DESPEC |
 |
|
Message ID: 342
Entry time: Fri May 21 15:03:48 2021
|
Author: |
CA |
Subject: |
Friday 21st May 16:00 - 00:00 shift |
|
|
16:00 CA takes over
DSSD1 n+n sides 0x20 on ASICs 1-3 and 0x64 on ASIC 4
DSSD2 n+n sides 0x1b on ASICs 1-3 and 0x64 on ASIC 4
PULSER SETTINGS
---------------------------
Pulse is ON
Positive Tail Pulse
Trigger Source is Internal Clock
Trigger Threshold is 3.5
Amplitude : 2.0 Volts
Rep Rate : 2.0 hZ
Delay : 250.0 ns
Fall Time : 1 ms
Attenuation : 1
Display is : Volts
Equivalent keV is : 200.0
Ramp Start at 0.01 Volts
Ramp Stop at 9.99 Volts
Ramp Start at 1.0 keV
Ramp Stop at 999.0 keV
Ramp Time is 60 seconds
# Ramp Cycles is 1
16:14 system wide checks all ok *except*
Base Current Difference
aida05 fault 0x500 : 0x570 : 112
White Rabbit error counter test result: Passed 15, Failed 1
Understand the status reports as follows:-
Status bit 3 : White Rabbit decoder detected an error in the received data
Status bit 2 : Firmware registered WR error, no reload of Timestamp
Status bit 0 : White Rabbit decoder reports uncertain of Timestamp information from WR
16:17 temperatures ok - attachment 1
statistics ok - attachment 2
detector bias / leakage currents ok - attachment 3
analysis of R14_1625 - FEE7 deadtime at 4.5%
18:06 system wide checks all ok *except*
Base Current Difference
aida05 fault 0x500 : 0x571 : 113
White Rabbit error counter test result: Passed 15, Failed 1
Understand the status reports as follows:-
Status bit 3 : White Rabbit decoder detected an error in the received data
Status bit 2 : Firmware registered WR error, no reload of Timestamp
Status bit 0 : White Rabbit decoder reports uncertain of Timestamp information from WR
18:07 temperatures ok - attachment 4
statistics ok - attachment 5
detector bias / leakage currents ok - attachment 6
analysis of R14_1662 - FEE7 deadtime at 4.3%
19:07 DAQ continues ok - writing to file R14_1682
20:07 system wide checks all ok *except*
Base Current Difference
aida05 fault 0x500 : 0x572 : 114
White Rabbit error counter test result: Passed 15, Failed 1
Understand the status reports as follows:-
Status bit 3 : White Rabbit decoder detected an error in the received data
Status bit 2 : Firmware registered WR error, no reload of Timestamp
Status bit 0 : White Rabbit decoder reports uncertain of Timestamp information from WR
20:10 temperatures ok - attachment 7
statistics ok - attachment 8
detector bias / leakage currents ok - attachment 9
analysis of R14_1703 - max deadtime at 4.0% - attachment 10
20:35 rate spectra - attachment 11
HEC spectra - attachment 12 & 13
20:36 all histograms zeroed
20:37 DAQ continues ok - writing to file R14_1712
20:45 /media/1e121361-83d3-4825-b6ae-9700b07e0ca7 at 94% use.
~ 12 hours until 100% at 10 MB/s data rate, not accounting for compression of older files
21:12 no beam - writing to file R14_1723
21:17 beam is back
22:07 system wide checks all ok - WR decoder fault same as entry at 20:07
22:08 temperatures ok - attachment 14
statistics ok - attachment 15
detector bias / leakage currents ok - attachment 16
analysis of R14_1740 - max deadtime at 4.2% - attachment 17
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|