Entry  Wed Nov 8 15:20:17 2023, Selin Ezgi Birincioglu, TALYS Parameters from Different Models models.xlsx

This is the parameters of Ca42+n and Ca50+n acquired from differen models. They were chosen as they have Gaussian distributions which are consistent with TALYS calculations of MACS. Ca42+n has experimental values while Ca50+n does not.

Entry  Mon Nov 6 09:20:53 2023, Selin Ezgi Birincioglu, TALYS including MACS TALYSparameters.xlsx
 
Entry  Sat Nov 4 14:05:19 2023, Selin Ezgi Birincioglu, Maxwellian Cross Section Distribution of Ne22+n macs1.pdfmacs01.pdfmacs11.pdftalys.outNe23run

1. This graph is Ne22+n with a log scale. Theorotical cross section is around 0.05 while the experimental is 0.061, which matches relatively well.

2. This the the distribution of l = 0 with log scale.

3. This the the distribution of l = 1 with log scale.

4. This is the TALYS output for Ne22+n.

5. mygoe.f input code which consists of TALYS parameters (Gg, D, S).

Entry  Sat Nov 4 14:01:18 2023, Selin Ezgi Birincioglu, Maxwellian Cross Section Distribution of Ca43+n macs1wrg.pdfmacs01wbin.pdfmacs11wbin.pdftalys.outCa44run

1. This graph is the Gaussian fitted Ca43+n with rebinned to 10 total. Theorotical cross section is around 110 while the experimental is 66.1.

2. This the the distribution of l = 0 with bins = 10.

3. This the the distribution of l = 1 with bins = 10.

4. This is the TALYS output for Ca43+n.

5. mygoe.f input code which consists of TALYS parameters (Gg, D, S).

Entry  Sat Nov 4 13:56:02 2023, Selin Ezgi Birincioglu, Maxwellian Cross Section Distribution of Ca42+n macs1wrg.pdfmacs01wbin.pdfmacs11wbin.pdftalys.outCa43run

1. This graph is the Gaussian fitted Ca42+n with rebinned to 10 total. Theorotical cross section is around 15 while the experimental is 16.5, which matches well.

2. This the the distribution of l = 0 with bins = 10.

3. This the the distribution of l = 1 with bins = 10.

4. This is the TALYS output for Ca42+n.

5. mygoe.f input code which consists of TALYS parameters (Gg, D, S).

Entry  Sat Nov 4 13:45:53 2023, Selin Ezgi Birincioglu, Maxwellian Cross Section Distribution of P31+n macs1wbg.pdfmacs01.pdfmacs11wbin.pdftalys.outP32run

1. This graph is fitted P31+n with rebinned to 10. Theorotical cross section is around 2 and the experimental value is 1.74, which relatively match.

2. This the the distribution of l = 0 with bins = 10.

3. This the the distribution of l = 1 with bins = 10.

4. This is the TALYS output for P31+n.

5. mygoe.f input code which consists of TALYS parameters (Gg, D, S).

Entry  Sat Nov 4 13:40:39 2023, Selin Ezgi Birincioglu, Maxwellian Cross Section Distribution of Si28+n macs1fit.pdfmacs01.pdfmacs11.pdftalys.outSi29run

1. This graph is the exponential decay Si28+n total. Theorotical cross section is between 0-1.5 while the experimental should be towards 1.15

2. This the the distribution of l = 0.

3. This the the distribution of l = 1.

4. This is the TALYS output for Si28+n.

5. mygoe.f input code which consists of TALYS parameters (Gg, D, S).

Entry  Sat Nov 4 13:18:53 2023, Selin Ezgi Birincioglu, Gaussian fit of Cl35+n with a binning of 10 macs1wrg.pdfmacs01wbin.pdfmacs11wbin.pdftalys.outCl36run

1. This graph is the Gaussian fitted Cl35+n with rebinned total. Experimental cross section is around 12 while the graph shows the maximum probability as around 7.

2. This the the distribution of l = 0 with bins = 10.

3. This the the distribution of l = 1 with bins = 10.

4. This is the TALYS output for Cl35+n.

5. mygoe.f input code which consists of TALYS parameters (Gg, D, S).

Entry  Wed Nov 1 16:14:37 2023, Selin Ezgi Birincioglu, Maxwellian Cross Section Distribution of Cl35+n macs1.pdfmacs01.pdfmacs11.pdf

Cross Section Distributions for Cl35+n; where macs01 is for l=0, macs11 is for l=1and macs1 is for the total. The most probable value is less than what is expected (around 13 in the EXCEL sheet).

Entry  Thu Oct 26 18:09:12 2023, Selin Ezgi Birincioglu, Maxwellian Cross Section Distribution of Na23+n macs1.pdfmacs01.pdfmacs11.pdf

Cross Section Distributions for Na23+n;where macs01 is for l=0, macs11 is for l=1and macs1 is for the total. This is an example of logarithmic decline due to high level spacing (stable nuclei).

Entry  Thu Oct 26 17:59:17 2023, Selin Ezgi Birincioglu, Maxwellian Cross Section Distribution of Cl37+n macs1.pdfmacs01.pdfmacs11.pdf

Cross Section Distributions for Cl37+n; where macs01 is for l=0, macs11 is for l=1 and macs1 is for the total. This is an example of Gaussian-like behaviour.

Entry  Wed Oct 18 15:54:26 2023, Selin Ezgi Birincioglu, Parameters from TALYS TALYSparameters.xlsx

These are the parameters taken from TALYS to further utilize them as inputs for MyGOE.f - generating nuclear levels. In the sheet the masses are target + n while the input mass is the target nuclei.