ID |
Date |
Author |
Subject |
Text |
 |
52
|
Fri Oct 27 17:13:58 2023 |
Emma Walker | Si-30: Dedicated vs Parasitic before and after removal of ambient | Below are histograms for the weighted spectra
(with deadtime correction) with and without
ambient for C6D6 detector 1. |
14x |
53
|
Mon Nov 6 11:13:11 2023 |
Emma Walker | Comparison of empty, ambient and sample- Si-30 | Below are graphs for each sample (weighted)
showing the comparison between ambient spectra,
empty/dummy holder and sample spectra. |
16x |
54
|
Tue Nov 7 13:21:51 2023 |
Emma Walker | Si-30: Comparison between background corrected and uncorrected | Below are graphs for the comparison between
background corrected and uncorrected spectra
(weighted) for Si-30, Au20, Au22 and Sinatgood. |
   |
1
|
Fri Nov 3 11:19:53 2017 |
Claudia | Sample Preparation | 77Se: m=0.9916 g; D= 20 mm
OLD: 77Se: m=0.919 g according
to ntofdaq page. D~ 20 mm NEEDS TO BE CONFIRMED |
  |
2
|
Fri Nov 3 11:22:43 2017 |
Claudia | Detector Configuration | Distance Sample to Detector: Det1: ~10.5
cm, Det2: 11 cm, Det3: 11 cm, Det4: 11 cm
|
  |
3
|
Fri Nov 3 15:06:51 2017 |
Claudia | Measurement Schedule updated | |
|
5
|
Fri Jul 3 14:01:38 2020 |
Claudia | Link to Ruchi's list of runs + description | https://docs.google.com/spreadsheets/d/1W1T2rC10UtOtrAaT8-ZAKFvX70v2PwDk_4-goYL-brI/edit?usp=sharing |
|
27
|
Tue Apr 11 14:07:43 2023 |
Claudia | Photos of the Zn68 measurement setup | Photos of the 68Zn(n,gamma) measuremement
setup at n_TOF EAR-1. |
    |
32
|
Thu Jul 13 14:19:37 2023 |
Claudia | dead time 30Si run | Default TTOFSort dead time setting of 30
ns is ok. |
|
35
|
Mon Jul 17 11:30:54 2023 |
Claudia | Properties Silicon powder samples | 30Si
Mass: 0.9925(1) g; Diameter:
22.22(1) mm; Thickness: 1.77(4) |
|
56
|
Wed Nov 15 13:40:50 2023 |
Claudia | Determination of neutron capture yield and related corrections | Here are all the files needed for calculation
of the yield. There is some information that
still needs to be added to the energyandyield.c |
   |
64
|
Thu Apr 4 09:50:36 2024 |
CLW | First Si analysis 2024 run | Au and Si29 runs normalised by proton number
show consistency (dedicated pulses, example
detector 4). Plots for tof spectra zooming |
6x |
66
|
Fri Jun 7 15:58:24 2024 |
CLW | ISOFLEX Certificates for enriched Si samples | Isoflex certificates for enriched silicon
samples |
 |
28
|
Thu Jun 15 09:57:01 2023 |
Annie | Si Set Up | Si Set up images and documentation.
Detector 1 - C6D6D: Distance= 9
cm, Angle= 135 deg relative to BL (check |
12x |
29
|
Thu Jun 22 10:37:39 2023 |
Annie | Gold 22mm Sample Images | New 22mm sample compared to old 20mm sample
used at the beginning of the campaign
+ picture of dummy target in the setup. |
  |
30
|
Thu Jun 29 09:21:13 2023 |
Annie | Info on Samples | Both Au samples (20mm and 22mm) are single
mylar.
Both Si30 (22mm) and natSi (20mm) are |
   |
43
|
Fri Aug 4 10:45:05 2023 |
Annie | Zn Plots: Normalised Spectra, Ratio Plots, Integral/Protons vs Cut (all dets) | All plots in the ratios all look pretty
contstant. Zn1 for all detectors seems to
have some strange spike in the integral, |
27x |
51
|
Tue Oct 24 11:29:46 2023 |
AR | Weighted Histograms Vs Deadtime*Corrected: 68Zn | |
24x |
55
|
Wed Nov 8 11:47:44 2023 |
AR | Zn68 TTOFSort codes | |
6x |
57
|
Thu Nov 30 14:43:28 2023 |
AR | Zn + Au Background subtraction: Plots | Plots for Zn and Au with Empty subtracted,
and compared to weighted spectra.
Note: Au are logged x and y, Zn |
21x |