AIDA GELINA BRIKEN nToF CRIB ISOLDE CIRCE nTOFCapture DESPEC DTAS EDI_PSA 179Ta CARME StellarModelling DCF K40 MONNET
  AIDA, Page 35 of 46  ELOG logo
Entry  Thu Oct 6 13:22:24 2016, TD, Images of setup at F11 - 4 IMG_6702.JPG
 
Entry  Thu Oct 6 13:20:34 2016, TD, Images of setup at F11 - 3 IMG_6695.JPGIMG_6696.JPGIMG_6701.JPG
 
Entry  Thu Oct 6 13:09:50 2016, TD, Images of setup at F11 - 2 IMG_6692.JPGIMG_6693.JPGIMG_6694.JPG
 
Entry  Thu Oct 6 12:39:14 2016, TD, Images of setup at F11 IMG_6687.JPGIMG_6689.JPGIMG_6690.JPG
 
Entry  Wed Dec 3 12:13:03 2014, Alfredo Estrade, IV curve with CAEN N1419 IV_dec14.PNG
Measured IV curve for BB18 DSSD with new CAEN HV supply. Settings as in previous elog entry:

Detector bias CAEN N1419 Programmable HV Power Supply
Entry  Sun Feb 15 06:12:00 2015, TD, AEV & CG, How to mount USB disk with NTFS 

Mount external USB expansion disk with NTFS filesystems 
with the (superuser) command:
Entry  Sat Jun 11 13:57:09 2016, laura, How to monitor and check synchronisation of FEES eg1.pngeg2.pngeg3.pngeg4.png
Alfredo has written a program to check the synchronisation of the FEES, which need to be checked regularly
 
To do this:
Entry  Mon May 4 02:32:29 2015, VFEP & TD, How to fix DAQ stalls at GO 
It has been observed that when starting the AIDA data acquisition (select 'GO' from the 'Data Acquisition Run
Control' window) that from time to time one, or possibly more, FEE64 modules fail to begin producing data.
Once running they appear to be totally reliable. 
Entry  Fri Feb 20 10:48:09 2015, TD, How To Connect the FEE64 System Console Using PuTTY 

Set permissions for the USB-serial device using the command
Entry  Sat Sep 30 16:37:06 2023, TD, Honeywell HSS-DPS fault 

The Honeywell HSS-DPS dew point sensor indicator ( red LED ) is flashing c. 0.5Hz indicating humiidity > 90+/-3 %
Entry  Tue Feb 10 16:01:50 2015, Chris Griffin, Alfredo Estrade, High data rate - Pause/Resume 6x
06/02/15
 A look at the data rate at which Pause/Resumes start to cause missing data.
Pulser settings:
Entry  Thu Apr 30 15:28:25 2015, Patrick Coleman-Smith, High Energy Spectra from LYCCA with pulser LYCCA_High_Energy.png
I have an eight FEE64 system now in place on the LYCCA chamber with a PB-5 pulser going into the adapter cards test input. The test capacitor is 30pF.
I was going to explore the effect of the thresholds on the pulser peak.
I notice that the spectra look like those taken in RIKEN and not a single peak. In the 1GeV range I would interpret this as noise but since this
    Reply  Thu Apr 30 17:43:36 2015, Patrick Coleman-Smith, High Energy Spectra from LYCCA with pulser 
I have an eight FEE64 system now in place on the LYCCA chamber with a PB-5 pulser going into the adapter cards 
test input. The test capacitor is 30pF.
    Reply  Thu Apr 30 20:21:20 2015, Patrick Coleman-Smith, High Energy Spectra from LYCCA with pulser 
> I have an eight FEE64 system now in place on the LYCCA chamber with a PB-5 pulser going into the adapter cards 
> test input. The test capacitor is 30pF.
Entry  Fri Nov 16 06:01:47 2018, CA, High Energy Channel Ex vs Ey for different degrader thicknesses 2_3HECexey.png2_8HECexey.png3_0HECexey.png3_3HECexey.png
15.04 Plots of X Energy vs Y Energy for each detector, and for 4 different Al degrader thicknesses, as indicated
on each graph. (Attachments 1-4)
Entry  Tue Jun 7 05:48:13 2016, TD, AE, ML & PJW, HEC spectra & implant profile 30.png36.png40.png

DSSSD#1 and DSSSD#6 ADC hit patterns (profile) and 1*H (ASIC#1 20GeV FSR) energy spectra 
Entry  Thu Jun 13 05:49:37 2019, CA, Further tests of calibration on Alpha data 27x
Alpha data used: /May19/{R1,R2,R7,R8,R9,R11} (c. 380 hr.)

Absolute calibration calculated with relative calibrated data
Entry  Thu Jan 22 13:50:33 2015, Alfredo and Tom, Further measurements with filtered PSU 
Jan 20, 2015

Test settings: DSSD biased at 100V, with 3.5 uA leakage current. Pulser at 0.5 V, split and inverted for both
Entry  Thu Mar 30 16:12:21 2017, DK, OH, CG, Friday, March 31 run status 14x
00:11 BigRIPS has started a new run at 00:10:42 run 0165.
      AIDA subrun R16_357 was about halfway (~1 GB) at 00:11.
      BRIKEN run 21 ( so-called 170331_0012_Mg40 )
Entry  Fri May 5 08:03:36 2017, OH, TD, Friday May 5th 10x
Relatively painless start-up. Had an issue with firefox where all bookmarks had been forgotten.
All drop down menues in the DAQ did not work.
Kill all firefox processes to restore.
ELOG V3.1.3-7933898