by proton number show consistency (dedicated pulses, example detector 4). Plots for tof spectra zooming on one resonance and histogram of counts in this resonance divided by protons with statistical errors.

Plots were produced with the macros attached.

Entry  Tue Mar 26 11:04:29 2024, AR, Si-29 and Si-28 sample images and info 11x

Sample information Excel sheet attached below.

Images 1-6: Si-29 sample

Images 6-10: Si-28 sample

Image 11: screenshot from Excel sheet for Si-29

Image 12: screenshot from Excel sheet for Si-28

Image 13: screenshot from Excel sheet for Dummy

Both samples were only able to be weighed inside the capsule as they were very crumbly and unable to be weighed alone (see images). The capsule was weighed before the sample was put in it and thus the mass of Si can be found by subtracting the capsule mass from the measured mass.

Average mass Si-29: 0.8568g pm 0.0002

Average mass Si-28: 0.9551 pm 0.0002

Average mass Dummy: 0.0765 pm 0.0001

 

Entry  Mon Mar 25 09:07:53 2024, Nick, Proton Monitoring 

https://docs.google.com/spreadsheets/d/18lk27N6Pb2iT_xtDA-1T1c9vVubXTJ0OsaDjOxErP0I/edit?usp=sharing

Entry  Sat Mar 23 15:06:44 2024, Nick, Detector Setup - 28/29Si Campaign 2024 9x

Campaign started yesterday. C6D6s placed at 9 cm distance, angle 125 degrees w.r.t beamline.

Measured calibration sources: Cs137, Y88, AmBe, CmC. Measuring Si-nat over the weekend.

Detector          Voltage

    C6D6_D_1 1550          
    C6D6_E_2 1590          
    C6D6_H_3 1460          
    C6D6_L_4 1450

 

Entry  Fri Mar 1 14:35:04 2024, AR, Zn updated wartime v weighted plots 13x

Updated plots with new WFs. Rebinned by 10.

Entry  Tue Feb 27 11:37:39 2024, AR, Updated Au Deadtime Corrected Spectra & Weighted Spectra Plots  12x

Plots made with new weighting functions. All rebinned by 10.

Attatchments 1-4: Detector 1.

Attatchments 5-8: Detector 2.

Attatchments 9-12: Detector 3.

Entry  Fri Dec 1 15:34:01 2023, AR, Corrected BG Subtraction plots for Zn and Au 6x

Updated plots for Zn and Au

Entry  Thu Nov 30 14:43:28 2023, AR, Zn + Au Background subtraction: Plots 21x

Plots for Zn and Au with Empty subtracted, and compared to weighted spectra.

Note: Au are logged x and y, Zn is only logged x.

Entry  Wed Nov 15 13:40:50 2023, Claudia, Determination of neutron capture yield and related corrections evalFlux_prelim.rootnTOF-Ph2_fluence_2009-2011_6Dec2011.rootBIF_2011_norm.rootenergyandyield.c

Here are all the files needed for calculation of the yield. There is some information that still needs to be added to the energyandyield.c file, for example the atomic mass of your target in amu, the neutron separation energy for the compound nucleus in MeV (this is needed due to using the Weighting technique). Also, you need to add some lines  to read the tof histogram, which will then be converted in a neutron energy hisogram and then divided by the flux.

For the conversion to neutron energy we assume an approximate flight path for now. We will determine this more accurately once we have the yields and fit resonances. Emma will need to use a different flux than Annie, because we have a different spallation target. Emma's flux is preliminary, so we also should look at the SILI detectors at some point.

There are some more instances where names for rootfiles and ascii files need to be added. In the first instance, please try and add the missing information and try running the code. I haven't tested it so there may be still problem.  To run it you will need to download the 3 rootfiles into the same folder (or move somewhere else and adjust the path name in the .c file.

PLEASE set variable THRESHSCALER to 1 for now. We dont know yet what it is :-)

Entry  Wed Nov 8 11:47:44 2023, AR, Zn68 TTOFSort codes 6x
 
Entry  Tue Nov 7 13:21:51 2023, Emma Walker, Si-30: Comparison between background corrected and uncorrected  Comp_backgroundsub_Si_1.pdfComp_backgroundsub_Au20_1.pdfComp_backgroundsub_Au22_1.pdfComp_backgroundsub_Sinatgood_1.pdf

Below are graphs for the comparison between background corrected and uncorrected spectra (weighted) for Si-30, Au20, Au22 and Sinatgood.

This is just for C6D6 detector 1 but all detectors are consisitent. All histograms have been rebinned by 100 for clarity. 

Entry  Mon Nov 6 11:13:11 2023, Emma Walker, Comparison of empty, ambient and sample- Si-30 16x

Below are graphs for each sample (weighted) showing the comparison between ambient spectra, empty/dummy holder and sample spectra. 

All four detectors are shown for each sample (Si-30, Au20, Au22, Sinatgood). 

All histograms have been rebinned by 50. 

Entry  Fri Oct 27 17:13:58 2023, Emma Walker, Si-30: Dedicated vs Parasitic before and after removal of ambient  14x

Below are histograms for the weighted spectra (with deadtime correction) with and without ambient for C6D6 detector 1.

For each sample the histogram with ambient is first and then without ambient (please ignore histogram titles). 

The Dummy, Empty and C-nat have been rebined by combining 100 to 1.

The Au20, Au22, Si-30 and Sinatgood have been rebined by combining 10 to 1.

Si-30 WF used for: Si-30, Dummy, Empty, C-nat

Au20 WF used for: Au20

Au22 WF used for: Au22

Sinatgood WF used for: Sinatgood

Entry  Tue Oct 24 11:29:46 2023, AR, Weighted Histograms Vs Deadtime*Corrected: 68Zn  24x
 
Entry  Mon Oct 23 12:47:16 2023, Emma Walker, Si-30 weighted and corrected spectra and deadtime correction histograms (parasitic) 8x

Si-30:

Histograms for deadtime correction for all 4 C6D6 detectors for parasitic beam.

Histograms for weighted and deadtime corrected parasitic spectra. 

Entry  Mon Oct 23 12:39:33 2023, Emma Walker, Si-30 corrected weighted and dead time corrections histograms (dedicated) 8x

Si-30:

Histograms for dead time corrections for all 4 C6D6 detectors.

Histograms for weighted and deadtime corrected dedicated spectra. 