  117   Tue Jun 11 01:45:55 2019 Pancho, Alebackground
Start: 09:46
 20190611_1349_background_AIDA_in.root 
  1   Tue May 14 09:41:24 2019 TDWelcome to the DTAS Elog    
  127   Sun Jun 16 02:07:29 2019 VictorTotal sum (black) and anodesDifferent cuts at high energy in individual
spectra (anodes) and effect in the total
sum
 SUM_and_individuals_anodes_cut8MeV.pngSUM_and_individuals_anodes_cut20MeV.png 
  143   Mon Jun 17 19:12:33 2019 VictorTotal SUM in coincidence with AIDA PlasticAlso TAC DTAS-Plastic AIDA  Sum_coin_PlasAIDA.pngTAC_SUM_PlasAIDA.png 
  132   Sun Jun 16 07:31:01 2019 VictorThe bump in the mutiplicitiesWe have calculated the spectra of the module
multiplicity for each side (careful! the
maximum is 8, since it is
 8x 
  110   Mon Jun 10 08:07:17 2019 Ale, JoseTest of pulser count ratesFile: 20190610_1602_background_AIDA_in.root

SyncPulse: 61777
 20190610_1602_background_AIDA_in.root 
  142   Mon Jun 17 19:11:06 2019 VictorTAC slowest module vs fastest module DTAS Inside events of 320ns window  TAC_last_module_1st_module.png 
  81   Fri May 31 06:48:58 2019 A. AlgoraT spectra for AIDA and F11 plasticsT spectra for AIDAPL and F11PLL and F11PLR
are defined from now on. The ancilliary card
was not saving the CFD values for all channels.
 20190531_Conf_1.xlsx 
  3   Wed May 15 04:03:23 2019 JARSynchronization with AIDA workingSynchronization with AIDA is working, see
attached document to proceed.
 SyncProcedure.pdf 
  136   Sun Jun 16 22:02:45 2019 VictorSum in coincidence with F11TAC DTAS (slowest module of the sum) and F11

Total sum in coincidence with F11
 TAC_SUM_F11.pngSum_coin_F11.pngSum_coin_F11_for_back.png 
  6   Wed May 15 07:48:08 2019 Kiss Algora NacherSaturation and pulserSaturation and pulser position after calibration

EDy1 16801 25000
 Saturation_pulser.ods 
  42   Thu May 23 04:18:57 2019 A. AlgoraSY2527 fixed Following the instructions of CAEN, the
SY2527 is working again. Some pushing, massaging
appear to solve the situation
  
  62   Tue May 28 05:30:03 2019 A. AlgoraReference detector threshold changedAgain the Reference detector was firing
mainly in the noise. Threshold increased
to 5000 !!!!
 Screenshot_from_2019-05-28_13-29-46.png 
  59   Mon May 27 12:54:48 2019 A. AlgoraReference detectorThe reference detector was very noisy.
The threshold has been changed from 2000
to 3200. We should look at this more carefully.
 Screenshot_from_2019-05-27_20-54-21.png 
  72   Thu May 30 02:03:33 2019 A. AlgoraRef detector position changed, AIDA plastik HV changedThe position of the reference detector
in the ancilliary card was changed from channel
10 to channel 9. Remember that this is important
 20190530_Conf.xlsx 
  70   Wed May 29 09:49:25 2019 A. AlgoraNew configuration fileNew configuration file after a few small
changes in thresholds.
 20190529_Conf.xlsx 
  94   Mon Jun 3 12:56:06 2019 A. AlgoraNew configuration fileThe E range of the AIDA plastic for the
construction of the TAIDA plastic spectrum
has been changed. Also the range of the TAC_AIDAPL_CryA
 20190603_Conf.xlsx 
  19   Mon May 20 06:55:15 2019 A. AlgoraNew config file after calibrationA file with Co and Cs was collected for
10 min

201905201444_137Cs60Co_align.root
  
  84   Fri May 31 14:17:13 2019 A. AlgoraNew config fileA new config file provided by Jose and
Alvaro is loaded

cp 20190531_Conf_JLTAT.xlsx 20190531_Conf_2.xlsx
 20190531_Conf_2.xlsx201905312230_background_AIDA_in.root 
  114   Mon Jun 10 12:31:52 2019 Ale, JoseNew calibrationNew calibration with more statistics
File: 20190610_2030_60Co_137Cs_AIDA_in.root
  