AIDA GELINA BRIKEN nToF CRIB ISOLDE CIRCE nTOFCapture DESPEC DTAS EDI_PSA 179Ta CARME StellarModelling DCF K40
  nTOFCapture, Page 1 of 4  ELOG logo
Entry  Thu Jul 13 14:19:37 2023, Claudia, dead time 30Si run consecutiveau22.pdf
Default TTOFSort dead time setting of 30 ns is ok.
Entry  Mon Oct 28 16:15:32 2019, Ruchi, Zn68 measurement setup IMG_3009.JPGIMG_3010.JPG
 
Entry  Wed Nov 8 11:47:44 2023, AR, Zn68 TTOFSort codes 6x
 
Entry  Tue Apr 16 15:24:45 2024, AR, Zn68 Analysis: Au resonance SAMMY fits Au_4ev_yield_sammy_fit_det1.pdfAu_45-48ev_sammy_fit_det1.pdfAu_59-62ev_sammy_fit_det1.pdfAu_78ev_sammy_fit_det1.pdfAu_107ev_sammy_fit_det1.pdf
 
Entry  Fri Mar 1 14:35:04 2024, AR, Zn updated wartime v weighted plots 13x
Updated plots with new WFs. Rebinned by 10.
Entry  Mon Sep 9 11:06:19 2024, AR, Zn update slides 06/08/2024 update_zn68.pdf
 
Entry  Mon Oct 7 14:07:26 2024, AR, Zn update slides 04/10 update_zn68.pdf
Models Vs Resonance amp spectra 
Entry  Fri Aug 4 10:45:05 2023, Annie, Zn Plots: Normalised Spectra, Ratio Plots, Integral/Protons vs Cut (all dets) 27x
All plots in the ratios all look pretty contstant. Zn1 for all detectors seems to have some strange spike in the integral, and a dip in the SILI measurements
(and therefore in the SILI/PKUP ratio). 

Det1 & Det4 dont look great for the Integral/Proton plots, im planning to make these plots with the PKUP protons and SILI and then comapre
Entry  Thu Nov 30 14:43:28 2023, AR, Zn + Au Background subtraction: Plots 21x
Plots for Zn and Au with Empty subtracted, and compared to weighted spectra.

Note: Au are logged x and y, Zn is only logged x.
Entry  Tue Oct 24 11:29:46 2023, AR, Weighted Histograms Vs Deadtime*Corrected: 68Zn  24x
 
Entry  Tue Feb 27 11:37:39 2024, AR, Updated Au Deadtime Corrected Spectra & Weighted Spectra Plots  12x
Plots made with new weighting functions. All rebinned by 10.

Attatchments 1-4: Detector 1.

Attatchments 5-8: Detector 2.
Entry  Fri Aug 7 10:39:18 2020, Ruchi, TTOFSort processing macro and files path 
/eos/user/r/rugarg/public/2017_10_ng_ZnSe/

Latest 4 processing scripts:
1. process_runs_Au1_Jul20.C = Au runs (Se78 part), empty holder runs (Se78 part), and beam-off runs (Se78 part) processed with Au weighting
Entry  Mon Sep 14 13:47:26 2020, Nikolay Sosnin, Summed WF: Monday Meeting 14.09.2020 Sum_Spectra.pptx
 
Entry  Mon Jul 17 10:06:35 2023, Nikolay Sosnin, State of the Union: Campaign Update 17.07.2023 Sinat_PostFall.JPGEAR2_30Si_Alignment.JPGEAR2_30Si.JPG
EAR1: Si-nat sample fell off the holder during maintenance (before run 116544), appears intact and undamaged. Placed it back in-beam for further EAR1
measurements and subsequent transfer to EAR2.

EAR2: Replaced DUMMY with 30Si. Photo during alignment and photo of sample in holder attached.
Entry  Mon Jul 17 12:30:28 2023, Nikolay Sosnin, Si-nat Goodfellow Sample Properties Sinat_Sample_Properties.JPG
Goodfellow sample has been deposited on a single Mylar foil and glue is drying.

mass = 2.932 g

diameter = 20.0 mm
Entry  Fri Oct 27 17:13:58 2023, Emma Walker, Si-30: Dedicated vs Parasitic before and after removal of ambient  14x
Below are histograms for the weighted spectra (with deadtime correction) with and without ambient for C6D6 detector 1.

For each sample the histogram with ambient is first and then without ambient (please ignore histogram titles). 

The Dummy, Empty and C-nat have been rebined by combining 100 to 1.
Entry  Tue Nov 7 13:21:51 2023, Emma Walker, Si-30: Comparison between background corrected and uncorrected  Comp_backgroundsub_Si_1.pdfComp_backgroundsub_Au20_1.pdfComp_backgroundsub_Au22_1.pdfComp_backgroundsub_Sinatgood_1.pdf
Below are graphs for the comparison between background corrected and uncorrected spectra (weighted) for Si-30, Au20, Au22 and Sinatgood.

This is just for C6D6 detector 1 but all detectors are consisitent. All histograms have been rebinned by 100 for clarity. 
Entry  Mon Oct 23 12:47:16 2023, Emma Walker, Si-30 weighted and corrected spectra and deadtime correction histograms (parasitic) 8x
Si-30:

Histograms for deadtime correction for all 4 C6D6 detectors for parasitic beam.

Histograms for weighted and deadtime corrected parasitic spectra. 
Entry  Mon Oct 23 12:39:33 2023, Emma Walker, Si-30 corrected weighted and dead time corrections histograms (dedicated) 8x
Si-30:

Histograms for dead time corrections for all 4 C6D6 detectors.

Histograms for weighted and deadtime corrected dedicated spectra. 
Entry  Tue Mar 26 11:04:29 2024, AR, Si-29 and Si-28 sample images and info 11x
Sample information Excel sheet attached below.

Images 1-6: Si-29 sample

Images 6-10: Si-28 sample
ELOG V3.1.4-unknown