Entry  Thu Oct 6 14:58:29 2022, Nikolay Sosnin, Change of Pulser Delay 
Still using pulser triggered from protons. 12 microsecond delay from protons to gamma-flash + 1.75 microsecond delay from gamma flash to pulser. 20 mV
pulser output into 50 ohm impedance (10 mV final output) of both polarities (using two pulsers, one NE pulser and one BNC PB5 pulser). Changed pulser setting
to run with 5 microsecond delay for approx. 1 hour, then change to 10 microsecond delay.
Entry  Thu Oct 6 11:45:39 2022, Nikolay Sosnin, Assembly Setup Days 1 and 2 25x
Photographs of assembly up to the first pulser test with LiF3.
Entry  Thu Oct 6 11:07:47 2022, Nikolay Sosnin, Change of sample/Addition of pulser 
Changed from LiF 4 to LiF 3 after running with LiF 4 overnight (run title on n_TOF DAQ was not updated to refelect the change, and still says LiF 4,
but the material setting of the run states correctly that hte run is with LiF 3).

Added pulser triggered from protons. 12 microsecond delay from protons to gamma-flash + 1.75 microsecond delay from gamma flash to pulser. 20
Entry  Thu Oct 6 09:34:30 2022, Claudia, Test setup Photos and cabling 20221005_174742.jpg20221005_174759.jpg20221005_184752.jpg20221005_184801.jpg20221005_174742.jpg
Setup 5.10.22

dE 20 um (ID 2837-33) and 494 um double sided (ID 1194-9)

46 channels (2 connectors missing)
Entry  Thu Oct 6 09:28:33 2022, Claudia, Items to be replaced for next run 20221005_122654.pdf
Missing/broken items identified

- long rails for fixing chamber on support

- vacuum valve (ours is broken)
Entry  Thu May 26 09:20:32 2022, Nick / Claudia, Inventory of Items at n_TOF for (n,cp) experiments rn_image_picker_lib_temp_e85b2099-7b73-4246-843d-6351800c2709.jpgrn_image_picker_lib_temp_3ff5f819-1e0c-4278-bbbc-01038a0a0c94.jpg
Detectors currently in the boxes:

2x MSL type W1(SS)-50, 2902-4 (53um), 2940-6 (55um)

1x MSL type W1(SS)-20 2837-33 (20um)
Entry  Fri Sep 9 10:01:18 2016, Sarah, Leakage currents 09.09.16 
EFED 0.04uA
DEED 0.05uA
PHDI 0.13uA
Entry  Fri Sep 2 12:03:40 2016, Sarah, SPD card changed 
14 bit card replaced for DEED 9-12, to prevent issue with pulser arriving before gamma flash.
Entry  Fri Sep 2 12:01:57 2016, Sarah, Leakage currents 02.09.16 
E 0.03
dE 0.05
PHDI 0.12
Entry  Tue Aug 23 15:34:38 2016, Claudia, Leakage currents 23.08.16 
 E = 0.03uA
dE = 0.04uA
PHDI = 0.09uA
Entry  Wed Aug 17 15:10:05 2016, Sarah, Leakage currents 12.08.16 
 E = 0.03uA
dE = 0.04uA
PHDI = 0.06uA
Entry  Thu Aug 11 08:19:37 2016, Sarah, Leakage currents 10.8.16 
 At lunchtime (12.45)
E = 0.03 uA
dE  = 0.04 uA
Entry  Tue Aug 9 15:57:52 2016, Sarah, Leakage currents 09.08.16 
 Morning - 9am
E= 0.03uA
dE= 0.04uA
Entry  Mon Aug 8 11:02:13 2016, Sarah, Leakage currents 08.08.16 
 E 0.03 uA
dE 0.04 uA
PHDI 0.05 uA
Entry  Wed Aug 3 14:48:09 2016, Sarah, Leakage currents 02.08 - 03.08 
 02.08:
dE = 0.03 uA
E = 0.03 uA
Entry  Wed Aug 3 09:48:31 2016, Sarah, EFED10 alpha calibration checks 
 

    
        

           
Entry  Tue Aug 2 08:14:26 2016, Sarah, Leakage currents spreadsheet (26/07- 01/08) Leakage_currents.xlsx
 Steady for dE, E. Possibly rising on PHDI- monitor closely.
Entry  Sun Jul 31 15:56:32 2016, Sarah, DEED16 Alpha calibration checks (205169) 
***note that DEED 16 was on old sampling rate for 205168- so use next run, also DEED 9-12 not plugged in***

Entry  Sun Jul 31 15:02:57 2016, Sarah, DEED6 Alpha calibration checks (205168) 
 DEED6: (1 bin = 2 ch)
Pulser (DAQ):
- Centroid = 5145.6(6) ch
Entry  Sun Jul 31 14:32:34 2016, Sarah, DEED1 Alpha calibration checks (205168) 
 DEED1: (rebin x2 -> 1 bin = 4 ch)
Pulser (DAQ):
- Centroid = 5000(1) ch