22
Thu Aug 11 08:19:37 2016
Sarah
Leakage currents 10.8.16
At lunchtime (12.45)
E = 0.03 uA
dE = 0.04 uA
23
Wed Aug 17 15:10:05 2016
Sarah
Leakage currents 12.08.16
E = 0.03uA
dE = 0.04uA
PHDI = 0.06uA
25
Fri Sep 2 12:01:57 2016
Sarah
Leakage currents 02.09.16
E 0.03
dE 0.05
PHDI 0.12
26
Fri Sep 2 12:03:40 2016
Sarah
SPD card changed
14 bit card replaced for DEED 9-12, to
prevent issue with pulser arriving before
gamma flash.
27
Fri Sep 9 10:01:18 2016
Sarah
Leakage currents 09.09.16
EFED 0.04uA
DEED 0.05uA
PHDI 0.13uA
31
Thu Oct 6 11:07:47 2022
Nikolay Sosnin
Change of sample/Addition of pulser
Changed from LiF 4 to LiF 3 after running
with LiF 4 overnight (run title on n_TOF
DAQ was not updated to refelect the change,
32
Thu Oct 6 11:45:39 2022
Nikolay Sosnin
Assembly Setup Days 1 and 2
Photographs of assembly up to the first
pulser test with LiF3.
25x
33
Thu Oct 6 14:58:29 2022
Nikolay Sosnin
Change of Pulser Delay
Still using pulser triggered from protons.
12 microsecond delay from protons to gamma-flash
+ 1.75 microsecond delay from gamma flash
34
Fri Oct 7 17:17:08 2022
Nikolay Sosnin
Change of Pulser Delay
Still using pulser triggered from protons.
12 microsecond delay from protons to gamma-flash
+ 11 microsecond delay from gamma flash to
35
Fri Oct 7 20:04:30 2022
Nikolay Sosnin
Change of Pulser Setting
The pulser has been switched from triggering
from beam trigger to running at a 10 Hz rate,
and will now appear in random places in signal
36
Sat Oct 8 11:56:49 2022
Nikolay Sosnin
Silicon Strips of Concern
DEED 6 and 9 no signal throughout the campaign.
EFED 27 high oscillations in baseline
throughout the campaign.
37
Sat Oct 8 11:57:36 2022
Nikolay Sosnin
Change of Detector-Target Separation
Increased detector-target (LiF 3) separation
by 1.5 cm. Had to replace the support strut
under the detectors due to the previous one
17x
38
Sun Oct 9 20:57:54 2022
Nikolay Sosnin
Detectors in-beam, no target
After long beam-off, changed detector mount
by moving it 2 cm forward into the beam,
after removing LiF 3.
12x
40
Sun Oct 9 21:07:02 2022
Nikolay Sosnin
Boron Sample 3 Measurement
21:15 Changed from detectors in-beam to
boron-10 sample 3 in-beam (in-beam measurement
got 1000 triggers, 500 of which were dedicated).
14x
44
Mon Jul 31 10:21:41 2023
Nikolay Sosnin
n_TOF Data and Filtering
50
Thu Aug 10 10:50:15 2023
Nikolay Sosnin
Al26 Chamber Cabling/Vacuum/NIM
23x
51
Thu Aug 10 11:30:32 2023
Nikolay Sosnin
Silicons and LiF3+Gafchromic Target
18x
59
Fri Aug 11 13:16:56 2023
Nikolay Sosnin
E Front Incorrect Cabling
E front 2x16-way to 1x34-way IDC cable
from the Junction Box to the IDC-Lemo 00
adaptor was found to be inserted upside-down
60
Fri Aug 11 16:50:58 2023
Nikolay Sosnin
EDET24
After inserting aluminium target, previously-dead
channel 24 on EDET was re-plugged into a
12-bit card SPD02872. It is the only EDET
61
Sat Aug 12 09:24:19 2023
Nikolay Sosnin
26Al Protons
Here is a Google spreadsheet for counting
protons for the runs:
https://docs.google.com/spreadsheets/d/1INX8G9GAu-M70SdZdz55qXnMZNXKXLW7xfFH-eaLuQw/edit?usp=sharing