7 June 2017   

00:05  All system-wide checks are passed
       Sync pulses nera 44 x 10^6
       Memory 35k ~ 38k
       Biases uploaded as 33.png, 34.png - attachments 1 & 2
          Entered into spreadsheet
          SSD 3 bias is going up slowly since this isotope setting began
       Around "2 to 4" Hz in SSDs 3 and 4 -> 50 to 80 pps implant rate
          See attachment 3, 35.png
       All rates under 100k except nnaida 13, 21
          See attachment 4, 36.png
       FEE temperatures shown as 37.png, attachment #5

00:30  BRIKEN number 32, AIDA R6_299, BigRIPS 3032

01:01  Timewarps look okay (only 2 MBS seen in FEE 6)
          See R6_307 - attachment #6

01:30  BRIKEN and BigRIPS runs stopped.  AIDA R6_317 at that time.

01:31  AIDA R6_318, BRIKEN run #33, BigRIPS #3033

       All system-wide checks passed.
       SYNC pulses 46 x 10^6
       Memory 35 ~ 39k

02:08  Biases shown as 38.png, attachment #7

02:34  AIDA run R6_337 when BRIKEN and BigRIPS runs are stopped.

AIDA passes all system-wide checks.

02:37  AIDA just begins R6_338l.  BRIKEN run #34, BigRIPS #3034

Timewarps look okay, see attachment #8, R6_336
Statistics consistent, see attachment #9, 39.png
Implant rate around 75 cps

03:31  AIDA run R6_354 at the stop of BRIKEN and BigRIPS runs


03:34  AIDA R6_355, BRIKEN run #35, BigRIPS #3035

AIDA passed all system checks.  Merger shows low rate for nnaida8, but this is consistent for tonight.

4:03 Biases shown as 40.png, attachment #10.

4:08 Stats shown as 41.png, attachment #11
     As before, only nnaida13 and nnaida21 show over 100k, and nnaida8 is quite low.

4:30 AIDA run R6_372 at the close of BRIKEN and BigRIPS runs.

4:32 AIDA R6_373 with new BRIKEN run #36 and BigRIPS #3036.
     All system-wide checks okay.

5:38 AIDA R6_393 at the stop of BRIKEN and BigRIPS runs
     All system-wide checks okay.

5:39 AIDA still R6_393, BRIKEN run #37 and BigRIPS run #3037

6:00 Leak currents shown as 42.png, attachment #12

6:16 Beam stopped so we can check the signal of one Ge detector that became noisy
     R6_404 at that time
     Added some Al foil to the Ge signal cables

6:28 Beam is back R6_408

6:29 BRIKEN run #41, BigRIPS #38

7:28 AIDA R6_426 at stop of other runs
     System-wide checks are okay.

7:30 AIDA R6_427.  BRIKEN #42, BigRIPS #39
     Implant rates 60 ~ 70 cps in AIDA
     One MBS timewarp in R6_426, as attachment #13

7:57 Leak currents shown as attachment #14, 43.png
Attachment 1: 33.png  12 kB  Uploaded Tue Jun 6 17:07:54 2017  | Hide | Hide all | Show all
33.png
Attachment 2: 34.png  12 kB  Uploaded Tue Jun 6 17:07:54 2017  | Hide | Hide all | Show all
34.png
Attachment 3: 35.png  402 kB  Uploaded Tue Jun 6 17:07:54 2017  | Hide | Hide all | Show all
35.png
Attachment 4: 36.png  92 kB  Uploaded Tue Jun 6 17:07:54 2017  | Hide | Hide all | Show all
36.png
Attachment 5: 37.png  134 kB  Uploaded Tue Jun 6 17:07:54 2017  | Hide | Hide all | Show all
37.png
Attachment 6: R6_307  11 kB  Uploaded Tue Jun 6 18:02:05 2017  | Show | Hide all | Show all
Attachment 7: 38.png  25 kB  Uploaded Tue Jun 6 19:09:19 2017  | Hide | Hide all | Show all
38.png
Attachment 8: R6_336  11 kB  Uploaded Tue Jun 6 19:38:57 2017  | Show | Hide all | Show all
Attachment 9: 39.png  59 kB  Uploaded Tue Jun 6 19:40:31 2017  | Hide | Hide all | Show all
39.png
Attachment 10: 40.png  25 kB  Uploaded Tue Jun 6 21:05:15 2017  | Hide | Hide all | Show all
40.png
Attachment 11: 41.png  59 kB  Uploaded Tue Jun 6 21:09:05 2017  | Hide | Hide all | Show all
41.png
Attachment 12: 42.png  25 kB  Uploaded Tue Jun 6 23:01:11 2017  | Hide | Hide all | Show all
42.png
Attachment 13: R6_426  10 kB  Uploaded Wed Jun 7 00:35:49 2017  | Show | Hide all | Show all
Attachment 14: 43.png  24 kB  Uploaded Wed Jun 7 00:58:06 2017  | Hide | Hide all | Show all
43.png
ELOG V3.1.4-unknown