88
|
Sat Jul 12 11:34:31 2025 |
Selin | Detector-Cable Connections | List of the detectors and the connections. |
|
|
46
|
Thu Aug 10 09:20:37 2023 |
CLW | Detector Signal Cabling Al26 Aug 2023 |
delta
E detector Cabling
|
8x |
|
45
|
Thu Aug 10 09:10:02 2023 |
CLW | Detector Setup Al26 Run 2023 | dE Detector: W1-20 3186-9 20 um
E Detector: W1-150 3458-4 144 um
Voltages and Leakage Currents: |
   |
|
65
|
Thu Aug 17 10:26:51 2023 |
Nikolay Sosnin | Data Processing | To run raw2root on LXPLUS, you will need
to add the following line to your .bashrc,
performed using |
|
|
15
|
Sun Jul 31 15:02:57 2016 |
Sarah | DEED6 Alpha calibration checks (205168) | DEED6: (1 bin = 2 ch)
|
|
|
16
|
Sun Jul 31 15:56:32 2016 |
Sarah | DEED16 Alpha calibration checks (205169) | ***note that DEED 16 was on old sampling
rate for 205168- so use next run, also DEED
9-12 not plugged in*** |
|
|
14
|
Sun Jul 31 14:32:34 2016 |
Sarah | DEED1 Alpha calibration checks (205168) | DEED1: (rebin x2 -> 1 bin = 4
ch)
Pulser (DAQ): |
|
|
100
|
Mon Aug 18 09:19:27 2025 |
Emmanuel | DEED 11 NO Gamma Flash Signal | We observed that DEED11 no longer have
Gamma flash signals.
Before the drop, it had some weird |
    |
|
101
|
Thu Aug 21 16:19:43 2025 |
Emmanuel | Checking DEED 11 with the Pulser | We checked DEED 11 with the Pulser and
it was still unresponsive (See screenshot).
Next, we will change the LEMO cables |
|
|
31
|
Thu Oct 6 11:07:47 2022 |
Nikolay Sosnin | Change of sample/Addition of pulser | Changed from LiF 4 to LiF 3 after running
with LiF 4 overnight (run title on n_TOF
DAQ was not updated to refelect the change, |
|
|
35
|
Fri Oct 7 20:04:30 2022 |
Nikolay Sosnin | Change of Pulser Setting | The pulser has been switched from triggering
from beam trigger to running at a 10 Hz rate,
and will now appear in random places in signal |
|
|
33
|
Thu Oct 6 14:58:29 2022 |
Nikolay Sosnin | Change of Pulser Delay | Still using pulser triggered from protons.
12 microsecond delay from protons to gamma-flash
+ 1.75 microsecond delay from gamma flash |
|
|
34
|
Fri Oct 7 17:17:08 2022 |
Nikolay Sosnin | Change of Pulser Delay | Still using pulser triggered from protons.
12 microsecond delay from protons to gamma-flash
+ 11 microsecond delay from gamma flash to |
|
|
37
|
Sat Oct 8 11:57:36 2022 |
Nikolay Sosnin | Change of Detector-Target Separation | Increased detector-target (LiF 3) separation
by 1.5 cm. Had to replace the support strut
under the detectors due to the previous one |
17x |
|
41
|
Mon Jul 3 13:01:30 2023 |
Emmanuel | Boxes for nTOF experiments to CERN | Box 1
1. RC412 Cables
2. Screws and parts for rails |
|
|
98
|
Mon Aug 4 16:45:43 2025 |
Selin | Boron-3 Consistency Check | These are the consistency checks done for
Boron-3 sample.
Please note that the back strips |
   |
|
97
|
Mon Aug 4 16:44:06 2025 |
Selin | Boron-1 Consistency Check | These are the consistency checks done for
Boron-1 sample. |
   |
|
92
|
Wed Jul 16 11:45:39 2025 |
Selin | Boron Spectra Update After Setting Change + Pulser Removed | Uncalibrated amplitude spectra of Boron
(run221188) after the settings were changed,
the pulser was removed, and the threshold |
 |
|
40
|
Sun Oct 9 21:07:02 2022 |
Nikolay Sosnin | Boron Sample 3 Measurement | 21:15 Changed from detectors in-beam to
boron-10 sample 3 in-beam (in-beam measurement
got 1000 triggers, 500 of which were dedicated). |
14x |
|
82
|
Tue Mar 18 13:28:30 2025 |
Emmanuel | B10 and LiF data with Fast Fourier Transform | Attached is the B10 and LiF data with
Fast Fourier Transform and varying time
constants. |
 |