Entry  Mon Apr 25 10:11:40 2016, CG, KM, PV & TD, Monday 25 April 

AIDA stand, Julabo FL11006 recirculating chiller (with 110VAC/50Hz - 240VAC/50Hz 3ph transformer)
moved from F11 downstream wall to ~2m downstream of EURICA
Entry  Mon Apr 25 08:58:25 2016, TD, Report - high? - aidas1 - Binding NIS service FAILED  messages
During a reboot of aidas1 the message 

Binding NIS service FAILED
Entry  Thu Apr 14 13:56:17 2016, PJCS, Updating the FEE64 firmware. FEE_GF_Feb16_15.bin
To update the FEE64 firmware:-

    Power-up the FEE64 modules that you wish to update.
    Identify the file to be used ( FEE_GF_Feb16_15.bin  at 14/4/2016
)
    This file should be in the Server ( e.g. aidas1 ) at /MIDAS/Aida.
    Edit the file /MIDAS/Aida/FlashPgm.csh and change the file
Entry  Tue Mar 22 10:59:52 2016, TD : PJCS, Tuesday 22 March 7x
MSL type BB18(DS)-1000 serial 2998-22
Bias +200V, I_L +=5.515uA, ambient temperature +19.8 deg C
 
Entry  Mon Mar 21 14:37:41 2016, PJCS, Vernier Timing document for comment Considering_the_Vernier_Timing_unit_in_the_FEE64.pdf
Here is a document about the FEE64 waveform Vernier Timing.
Please comment/criticise/offer advice.
 
Entry  Thu Mar 17 10:46:30 2016, TD, Analysis of R45 8x
See https://elog.ph.ed.ac.uk/AIDA/179

207Bi source, no pulser
Entry  Tue Mar 15 11:15:42 2016, TD, Tuesday 15 March 10.png11.png12.png13.png14.png
MSL type BB18(DS)-1000 serial 2998-22
Bias +200V, I_L +=5.845uA, ambient temperature +19.8 deg C
 
Entry  Mon Mar 14 11:27:47 2016, PJCS, ASIC_clock synchronisation across the system R44_0.zip.zip
During 'SETUP' the ASIC readout clock ( 500KHz ) is synchronised to the SYNC pulse in V8.10 and later versions of the VHDL.
Attached is a short run for verification.
 
Entry  Fri Mar 11 15:31:53 2016, TD, Analysis of R34_0 1.png2632.txt2.png3.png4.png
lancre> ./analyser R34_0
 *** GREAT format 3.2.0 analyser - TD - May 2014
 *** ERROR: READ I/O error:       5002
Entry  Tue Mar 8 16:29:07 2016, TD, Report - high - AIDA timestamps 8.png
Version 8 firmware

Analysing R37_* data files (see https://elog.ph.ed.ac.uk/AIDA/160)
    Reply  Thu Mar 10 16:35:39 2016, TD : PJCS, Report - high - AIDA timestamps Time_Difference_FEE13to14.png
> Version 8 firmware

> Analysing R37_* data files (see https://elog.ph.ed.ac.uk/AIDA/160)
Entry  Tue Mar 8 15:09:49 2016, TD, Report - high - LEC/MEC fast comparator issues 6x

Fast comparator rate spectra and statistics do not appear to working as expected. See enclosed screenshots.
Have the hit/rate spectra and statistics been updated to reflect the firmware version 8 data format?
    Reply  Wed Mar 9 17:31:58 2016, TD, Report - high - LEC/MEC fast comparator issues Discriminator_Thresh_50

> Fast comparator rate spectra and statistics do not appear to working as expected. See enclosed screenshots.
> Have the hit/rate spectra and statistics been updated to reflect the firmware version 8 data format?
Entry  Wed Mar 9 16:18:01 2016, TD, nndhcp021 AIDA server Httpd/TapeServer/Merger startup 
Starting Httpd for the TapeServer/Merger, TapeServer and Merger for AIDA produces
three terminal windows which will display the following text messages
Entry  Wed Mar 9 12:16:01 2016, TD, Wednesday 9 March 
MSL type BB18(DS)-1000 serial 2998-22
Bias +200V, I_L +=6.505uA, ambient temperature +19.8 deg C
 
Entry  Tue Mar 8 15:40:57 2016, TD, Tuesday 8 March 
MSL type BB18(DS)-1000 serial 2998-22
Bias +200V, I_L +=6.705uA, ambient temperature +19.8 deg C
 
Entry  Tue Mar 8 15:32:53 2016, TD, Report - low - run control frame issue with multiple streams 7.png
The run control frame does not appear to update the data transfer 'X' tag 
for all FEE modules after selecting 'Enable #1 All'
Entry  Tue Mar 8 06:00:45 2016, CG, AE, RIKEN maintenance progress 2016-03-07_15.54.46.jpg
 07/03/16
The new snout doesn't fit due to the screw holes being misaligned. I am going to try modifying the old one (that was in conflict with some material
in the base) over the next couple of days. It is too long by 11mm, so if I can remove that it should then fit..
    Reply  Tue Mar 8 12:11:56 2016, CG, AE, RIKEN maintenance progress 


    
        
            Quote:
        
        
            

            07/03/16
Entry  Wed Feb 24 14:53:41 2016, PJCS, First data with two streams merged from one FEE64 R1_0.gz
nnaida2 running Version 8 Firmware and data acquisition software outputting both and ASIC data stream and a Waveform data stream to the Merge process.
Merged data is written to file ... attached.
The waveform is running at 100Hz and ASIC data is running at 10Hz.
    Reply  Wed Feb 24 16:13:24 2016, PJCS, First data with two streams merged from one FEE64 


    
        
            Quote:
        
        
            

           nnaida2 running Version 8 Firmware and data acquisition software outputting both and ASIC data stream and a Waveform data stream to the Merge
    Reply  Thu Feb 25 12:47:43 2016, PJCS, First data with two streams merged from one FEE64 analyser.f

My GREAT data analyser program reports that the 'fail' bit is set ?
       Reply  Wed Mar 2 11:59:48 2016, PJCS, First data with two streams merged from one FEE64 
The Fail bit is used to indicate The Timing Vernier  word.
I'll post a seperate Elog entry to explain the format.
Entry  Wed Feb 24 15:46:11 2016, PJCS, OR64 - OR of all the ASIC discriminator channels after application of a mask IMG_0290.JPG
Firmware version8 number 8 has an OR64 added which can be routed, using the Local control, to the Trigger output and hence seen at the front panel Fast
NIM LEMO00 connector.
The OR64 is the OR of all the ASIC Discriminators. Each rising edge of a discriminator signal will give a 10ns pulse on the Fast NIM signal. If
Entry  Wed Feb 24 13:54:53 2016, TD, Report - low - FEE temperature plot displays incorrect dates 77.png

See Attachment 1
Entry  Wed Feb 24 10:25:35 2016, TD, Wednesday 24 February 2016 78.png79.png80.png81.png
MSL type BB18(DS)-1000 serial 2998-22
Bias +200V, I_L +=5.770uA, ambient temperature +19.8 deg C
 