26
|
Fri Sep 2 12:03:40 2016 |
Sarah | SPD card changed | 14 bit card replaced for DEED 9-12, to
prevent issue with pulser arriving before
gamma flash. |
|
|
27
|
Fri Sep 9 10:01:18 2016 |
Sarah | Leakage currents 09.09.16 | EFED 0.04uA
DEED 0.05uA
PHDI 0.13uA |
|
|
31
|
Thu Oct 6 11:07:47 2022 |
Nikolay Sosnin | Change of sample/Addition of pulser | Changed from LiF 4 to LiF 3 after running
with LiF 4 overnight (run title on n_TOF
DAQ was not updated to refelect the change, |
|
|
32
|
Thu Oct 6 11:45:39 2022 |
Nikolay Sosnin | Assembly Setup Days 1 and 2 | Photographs of assembly up to the first
pulser test with LiF3. |
25x |
|
33
|
Thu Oct 6 14:58:29 2022 |
Nikolay Sosnin | Change of Pulser Delay | Still using pulser triggered from protons.
12 microsecond delay from protons to gamma-flash
+ 1.75 microsecond delay from gamma flash |
|
|
34
|
Fri Oct 7 17:17:08 2022 |
Nikolay Sosnin | Change of Pulser Delay | Still using pulser triggered from protons.
12 microsecond delay from protons to gamma-flash
+ 11 microsecond delay from gamma flash to |
|
|
35
|
Fri Oct 7 20:04:30 2022 |
Nikolay Sosnin | Change of Pulser Setting | The pulser has been switched from triggering
from beam trigger to running at a 10 Hz rate,
and will now appear in random places in signal |
|
|
36
|
Sat Oct 8 11:56:49 2022 |
Nikolay Sosnin | Silicon Strips of Concern | DEED 6 and 9 no signal throughout the campaign.
EFED 27 high oscillations in baseline
throughout the campaign. |
|
|
37
|
Sat Oct 8 11:57:36 2022 |
Nikolay Sosnin | Change of Detector-Target Separation | Increased detector-target (LiF 3) separation
by 1.5 cm. Had to replace the support strut
under the detectors due to the previous one |
17x |
|
38
|
Sun Oct 9 20:57:54 2022 |
Nikolay Sosnin | Detectors in-beam, no target | After long beam-off, changed detector mount
by moving it 2 cm forward into the beam,
after removing LiF 3. |
12x |
|
40
|
Sun Oct 9 21:07:02 2022 |
Nikolay Sosnin | Boron Sample 3 Measurement | 21:15 Changed from detectors in-beam to
boron-10 sample 3 in-beam (in-beam measurement
got 1000 triggers, 500 of which were dedicated). |
14x |
|
44
|
Mon Jul 31 10:21:41 2023 |
Nikolay Sosnin | n_TOF Data and Filtering | |
|
|
50
|
Thu Aug 10 10:50:15 2023 |
Nikolay Sosnin | Al26 Chamber Cabling/Vacuum/NIM | |
23x |
|
51
|
Thu Aug 10 11:30:32 2023 |
Nikolay Sosnin | Silicons and LiF3+Gafchromic Target | |
18x |
|
59
|
Fri Aug 11 13:16:56 2023 |
Nikolay Sosnin | E Front Incorrect Cabling | E front 2x16-way to 1x34-way IDC cable
from the Junction Box to the IDC-Lemo 00
adaptor was found to be inserted upside-down |
|
|
60
|
Fri Aug 11 16:50:58 2023 |
Nikolay Sosnin | EDET24 | After inserting aluminium target, previously-dead
channel 24 on EDET was re-plugged into a
12-bit card SPD02872. It is the only EDET |
 |
|
61
|
Sat Aug 12 09:24:19 2023 |
Nikolay Sosnin | 26Al Protons | Here is a Google spreadsheet for counting
protons for the runs:
https://docs.google.com/spreadsheets/d/1INX8G9GAu-M70SdZdz55qXnMZNXKXLW7xfFH-eaLuQw/edit?usp=sharing |
|
|
65
|
Thu Aug 17 10:26:51 2023 |
Nikolay Sosnin | Data Processing | To run raw2root on LXPLUS, you will need
to add the following line to your .bashrc,
performed using |
|
|
28
|
Thu May 26 09:20:32 2022 |
Nick / Claudia | Inventory of Items at n_TOF for (n,cp) experiments | Detectors currently in the boxes:
2x MSL type W1(SS)-50, 2902-4 (53um),
2940-6 (55um) |
 |
|
76
|
Thu Sep 12 11:07:29 2024 |
Nick | 40K Borrowed Items | We borrowed from n_TOF:
1x O-ring for circular side-flanges
on the chamber (the borrowed part has a small |
|