Wed Feb 12 10:46:01 2025, TD, Offline analysis data files S181 R4_351-396 25x
|
Analysis data files R4_351-396
|
Fri Jan 31 17:26:47 2025, CC, TD, MP, Friday 31 January contd. 16x
|
18.18 bPlas and BB7 installs complete
Restart AIDA DAQ, Merger, Tape Server and re-test
|
Fri Jan 31 13:48:29 2025, JB, AIDA analysis from HI-DESPEC meeting 20.11.2024
|
AIDA analysis and presentation by J. Bormans for AIDA made in the HISPEC-DESPEC collaboration meeting.
https://docs.google.com/presentation/d/1hlZ30r294UqbVKGy3jg-wompFpc7TSfD/edit?usp=sharing&ouid=102131181856760114019&rtpof=true&sd=true |
Fri Jan 31 09:37:47 2025, CC, TD, MP, Friday 31 January 26x
|
Implantation stack mounted - BB18(DS)-1000 + bPlas + bPlas + 3x BB7(DS)-1000
N.B. aida02, aida09 & aida15 have grounded copper screen (3M 1245 - aluminimum braid to copper screen of ribbon cables) for Kapton PCBs connecting the |
Wed Jan 15 11:58:08 2025, TD, Offline analysis data files S505 R3_9 - R3_128 (207Hg setting) 27x
|
Aanlysis data files R3_9 - R3_128 (207Hg setting)
|
Mon Jan 13 17:38:18 2025, TD, Offline analysis of S505 data files 10x
|
First timestamp of R2_105 0x16FAEC5E54AABF6C
|
Mon Jan 13 11:32:30 2025, TD, Offline analysis S505 data file R3_150 22x
|
Offline analysis of S505 data files R3_150
first WR ts
|
Sat Jan 11 14:14:21 2025, TD, aida06 crashed and rebooted 10.1.25
|
aida06 crashed and rebooted sometime ( 14:48 - 23:25 ) yesterday. System console log appended.
|
Sat Jan 11 14:05:03 2025, TD, Saturday 11 January 2024 17x
|
14.37 Detector bias & leakage current OK - attachment 1
|
Thu Jan 9 16:25:51 2025, TD, LEC fast comparator threshold too low
|
LEC fast comparator has been set to 0x2 (200keV) which is *very* low and means the fast comparator will be triggering on noise.
|
Thu Jan 9 17:36:50 2025, TD, LEC fast comparator threshold too low
|
>
> LEC fast comparator has been set to 0x2 (200keV) which is *very* low and means the fast comparator will be triggering on noise.
>
|
Thu Jan 9 17:56:14 2025, TD, LEC fast comparator threshold too low
|
> >
> > LEC fast comparator has been set to 0x2 (200keV) which is *very* low and means the fast comparator will be triggering on noise.
> >
|
Fri Jan 10 10:03:43 2025, TD, LEC fast comparator threshold too low
|
> > >
> > > LEC fast comparator has been set to 0x2 (200keV) which is *very* low and means the fast comparator will be triggering on noise.
> > >
|
Thu Jan 9 15:43:17 2025, JB, CC, MP, Timing test platform moved in  
|
16:30 We moved the platform in. The system was still biased and the DAQ was still running.
The system seems to be okay, temperatures OK. Bias voltage OK 685/1 and 685/2. Two FEEs - aida07 and aida12 are receiving a lot of trigger data
items from the fast discriminator. This is already a bit worrying. 685/3 |
Mon Dec 16 13:07:04 2024, JB, MP, CC, AIDA timing test 16x
|
https://elog.gsi.de/despec/Implantation+Stack/9?suppress=1 - Day 1 ELOG
Day2:
10:14 we set up the detector with the pulser in BB7 and started biasing the detector and setting up the DAQ. Water flow and temperature check, |
Tue Dec 17 12:45:36 2024, JB, MP, CC, AIDA timing test  
|
Quote:
https://elog.gsi.de/despec/Implantation+Stack/9?suppress=1 - Day 1 ELOG |
Wed Jan 8 16:47:05 2025, JB, MP, CC, AIDA timing test
|
Quote:
https://elog.gsi.de/despec/Implantation+Stack/9?suppress=1 - Day 1 ELOG |
Thu Jan 9 12:46:43 2025, JB, MP, CC, AIDA timing test   
|
Quote:
|
Wed Jan 8 10:46:50 2025, TD, Report - aida06 -boot fail due to network issue
|
8:01:25/11:42:48|0x000000d00000-0x000000fe0000 : "user_kernel"
08:01:25/11:42:48|0x000000fe0000-0x000001000000 : "env_variables"
08:01:25/11:42:48|xilinx-xps-spi 81400400.hd-xps-spi: at 0x81400400 mapped to 0xD1028400, irq=20
|
Wed Jan 8 10:08:29 2025, JB, GB, SD, MP, CC, JG, AIDA noise test with platform in position   
|
Yesterday we spent time essentially performing a dry run to get AIDA DAQ and bPlast into the time sorter, there were some issues with the AIDA mbs PC
x86l-119 which was related to some boot issue, it was booting to a newer version of debian while the Relay for AIDA to MBS is on an older version (scratch)
(the machine is quite old). We spent a bit of time getting the thresholds correct for each of the ASICs. In the end we just elected to have a blanket level |
Mon Dec 30 15:43:42 2024, TD, [How To] Restart AnyDesk
|
See also https://elog.ph.ed.ac.uk/CARME/489
|
Mon Dec 23 10:54:46 2024, TD, Monday 23 December 2024
|
11.54 re-established remote access via AnyDesk - details to follow
|
Sat Dec 14 11:52:42 2024, TD, Saturday 14 December 27x
|
11:00 Visual inspection FEE64 adaptor PCBs & cabling
aida02 ground from/to other FEE64s disconnected - re-connected
|
Wed Dec 11 14:46:21 2024, TD, JB, CC, MP, Mounting of AIDA, bPlast and BB7 for test   
|
Snout assembled for detector position and timing test.
The planned test is to use a BGO with a 22-Na source and the implantation stack to characterise the timing and position of back-to-back 511 keV
events (proxy for mock beta decay event). |
Mon Dec 9 12:28:01 2024, NH, CC, MP, Test of BB7 on AIDA Electronics
|
BB7 connected to aida07, sitting in a cardboard box
Update Tcl/Tml files in ASIC, ASIC4 and sys.tml frm PJCS email to allow setting per-ASIC polarity on FEE64
|
Thu Dec 5 11:18:46 2024, TD, Offline analysis S100 data files R21_0-R21_99 23x
|
Offline analysis of S100 data files R21_0 - R21_99 (162Eu setting)
first WR ts
|