Thu Nov 22 07:01:36 2018, AT, PID high mass seting (165Pm) - RIBF148
|
PID plot for the high mass setting (165Pm), run 2018, rare earth peak experiment.
Partial statistics (~30h) from identification at F7.
Please use for internal reports about the BRIKEN activities. |
Tue Nov 6 21:51:54 2018, NT Brewer, New D4Off.conf for HV also on github
|
V A V/s V/s 1/0
------ ---------------
--------- ----- ---- ------- ------- ------ ------ -------------
0
192.168.13.239 0 0 PA1 1450 0.0001 50 10 1
0 192.168.13.239 1 |
Mon Nov 5 22:47:40 2018, AT, JR, FM, PA, Low threshold, 252Cf, z=0cm, perpendicular 0 deg
|
252Cf at z=0cm, i.e 0 cm from the center of the detector, source axis perpendicular at 0 deg
Low threshold.
|
Mon Nov 5 21:24:20 2018, AT, JR, FM, PA, Low threshold, 252Cf, z=25cm, perpendicular 90 deg
|
252Cf at z=25cm, i.e 25 cm from the center of the detector, source axis perpendicular at 90 deg
Low threshold.
|
Mon Nov 5 19:55:20 2018, AT, JR, FM, PA, Low threshold, 252Cf, z=0cm, perpendicular 90 deg
|
252Cf at z=0cm, i.e 0 cm from the center of the detector, source axis perpendicular at 90 deg
Low threshold.
|
Mon Nov 5 09:59:36 2018, MW, KR, suspicious clover G7 temp sensor
|
We observed 6 pm LN2 filling of both clovers on Monday Nov 5th.
D4 went full within reasonable time of below 10 minutes.
Filling of G7 was stopped by "emergency sensor" after about 15 minutes of filling. |
Mon Nov 5 18:52:54 2018, MW, KR, suspicious clover G7 temp sensor
|
Quote:
We observed 6 pm LN2 filling of both clovers on Monday Nov 5th. |
Mon Nov 5 18:05:48 2018, AT, JR, FM, PA, Low threshold, 252Cf, z=25cm, perpendicular 0 deg
|
252Cf at z=25cm, i.e 25 cm from the center of the detector, source axis perpendicular
Low threshold.
|
Mon Nov 5 16:43:43 2018, FM, PA,, Low threshold, 252Cf, z=25cm, Parallel downstream
|
252Cf at z=25cm, i.e 25 cm from the center of the detector, source axis parallel downstream
Low threshold.
|
Mon Nov 5 15:10:43 2018, FM, PA,, Low threshold, 252Cf, z=15cm, Parallel downstream
|
252Cf at z=15cm, i.e 15 cm from the center of the detector, source axis parallel downstream
Low threshold.
|
Mon Nov 5 13:43:57 2018, FM, PA, Low threshold, 252Cf, z=0cm, Parallel downstream
|
252Cf at z=0cm,ie center of moderator, source axis parallel downstream
Low threshold.
|
Mon Nov 5 12:04:08 2018, FM, PA, AT, Low threshold, 252Cf, z=15cm, Perpendicular 0deg
|
252Cf at z=15cm,ie center of moderator, source axis perpendicular at 0deg (typical orientation)
Low threshold.
|
Mon Nov 5 09:32:00 2018, FM, JR, PA, AT, Low threshold, 252Cf, z=0cm, Perpendicular 0deg
|
252Cf at z=0cm,ie center of moderator, source axis perpendicular at 0deg (typical orientation)
Low threshold.
|
Mon Nov 5 06:46:30 2018, KR, YR, MW, JLT, ..., Clover check
|
With detectors still on the floor we check signals and found
that D4 gives no signal with PA power. Two power supplies/cables were checked.
|
Fri Nov 2 14:18:54 2018, JLT, 136Sn at ZDS
|
Measurement of neutron background while
Jungclaus experiment is running
Secondary beam 136Sn at ~140MeV/u, Be target, 136Sn in the ZDS
|
Fri Nov 2 01:07:21 2018, JLT, 134Sn/133In on ZDS
|
Measurement of neutron background while
Jungclaus experiment is running
Secondary beam:
|
Wed Oct 31 03:41:33 2018, JLT, 134Sn at ZDS
|
Measurement of neutron background while
Jungclaus experiment is running
Secondary beam 134Sn at ~140MeV/u, Au target, 134Sn in the ZDS
|
Wed Oct 31 00:36:34 2018, JLT, 133In at ZDS
|
Measurement of neutron background while
Jungclaus experiment is running
Secondary beam 134Sn at XXMeV, Be target, 133In i the ZDS
|
Tue Oct 30 01:01:42 2018, JLT, AA, Adjustment of 3He thresholds
|
Background with BigRIPS+ZD already working
No pulser
|
Mon Oct 29 12:08:12 2018, JR, JA, AT, Background
|
Background was measurement
Pulser: NO
|
Sun Oct 28 07:41:03 2018, AT, JA, AA, Background
|
Dacq was reinitialized
Background was measurement
Pulser: YES
|
|