Entry  Sat Oct 21 07:26:13 2017, NB, RY, BD, MS, Corrected Calibration D4 D4Oct19.ods
 	K		R		G		B
m	0.001558636	0.0006599344	0.0015311753	0.0015807021
b	-0.6545742444	0.4330534066	2.001278013	1.0994163913
				
				
FWHM are <= 3 keV @ 1408				
K		R		G		B	
3.1458290692	2.5879235958	2.9829238667	3.0707781948	
 				
The green leaf of D4 may have a noticeable non-linearity above 1MeV.				
Entry  Sat Nov 26 16:54:17 2016, AT & AT, Clovers 
Calibration of clovers
Entry  Thu May 25 13:38:11 2017, AT, PC, KR, JLT, AA, Clover, detectors in new position CLOVER-sketch.jpgD4-insertion.jpgG7-insertion.jpg
Both clover detectors were moved. They are in a symmetrical position. The end on the clover nose is of the order
of 3-4 mm from the AIDA tunnel.

See sketch of CLOVERS with respect to beam.

See photos of the insertion distance of
both CLOVERS
Entry  Thu May 25 12:53:47 2017, AT, PC, JLT, KR, AA, Clover, 60Co 
60Co source 

Source ID: CD395
same type as 133Ba source


Start: 20:57
Stop:21:18


Position: z=0 cm, No AIDA
Pulser connected

There was an small file (dlt) before this run with no pulser connected (170525_2054_60Co_z0cm_004.dlt), 
that run for only 3-4 min.

Files
170525_2057_60Co_z0cm_005.dlt
170525_2057_2118_60Co_z0cm_pulser.root

Comment: we noticed that the two clovers had different statistics for the 1332 peak. To be checked why
(source not in place ?)
The pulser shows similar counts, so the reason can not be deadtime

Answer: the D4 was not in its right position !!!!, efficiency calibrations have to be repeated :-(
Entry  Thu May 25 12:49:55 2017, AT, JLT,PC,AA, Clover, 133Ba, LN2 filling 
We started the measurement of the source when the N2 filling started. Just to  check if there are funny things
related to the filling.

Start: 18:45
Stop: 20:48

The source was in position z=0 cmm (no AIDA) 

File name: 170525_1845_2048_133Ba_NFilling_z0cm_noD4Pulser.root
Entry  Sun Oct 22 08:52:17 2017, KR,JA,ATD,JLT, Clover resolution 
Resolution check using 40K 1460 keV line 
in the background measurement overnight
(File: 171022_0126_1101_bck.root)

D4: 2.9 1keV @ 1461.8 keV
G7: 2.98 keV @ 1460.0 keV
Entry  Mon Nov 5 06:46:30 2018, KR, YR, MW, JLT, ..., Clover check Screenshot_from_2018-11-05_15-57-40.pngScreenshot_from_2018-11-05_16-23-12.png
With detectors still on the floor we check signals and found
that D4 gives no signal with PA power.  Two power supplies/cables were checked.
The detector was still working just before Jungclaus experiment. In July it was working.

Temperature monitors OK: 76-80 units

We mount both CLovers in position and make all connections.


We apply HV and check the resolution of G7.

Source: 152Eu
File: 181105_1550_CloverCheck_152Eu.root

As can be  seen in the attached figure the calibration used last year
is still pretty good

Resolution @ 1408 keV

G7 black: 2.75keV
  NO.   NAME      VALUE            ERROR          SIZE      DERIVATIVE 
   1  Constant     6.57807e+02   1.35347e+01   4.63240e-02  -7.68897e-07
   2  Mean         1.40766e+03   1.96681e-02   6.71225e-04   5.14533e-03
   3  Sigma        1.16983e+00   1.52231e-02   1.41407e-05  -1.28285e-02

G7  red: 2.97keV
  NO.   NAME      VALUE            ERROR          SIZE      DERIVATIVE 
   1  Constant     5.60626e+02   1.17448e+01   3.69357e-02   1.06287e-06
   2  Mean         1.40659e+03   2.29862e-02   6.70713e-04   1.36869e-04
   3  Sigma        1.26305e+00   1.62145e-02   1.30239e-05  -1.44151e-02

G7 green: 2.75keV
  NO.   NAME      VALUE            ERROR          SIZE      DERIVATIVE 
   1  Constant     7.87830e+02   1.48889e+01   3.68407e-02   5.57077e-06
   2  Mean         1.40597e+03   1.75988e-02   6.70417e-04  -2.47334e-03
   3  Sigma        1.17167e+00   1.41220e-02   9.59214e-06   1.55873e-02

G7 blue: 2.73keV
  NO.   NAME      VALUE            ERROR          SIZE      DERIVATIVE 
   1  Constant     4.99089e+02   1.19364e+01  -6.77351e-03  -4.15987e-06
   2  Mean         1.40489e+03   2.17210e-02   2.57134e-05   2.38923e-03
   3  Sigma        1.16057e+00   1.73778e-02   3.14777e-06   2.01018e-02


FWHM:
Entry  Wed Oct 18 08:46:23 2017, NB, SG, AT, JL, Clover G7 resolution 171018_1627_152Eu_G7.root
G7 clover was on the stand
Source: 152Eu
File: 171018_1627_152Eu_G7.root

Resolution check for 1408 keV peak

         FWHM(keV)  Mean (keV)
G7Black    2.88     1407.2
G7 Red     3.06     1406.8
G7 Green   2.81     1407.0
G7 Blue    2.93     1406.5
Entry  Mon May 29 04:17:34 2017, YS, Clover Efficiency eff_crystal.pdfeff_total.pdfEURICA_efficiency.jpg
Clover gamma detection efficiency calculation with 152Eu
Date of the measurement: 2017-05-26 10:15
root file: 170526_1015_152Eu_noAIDA_z0cm_014.root

Gamma Energy[keV] {121.781700, 244.697500, 344.278500, 444.000000, 778.904500, 867.378000, 964.100000,
1112.074000, 1408.011000}

Crystal ID 152 Efficiency[%]  {1.536508, 0.978779, 0.736707, 0.591553, 0.359426, 0.338228, 0.300229, 0.272331,
0.220314}
Crystal ID 152 Efficiency Error  {0.030465, 0.021204, 0.014732, 0.016358, 0.008284, 0.011340, 0.006673,
0.006173, 0.004757}

Crystal ID 153 Efficiency[%]  {1.679147, 1.051609, 0.799702, 0.628184, 0.386672, 0.387489, 0.328493, 0.300337,
0.236573}
Crystal ID 153 Efficiency Error  {0.033341, 0.023338, 0.016004, 0.017827, 0.008906, 0.013626, 0.007298,
0.006773, 0.005071}

Crystal ID 154 Efficiency[%]  {1.402847, 0.922081, 0.696455, 0.593818, 0.348820, 0.341118, 0.298197, 0.276055,
0.215494}
Crystal ID 154 Efficiency Error  {0.027933, 0.020478, 0.014004, 0.017865, 0.008087, 0.012283, 0.006708,
0.006288, 0.004660}

Crystal ID 155 Efficiency[%]  {1.329735, 0.886053, 0.665180, 0.559708, 0.340513, 0.340755, 0.288800, 0.261229,
0.202480}
Crystal ID 155 Efficiency Error  {0.026511, 0.020274, 0.013378, 0.016628, 0.007732, 0.010686, 0.006432,
0.005958, 0.004413}

Crystal ID 156 Efficiency[%]  {1.163705, 0.757446, 0.548990, 0.465020, 0.282777, 0.294110, 0.237165, 0.220572,
0.155430}
Crystal ID 156 Efficiency Error  {0.023277, 0.017832, 0.011114, 0.014924, 0.006765, 0.010733, 0.005496,
0.005160, 0.003514}

Crystal ID 157 Efficiency[%]  {1.420320, 0.906654, 0.672645, 0.536032, 0.347827, 0.346548, 0.298879, 0.269536,
0.196238}
Crystal ID 157 Efficiency Error  {0.028367, 0.020536, 0.013537, 0.016528, 0.008115, 0.012147, 0.006664,
0.006128, 0.004314}

Crystal ID 158 Efficiency[%]  {1.271836, 0.790926, 0.591132, 0.494340, 0.311442, 0.295866, 0.255764, 0.227822,
0.168103}
Crystal ID 158 Efficiency Error  {0.025589, 0.018723, 0.011955, 0.015706, 0.007457, 0.010690, 0.005849,
0.005296, 0.003762}

Crystal ID 159 Efficiency[%]  {1.268501, 0.806356, 0.588627, 0.511611, 0.297958, 0.326487, 0.252316, 0.231872,
0.175679}
Crystal ID 159 Efficiency Error  {0.025339, 0.018906, 0.011939, 0.016912, 0.007159, 0.011892, 0.005740,
0.005411, 0.003900}

Total Efficiency[%]  {11.072600, 7.099903, 5.299439, 4.380266, 2.675436, 2.670601, 2.259844, 2.059754, 1.570310}
Total Efficiency Error  {0.078525, 0.057205, 0.037954, 0.047007, 0.022172, 0.033133, 0.018054, 0.016749, 0.012242}

Fitting Function: 10^{p_0 + p_1*ln(x) + p_2*ln^2(x) + p_3/x^2} (This is the function used in the textbook
"Radiation detection and measurement" by G.Knoll)

Parameters
Total (two clovers): 
p_0 = 2.29172e-01 +/- 1.13185e-02
p_1 = 9.48436e-01 +/- 8.89344e-04
p_2 = -1.54934e-01 +/- 7.58240e-05
p_3 = 1.89920e+06 +/- 1.18292e+09


ID152:
 FCN=1.11317 FROM HESSE     STATUS=NOT POSDEF     23 CALLS         325 TOTAL
                     EDM=1.40411e-09    STRATEGY= 1      ERR MATRIX NOT POS-DEF
  EXT PARAMETER                APPROXIMATE        STEP         FIRST
  NO.   NAME      VALUE            ERROR          SIZE      DERIVATIVE
   1  p0           8.09248e+00   4.00474e-02   1.92940e-06   7.13568e-03
   2  p1          -2.02411e+00   8.19548e-03   4.82585e-07   4.27674e-02
   3  p2           9.78402e-02   1.18086e-03   2.33269e-08   2.59077e-01
   4  p3          -2.11550e+09   1.97563e+08   5.04375e+02   2.35344e-13

ID153:
 FCN=7.1582 FROM HESSE     STATUS=NOT POSDEF     23 CALLS         345 TOTAL
                     EDM=1.28369e-11    STRATEGY= 1      ERR MATRIX NOT POS-DEF
  EXT PARAMETER                APPROXIMATE        STEP         FIRST
  NO.   NAME      VALUE            ERROR          SIZE      DERIVATIVE
   1  p0           5.98204e+00   4.02864e-02   1.42623e-06   1.27251e-03
   2  p1          -1.30120e+00   8.24403e-03   3.10231e-07   7.00775e-03
   3  p2           3.70097e-02   1.18706e-03   2.80719e-08   3.85335e-02
   4  p3          -1.43256e+09   1.97976e+08   3.41550e+02   1.75334e-14

ID154:
 FCN=7.31777 FROM HESSE     STATUS=NOT POSDEF     23 CALLS         300 TOTAL
                     EDM=7.25203e-09    STRATEGY= 1      ERR MATRIX NOT POS-DEF
  EXT PARAMETER                APPROXIMATE        STEP         FIRST
  NO.   NAME      VALUE            ERROR          SIZE      DERIVATIVE
   1  p0           4.60707e+00   4.07462e-02   1.09841e-06  -1.28042e-02
   2  p1          -8.62719e-01   8.33215e-03   2.05688e-07  -8.63564e-02
   3  p2           9.84262e-04   1.20127e-03   2.86738e-08  -5.66097e-01
   4  p3          -1.45278e+09   2.00179e+08   3.46370e+02   5.24463e-13

ID155:
 FCN=8.93044 FROM HESSE     STATUS=NOT POSDEF     23 CALLS         325 TOTAL
                     EDM=1.56376e-09    STRATEGY= 1      ERR MATRIX NOT POS-DEF
  EXT PARAMETER                APPROXIMATE        STEP         FIRST
  NO.   NAME      VALUE            ERROR          SIZE      DERIVATIVE
   1  p0           3.36149e-01   4.05951e-02   1.02424e-06   1.66747e-02
   2  p1           5.96907e-01   8.27701e-03   1.78992e-07   9.42383e-02
   3  p2          -1.24128e-01   1.19514e-03   3.10496e-08   5.35879e-01
   4  p3          -5.49707e+08   1.98933e+08   1.31060e+02   2.34852e-13

ID156:
 FCN=27.107 FROM HESSE     STATUS=NOT POSDEF     23 CALLS         369 TOTAL
                     EDM=1.72237e-10    STRATEGY= 1      ERR MATRIX NOT POS-DEF
  EXT PARAMETER                APPROXIMATE        STEP         FIRST
  NO.   NAME      VALUE            ERROR          SIZE      DERIVATIVE
   1  p0          -6.26350e+00   4.21430e-02   1.78695e-06  -4.63010e-03
   2  p1           2.85365e+00   8.58127e-03   6.80363e-07  -2.64484e-02
   3  p2          -3.19389e-01   1.24245e-03   7.61484e-08  -1.51241e-01
   4  p3           1.16616e+09   2.05264e+08   2.78034e+02  -1.93778e-14

ID157:
 FCN=19.4716 FROM HESSE     STATUS=NOT POSDEF     23 CALLS         342 TOTAL
                     EDM=1.04278e-08    STRATEGY= 1      ERR MATRIX NOT POS-DEF
  EXT PARAMETER                APPROXIMATE        STEP         FIRST
  NO.   NAME      VALUE            ERROR          SIZE      DERIVATIVE
   1  p0          -3.89605e+00   4.09683e-02   1.48832e-06   3.26076e-02
   2  p1           2.04214e+00   8.37584e-03   4.86884e-07   1.83059e-01
   3  p2          -2.47352e-01   1.20710e-03   5.89732e-08   1.02761e+00
   4  p3           9.13701e+08   2.00155e+08   2.17843e+02   1.24035e-13

ID158:
 FCN=7.59955 FROM HESSE     STATUS=NOT POSDEF     23 CALLS         331 TOTAL
                     EDM=1.78742e-08    STRATEGY= 1      ERR MATRIX NOT POS-DEF
  EXT PARAMETER                APPROXIMATE        STEP         FIRST
  NO.   NAME      VALUE            ERROR          SIZE      DERIVATIVE
   1  p0          -8.46924e+00   4.17987e-02   2.01922e-06  -1.01596e-03
   2  p1           3.60905e+00   8.55091e-03   8.60466e-07   8.06431e-03
   3  p2          -3.83202e-01   1.23257e-03   9.13624e-08   1.28451e-01
   4  p3           1.94705e+09   2.02809e+08   4.64212e+02   1.90916e-13

ID159:
 FCN=24.8135 FROM HESSE     STATUS=NOT POSDEF     27 CALLS         314 TOTAL
                     EDM=7.91895e-10    STRATEGY= 1      ERR MATRIX NOT POS-DEF
  EXT PARAMETER                APPROXIMATE        STEP         FIRST
  NO.   NAME      VALUE            ERROR          SIZE      DERIVATIVE
   1  p0          -1.15142e+00   4.18270e-02   1.70735e-06   3.54687e-03
   2  p1           1.09795e+00   8.55588e-03   2.98767e-07   1.75400e-02
   3  p2          -1.67863e-01   1.23250e-03   5.18807e-08   8.63094e-02
   4  p3           1.96354e+08   2.02197e+08   4.87057e+05   3.05910e-13 


For comparison: EURICA total efficiency - see attachment 3
Entry  Sun Oct 22 05:15:26 2017, RG,RY,MS,ATD,JA,JLT, Check of YSO 12x
We start a systematic check of YSO in BRIKEN DACQ

WE check and correct a configuration file for YSO alone
Conf file: 171022_1306_YSO_Conf.xlsx

First measurement: 
change the light pulser attenuation and check 
changes of X and Y position
Root file: 171022_1314_pulserAtCenter.root

We change configuration file to remove amplitude 
range condition to buil position
New configuration file:171022_1332_YSO_Conf.xlsx

Now start moving the light pulser position using a mask:

Light pulse position: Top Left Out
Root file: 171022_1335_pulseTopLeftOut.root

Light pulse position: Bottom Left Out
Root file: 171022_1341_pulseBottomLeftOut.root

Light pulse position: Bottom Right Out
Root file: 171022_1345_pulseBottomRightOut.root

Light pulse position: Top Right Out
Root file:171022_1350_pulseTopRightOut.root

Light pulse position: Top Left In
Root file: 171022_1401_pulseTopLetIn.root

Light pulse position: Bottom Left In
Root file: 171022_1406_pulseBottomLeftIn.root

Light pulse position: Bottom Right In
Root file: 171022_1410_pulseBottomRightIn.root

Light pulse position: Top Right In
Root file: 171022_1416_pulseTopRightIn.root

Now we ramp the PMT high voltage starting at 600V: 
600V, 650V, 700V, 750V, 800V, 900V, 950V, 1000V, 1050V, 1100V, 1150V
Pulser at Top Left Out
Root file: 171022_1445_HVramp_pulseTopLeftOut.root
Entry  Tue May 5 05:04:00 2015, J.L. Tain, J. Agramunt, G. Kiss, Change of degrader thickness 
For EURICA measurements degrader thickness were increased
trying to decrease MACI and AIDA trigger rate
Before we had 5.7 mm of Al
Now we have: 
Degrader: 4.0 + 1.0 + 0.6 + 0.4 +0.3 = 6.3 mm of Al
also 2x 0.8mm Al plates were added before 
the MACI start detector (thus covering partially AIDA)
Trigger from AIDA will be taken from 3rd DSSSD
Entry  Tue Oct 24 13:14:47 2017, RY, Calibration data for clovers 171024_1858_152Eu_G7.root171024_2112_152Eu_D4.root

for energy calibration with 152Eu source

171024_1858_152Eu_G7.root
171024_2112_152Eu_D4.root

Entry  Fri Oct 20 05:33:11 2017, KR, NB, SG, RY, JL, AT: , Calibration and Resolution of D4 (after Repair)  IMG_20171019_105549066.jpgD4Oct19.ods

Green and Red channels were repaired by crimping and securing the grounding of the cables and fixing the cables securely to the table. 

All problems during the repair process were visible on the scope. See example attatched. 

Calibration is as:

Edit(10-21): NB realized calibration was not performed on the raw spectra, but on the previously calibrated ones. These values are wrong!

  Red Green Blue Black
m 0.427423220774017 0.998884435913729 2.37782285204219 0.98418344391708
b 0.530526265762205 0.578623397588558 0.699629095743376 -0.148161787849403
         

Calculation also attached

FWHM (keV) @ 1408 values were: 

Num Col FWHM (now) FWHM (before @ 1333)

G7 Red 3.06 2.77

G7 Green 2.81 2.84

G7 Blue 2.93 2.67

G7  Black  2.88 2.64

D4 Red 2.61 3.41

D4 Green 2.79 3.35

D4 Blue 2.88 3.60

D4 Black 3.17 4.85

 

Entry  Fri Oct 14 04:12:50 2016, JL Tain et al, CONF 
New configuration file: 
161014Conf_BrikenFull.xlsx
Entry  Thu May 25 13:24:02 2017, AT,PC,KR,JLT,AA, CLOVER, detector not in its rigth position 
We have noticed that D4 is not in its right position. That explains the different number of counts in the
detectors. 
Probably of the order of 3 cm away from its nominal place.
The position of the other detector should be also checked.
Efficiency calibrations need to be repeated 
Entry  Thu May 25 09:51:37 2017, A.T, A.A, CLOVER, Ba133 170525_133Ba_D4_D4pulser.png
Source details:

Diameter: 25.05 mm
Dz: 3 mm
Source ID: CD 392

With pulser
Start:17:45
Stop: 18:08

Files saved:

170525_1146_152Eu_z0cm_D4Pulser.root
170525_1745_133Ba_z0cm_PulserD4_002.dlt

Ps. See that the pulser generates peaks in the region 250-270 keV (to avoid people to invent new levels (and
gammas) populated 
in the beta decay of 133Ba). 
Entry  Fri May 26 03:52:23 2017, AT,AA,JLT, CLOVER, 137Cs 
137Cs, No AIDA, Efficiency calibration

Source ID: 393
Same type as 133Ba

Start: 11:51
Stop: 12:10

Files:

170526_1151_137Cs_noAIDA_z0cm_016.dlt
170526_1151_1210_137Cs_z0cm.root
Entry  Thu May 25 10:15:02 2017, A.T, G. K, A.M, A. A, CLOVER, 133Ba no pulser 
Source in position z=0 with the carton (cardboard) high-end, high-tech holder, but no AIDA (of course).
No pulser. Remember that the pulser is providing peaks around 

Start: 18:11
Stop: 18:31

Files
170525_1811_133Ba_z0cm_003.dlt
170525_1831_133Ba_z0cm_noD4Pulser.root
Entry  Fri May 26 03:24:38 2017, GK,VP, AT, AA, CLOVER, 133Ba 
133Ba source efficiency calibration, no AIDA

Start: 11:23
Stop: 11:43

Files: 
170526_1123_133Ba_noAIDA_z0cm_015.dlt
170526_1123_1143_133Ba_z0cm.root
Entry  Sun May 28 11:41:24 2017, YS, CLOVER energy calibration 
Clover calibration with 152Eu

Used peaks [keV]: 121.7817, 244.6975, 344.2785, 444.000, 778.9045, 867.378, 964.100, 1112.074, 1408.011
Up to 444keV is lower energy region, above 778.9045 is higher energy region.
All the peaks were fitted with Gaussian + Second Order Plolinomial(background) + Step Function(background). 

Parameters: Second Order, First Order, Offset
ID 152 Lower: 1.14254e-08, 1.57915, 408.94
ID 152 Higher: -3.90753e-10, 1.58167, 1224.11

ID 153 Lower: -7.33088e-09, 1.54588, 264.002
ID 153 Higher: 4.72241e-09, 1.53548, 3541.56

ID 154 Lower: -4.45069e-08, 1.54978, -626.916
ID 154 Higher: -4.48059e-08, 1.58933, -14795.7

ID 155 Lower: -5.93726e-10, 0.666536, 230.739
ID 155 Higher: 1.74281e-09, 0.659392, 3973.56

ID 156 Lower: -4.00636e-09, 0.708287, -509.227
ID 156 Higher: 9.5416e-11, 0.705004, -1574.59

ID 157 Lower: -2.94588e-09, 0.686728, -572.626
ID 157 Higher: 3.24943e-10, 0.683273, -1684.07

ID 158 Lower: 1.30198e-09, 0.668335, 485.045
ID 158 Higher: -4.572e-10, 0.67108, -3189.18

ID 159 Lower: -4.37028e-09, 0.701927, -666.22
ID 159 Higher: 3.40354e-09, 0.685865, 8115.55
ELOG V3.1.4-unknown