AIDA GELINA BRIKEN nToF CRIB ISOLDE CIRCE nTOFCapture DESPEC DTAS EDI_PSA 179Ta CARME StellarModelling DCF K40
  BRIKEN, Page 17 of 21  ELOG logo
Entry  Tue Nov 8 11:51:28 2016, Ale, spikes on some spectra 
Some spectra show spikes or do not look normal. This should be checked.

Look at BRIKEN, Ring4, Ring5, Ring6, Ring7, D4, G7, Clovers, 
Entry  Tue Nov 22 10:17:57 2016, ATS, PV, LIU, 252Cf 161122_2208_003_BRIKEN.svg
Measurement with 252Cf at Z=22.5cm from the moderator border, opposite side from AIDA.
Clovers and Veto detectors are turned off.
Beam is off.
Entry  Thu Oct 25 09:07:00 2018, ATS & JLT, BRIKEN Calibration check 
We put the 252Cf source and check the aligment of 3He tubes gains:

File: 181025_1600_252Cf_gaincheck.root
Entry  Thu Oct 25 09:18:24 2018, ATS & JLT, F11 plastic 
F11 plastic (long plastic after MUSIC chamber) 
connected to DACQ.
The connections were re-cabled and verified.
Entry  Thu Oct 25 16:04:17 2018, ATS & JLT, Background 
Background BRIKEN control measurement
No DLT
Entry  Thu Oct 25 16:08:53 2018, ATS & JLT, Lead bricks 
Lead bricks in BRIKEN hole to protect AIDA
Entry  Fri Oct 26 03:24:25 2018, ATS & JLT, Background 
Background BRIKEN control measurement
No DLT
Entry  Fri Oct 26 03:57:37 2018, ATS & JLT, Background 
Background BRIKEN control measurement
No DLT
Entry  Tue Oct 16 03:15:03 2018, ATD & JLT, Start of REP run preparation (RIBF148) Screenshot_from_2018-10-16_14-57-33.png
16-Oct-2018

- Start DACQ computer: OK!
Entry  Tue Oct 16 08:57:56 2018, ATD & JLT, 252Cf source 181016_1656_252Cf.root
252Cf source Run 
START:?
STOP: 16:56
Entry  Tue Oct 16 09:00:02 2018, ATD & JLT, Background measurement overnight He121.png

18/10/16 START: 16:56
18/10/17 STOP: 9:51
Entry  Thu Oct 18 08:21:18 2018, AT2, JLT, SN, 252Cf long measure, z=0cm, no clovers 

18/10/18 START: 17:22
18/10/18 STOP: 20:09
Entry  Thu Oct 18 12:16:39 2018, AT2, JLT, SN, 252Cf long measure, z=15cm beam upstream, no clovers 

18/10/18 START: 20:20
18/10/18 STOP: 23:17
Entry  Thu Oct 18 15:24:40 2018, AT2, JLT, SN, 252Cf long measure, z=25cm beam upstream, no clovers 

18/10/18 START: 23:23
18/10/19 STOP: 08:23
Entry  Fri Oct 19 00:28:48 2018, AT2, JLT, SN, background measurement, no clovers Screenshot_from_2018-10-19_10-47-54.pngScreenshot_from_2018-10-19_10-55-30.png

18/10/19 START: 08:31
18/10/19 STOP: 10:50
Entry  Fri Oct 26 03:31:33 2018, AT2 & JA, Test pulser effect on baseline 6x
We have tested possible change of the baseline in the digitizer due to the pulser connection. NO EFFECT has been
found!
Entry  Thu May 25 13:24:02 2017, AT,PC,KR,JLT,AA, CLOVER, detector not in its rigth position 
We have noticed that D4 is not in its right position. That explains the different number of counts in the
detectors. 
Probably of the order of 3 cm away from its nominal place.
Entry  Fri May 26 03:52:23 2017, AT,AA,JLT, CLOVER, 137Cs 
137Cs, No AIDA, Efficiency calibration

Source ID: 393
Entry  Thu May 25 13:42:45 2017, AT, PC,KR,JLT,AA, 252Cf 
252Cf source in Z=0cm position. 

Start:21:41
Entry  Thu May 25 13:38:11 2017, AT, PC, KR, JLT, AA, Clover, detectors in new position CLOVER-sketch.jpgD4-insertion.jpgG7-insertion.jpg
Both clover detectors were moved. They are in a symmetrical position. The end on the clover nose is of the order
of 3-4 mm from the AIDA tunnel.
ELOG V3.1.3-7933898