AIDA GELINA BRIKEN nToF CRIB ISOLDE CIRCE nTOFCapture DESPEC DTAS EDI_PSA 179Ta CARME StellarModelling DCF K40
  BRIKEN  ELOG logo
Message ID: 87     Entry time: Fri Oct 14 04:42:40 2016
Author: JL Tain et al 
Subject: Electronics 
Change of main power line for MPOD and CLOVER preamp


Because the incident yesterday with the NIM crate,
we try to separate the CLOVER from the rest of 
the equipment.

So we put the MPOD, which powers the CLOVER but also
the 3He tubes and the VETO detectors, and the preamp
power supply in a different line.

We check if this has an impact on the noise in either
CLOVER or 3He tubes.

We measure with the 137Cs-60Co source:
File: 161014_1241_137Cs60Co.root

After inspecting the spectra we conclude that the impact
is not appreciable.

See figures 

662keV resolution:
D4Black: 3.16keV
D4Red: 2.49keV
D4Green: 3.57keV
D4Blue: 3.40keV
Attachment 1: D4All-CsCo-zoom-newlineCL.pdf  28 kB  Uploaded Fri Oct 14 05:58:01 2016  | Hide | Hide all
D4All-CsCo-zoom-newlineCL.pdf
Attachment 2: BRIKEN-newlineCL.pdf  18 kB  Uploaded Fri Oct 14 05:58:12 2016  | Hide | Hide all
BRIKEN-newlineCL.pdf