AIDA GELINA BRIKEN nToF CRIB ISOLDE CIRCE nTOFCapture DESPEC DTAS EDI_PSA 179Ta CARME StellarModelling DCF K40
  nTOFCapture, Page 3 of 4  ELOG logo
Entry  Fri Oct 27 17:13:58 2023, Emma Walker, Si-30: Dedicated vs Parasitic before and after removal of ambient  14x
Below are histograms for the weighted spectra (with deadtime correction) with and without ambient for C6D6 detector 1.

For each sample the histogram with ambient is first and then without ambient (please ignore histogram titles). 

The Dummy, Empty and C-nat have been rebined by combining 100 to 1.
Entry  Mon Nov 6 11:13:11 2023, Emma Walker, Comparison of empty, ambient and sample- Si-30 16x
Below are graphs for each sample (weighted) showing the comparison between ambient spectra, empty/dummy holder and sample spectra. 

All four detectors are shown for each sample (Si-30, Au20, Au22, Sinatgood). 

All histograms have been rebinned by 50. 
Entry  Tue Nov 7 13:21:51 2023, Emma Walker, Si-30: Comparison between background corrected and uncorrected  Comp_backgroundsub_Si_1.pdfComp_backgroundsub_Au20_1.pdfComp_backgroundsub_Au22_1.pdfComp_backgroundsub_Sinatgood_1.pdf
Below are graphs for the comparison between background corrected and uncorrected spectra (weighted) for Si-30, Au20, Au22 and Sinatgood.

This is just for C6D6 detector 1 but all detectors are consisitent. All histograms have been rebinned by 100 for clarity. 
Entry  Fri Nov 3 11:19:53 2017, Claudia, Sample Preparation Se-77.pdfSe-78.pdfZn-68.pdf
77Se: m=0.9916 g; D= 20 mm

OLD: 77Se: m=0.919 g according to ntofdaq page. D~ 20 mm NEEDS TO BE CONFIRMED

78Se: m=1.989/pm0.001 g; D=20.09mm; t~1.7 mm
Entry  Fri Nov 3 11:22:43 2017, Claudia, Detector Configuration fig1.jpgfig2.jpgfig3.jpg
Distance Sample to Detector: Det1: ~10.5 cm, Det2: 11 cm, Det3: 11 cm, Det4: 11 cm

 
Entry  Fri Nov 3 15:06:51 2017, Claudia, Measurement Schedule updated measurementplan_new.pdf
 
Entry  Fri Jul 3 14:01:38 2020, Claudia, Link to Ruchi's list of runs + description 
 https://docs.google.com/spreadsheets/d/1W1T2rC10UtOtrAaT8-ZAKFvX70v2PwDk_4-goYL-brI/edit?usp=sharing
Entry  Tue Apr 11 14:07:43 2023, Claudia, Photos of the Zn68 measurement setup IMG_20180409_204846530_LL.jpgIMG_20180409_204854032_LL.jpgIMG_20180410_180042179_LL.jpgIMG_20180411_140834699_LL.jpgZn68measurement.jpg
Photos of the  68Zn(n,gamma) measuremement setup at n_TOF EAR-1.
Entry  Thu Jul 13 14:19:37 2023, Claudia, dead time 30Si run consecutiveau22.pdf
Default TTOFSort dead time setting of 30 ns is ok.
Entry  Mon Jul 17 11:30:54 2023, Claudia, Properties Silicon powder samples 
30Si
Mass: 0.9925(1) g;    Diameter: 22.22(1) mm;    Thickness: 1.77(4) mm;

natSi
Entry  Wed Nov 15 13:40:50 2023, Claudia, Determination of neutron capture yield and related corrections evalFlux_prelim.rootnTOF-Ph2_fluence_2009-2011_6Dec2011.rootBIF_2011_norm.rootenergyandyield.c
Here are all the files needed for calculation of the yield. There is some information that still needs to be added to the energyandyield.c file, for
example the atomic mass of your target in amu, the neutron separation energy for the compound nucleus in MeV (this is needed due to using the Weighting
technique). Also, you need to add some lines  to read the tof histogram, which will then be converted in a neutron energy hisogram and then divided
Entry  Thu Apr 4 09:50:36 2024, CLW, First Si analysis 2024 run 6x
Au and Si29 runs normalised by proton number show consistency (dedicated pulses, example detector 4). Plots for tof spectra zooming on one resonance
and histogram of counts in this resonance divided by protons with statistical errors.

Plots were produced with the macros attached.
Entry  Fri Jun 7 15:58:24 2024, CLW, ISOFLEX Certificates for enriched Si samples Si30_isoflex.pdf231226-01_-_Shipping_Documents(1).pdf
Isoflex certificates for enriched silicon samples
Entry  Thu Jun 15 09:57:01 2023, Annie, Si Set Up 12x
Si Set up images and documentation.

Detector 1 - C6D6D: Distance= 9 cm, Angle= 135 deg relative to BL (check set up pdf for drawing if unsure), Voltage= 1550 V

Detector 2 - C6D6E: Distance= 9 cm, Angle= 135 deg relative to BL, Voltage= 1590 V
Entry  Thu Jun 22 10:37:39 2023, Annie, Gold 22mm Sample Images IMG_2187.JPGIMG_2186.JPGIMG_2185.JPG
New 22mm sample compared to old 20mm sample used at the beginning of the campaign + picture of dummy target in the setup.
Entry  Thu Jun 29 09:21:13 2023, Annie, Info on Samples IMG_2242.JPGIMG_2248.JPGIMG_2247.JPGIMG_2246.JPG
Both Au samples (20mm and 22mm) are single mylar.

Both Si30 (22mm) and natSi (20mm) are double mylar.

Empty is single mylar ONLY
Entry  Fri Aug 4 10:45:05 2023, Annie, Zn Plots: Normalised Spectra, Ratio Plots, Integral/Protons vs Cut (all dets) 27x
All plots in the ratios all look pretty contstant. Zn1 for all detectors seems to have some strange spike in the integral, and a dip in the SILI measurements
(and therefore in the SILI/PKUP ratio). 

Det1 & Det4 dont look great for the Integral/Proton plots, im planning to make these plots with the PKUP protons and SILI and then comapre
Entry  Tue Oct 24 11:29:46 2023, AR, Weighted Histograms Vs Deadtime*Corrected: 68Zn  24x
 
Entry  Wed Nov 8 11:47:44 2023, AR, Zn68 TTOFSort codes 6x
 
Entry  Thu Nov 30 14:43:28 2023, AR, Zn + Au Background subtraction: Plots 21x
Plots for Zn and Au with Empty subtracted, and compared to weighted spectra.

Note: Au are logged x and y, Zn is only logged x.
ELOG V3.1.3-7933898