AIDA
GELINA
BRIKEN
nToF
CRIB
ISOLDE
CIRCE
nTOFCapture
DESPEC
DTAS
EDI_PSA
179Ta
CARME
StellarModelling
DCF
K40
|
DESPEC |
 |
|
Message ID: 259
Entry time: Wed Apr 21 23:05:39 2021
|
Author: |
CA |
Subject: |
22nd April 00:00 - 08:00 |
|
|
00:07 stats/ucesb/DB checks all ok
00:30 all system wide checks ok *except* fpga errors
Base Current Difference
aida12 fault 0x0 : 0x1f : 31
FPGA Timestamp error counter test result: Passed 11, Failed 1
If any of these counts are reported as in error
The ASIC readout system has detected a timeslip.
That is the timestamp read from the time FIFO is not younger than the last
statistics ok - attachment 1
temperatures ok - attachment 2
detector bias / leakage currents ok - attachment 3
no error messages in DB terminal & ucesb ok - attachment 4
01:00 stats/ucesb/DB checks all ok
01:30 stats/ucesb/DB checks all ok
01:53 issues with beam dropping in and out - ESR working to stabilise this
02:00 stats/ucesb/DB checks all ok
02:09 beam back in a stable state
02:30 all system wide checks ok *except* fpga errors
Base Current Difference
aida12 fault 0x0 : 0x29 : 41
FPGA Timestamp error counter test result: Passed 11, Failed 1
If any of these counts are reported as in error
The ASIC readout system has detected a timeslip.
That is the timestamp read from the time FIFO is not younger than the last
02:33 statistics ok - attachment 5
temperatures ok - attachment 6
detector bias / leakage currents ok - attachment 7
no error messages in DB terminal & ucesb ok - attachment 8
02:45 beam off - potentially serious issue, awaiting update from FRS
03:00 significant issues with UNILAC, beam not expected back for a while
03:05 stats/ucesb/DB checks all ok
03:32 stats/ucesb/DB checks all ok
03:55 beam is back
04:00 stats/ucesb/DB checks all ok
04:30 all system wide checks ok *except* fpga errors
Base Current Difference
aida12 fault 0x0 : 0x2b : 43
FPGA Timestamp error counter test result: Passed 11, Failed 1
If any of these counts are reported as in error
The ASIC readout system has detected a timeslip.
That is the timestamp read from the time FIFO is not younger than the last
04:32 statistics ok - attachment 9
temperatures ok - attachment 10
detector bias / leakage currents ok - attachment 11
no error messages in DB terminal & ucesb ok - attachment 12
05:00 stats/ucesb/DB checks all ok
05:30 stats/ucesb/DB checks all ok
06:00 stats/ucesb/DB checks all ok
06:30 all system wide checks ok *except* fpga errors
Base Current Difference
aida12 fault 0x0 : 0x34 : 52
FPGA Timestamp error counter test result: Passed 11, Failed 1
If any of these counts are reported as in error
The ASIC readout system has detected a timeslip.
That is the timestamp read from the time FIFO is not younger than the last
06:32 temperatures ok - attachment 13
statistics ok - attachment 14
detector bias / leakage currents ok - attachment 15
no error messages in DB terminal & ucesb ok - attachment 16
07:00 stats/ucesb/DB checks all ok
07:30 stats/ucesb/DB checks all ok
07:59 stats/ucesb/DB checks all ok
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|