AIDA GELINA BRIKEN nToF CRIB ISOLDE CIRCE nTOFCapture DESPEC DTAS EDI_PSA 179Ta CARME StellarModelling DCF K40
  BRIKEN, Page 12 of 21  ELOG logo
Entry  Sat Jul 9 21:26:25 2016, J.L. Tain, EDACQ EDACQ-July2016.pdf
Electronics and DACQ for July 2016 assembly: hardware and connections
Entry  Mon Jul 18 19:01:36 2016, J.L. Tain, 3He tubes 
Adjustment of HV and PA gain

We adjust the HV for each tube type and the gain of the preamplifier (PA) in order
Entry  Wed Jul 20 11:16:18 2016, J.L. Tain, Electronics 
Pulser settings

We use two pulsers, Pulser1 for RIKEN, ORNL1 and ORNL2 tubes (7 PA)
Entry  Fri Jul 22 12:50:29 2016, J.L. Tain, END 
20/JUL/2016 20:00 
End of the test measurements
Entry  Mon May 4 15:03:47 2015, J.Agramunt J.L.Tain K.Gabor , New detector placed under the beam line photo_2-2.JPGphoto_1-2.JPGphoto_3-2.JPG
 New detector placed under the beam line, below MUSIC chamber
This detector replace the USA tubes in the DACQ because we need the preamp to plug it.
 
Entry  Mon May 4 02:26:14 2015, J.Agramunt J.L.Tain K.Gabor, F11 trigger plugged in Mod2 Ch16 of Briken daq 
 
Entry  Mon May 4 02:36:16 2015, J.Agramunt J.L.Tain K.Gabor, Maki trigger plugged in Mod2 Ch9 
 
Entry  Mon May 4 04:14:18 2015, J.Agramunt J.L.Tain K.Gabor, AIDA trigger plugged in Mod2 Ch12 
AIDA trigger plugged in Mod2 Ch12
Entry  Fri May 8 03:20:48 2015, J.Agramunt J.L.Tain K.Gabor, BnCorrelation BnCorr.pdf
We run all the night until the end of beam time, and the Bn correlations are more clear now.
Entry  Thu Mar 30 01:46:30 2017, J.Agramunt, 40Mg Run 009 
 Date: 30/03/2017

Start: 09:47
Entry  Tue Feb 24 09:34:54 2015, J. Agramunt, H. Baba, A. Estrade, [DAQ] DAQ correlation test  DAQcorrelation_diagram.pdfDAQsoftware.pdfcorrelation_25Hz.pngcorrelation_random.png

We have performed a successful test of the integration of independent DAQ systems based on a correlation 
scalar counted from a common clock signal. The principles of the integration method are described in the 
Entry  Wed Jul 20 17:21:59 2016, J. Agramunt, A. Tolosa, DACQ 160718Conf_BrikenFull_cal5.xlsx
DACQ configuration parameters

The last configuration file used was: 160718Conf_BrikenFull_cal5.xlsx
Entry  Wed May 6 11:41:24 2015, J. Agramunt, A. Estrade, First online combined analysis Screenshot_from_2015-05-06_19_12_29.png
Screen shot of the rudimentary on-line
analysis of the combined data:
BRIKEN-AIDA-BigRIPS
Entry  Mon Oct 31 23:56:37 2016, J. Agramunt, First AIDA BRIKEN correlation plot FirstAIDA_BRIKENPlot.pdf
From the 252Cf data.
Entry  Wed Mar 29 03:02:02 2017, J. Agramunt, Synchronization test procedure (update)  
To Launch the processes:

Open 4 terminals:
Entry  Wed Mar 29 07:34:16 2017, J. Agramunt, BrikenTools repository installed at d05 
The last version of Briken tools repository has ben installed at d05, this repository includes the Merger and the BrikenOffline codes, as well as a CommonTools
folder to share scripts and code.

For update versions, just type in the desired directory "svn update".
Entry  Wed Mar 29 22:53:58 2017, J. Agramunt, 40Mg Run007 

 Date: 30/03/2017
Entry  Thu Mar 30 00:47:04 2017, J. Agramunt, 40Mg Run 008 
 Date: 30/03/2017

Start: 08:41
Entry  Thu Mar 30 03:55:42 2017, J. Agramunt, 40Mg Run 10 
Date: 30/03/2017

Start: 11:52
Entry  Fri May 26 09:07:46 2017, J. Agramunt, Synchronization Monitoring synchroCheck.pngSynchronizationMonitoring.pdf
We started the synchronization monitoring programs to check that
it is OK as can be seen in the figure below
ELOG V3.1.3-7933898