Power, Ethernet and HDMI cables connected to FEEs. To prevent cables coming out of connectors, power and HDMI cables are zip tied to FEE cooling pipe (see attached image).
Correct FEE MAC addresses have been updated in /etc/dhcp/dhcpd.conf
Remote access to carme sever has been setup. Remote access instructions in elogs 176-179.
New ASIC settings which reflect polarity of FEES produced 2022Jan27-16-43-00
New Options file updated to point to new ASIC settings.
/MIDAS/config/TclHttpd/carme-gsi@8015/startup.tcl updated for 8 FEEs
/MIDAS/Linux/startup/NewMerger Updated line from "./master64 -i 16 -l 16 -p 11001 &" to "./master64 -i 8 -l 16 -p 11001 &"
Quick motors test performed. Motors accesible remotely (elog 179). Motors moving output (BNC 1 on motors box) connected to motors module (BNC 1). When not moving +12V is observed at BNC 2 on motors module. When moving 0V is observed on BNC 2. |