Entry  Tue Mar 1 22:10:26 2022, David, George, Current status 2022-03-01_23-14-43aida.png2022-03-01_23-13-57exrate.png2022-03-01_23-13-40xyto.png2022-03-01_23-13-10extot.png

Ring current 6.67e7 particles/s

pressure at S1: 2.3-2.8e-8

Merger, Tape server (WS3): 1574 kB/s, writing ok

Leakage current (WS4): 3.20 uA

DAQ (WS2): temperature checked, clock status: ok, adc calibration: ok, white rabbit check: failed

Online monitoring (WS 5): done

Entry  Tue Mar 1 21:34:06 2022, PM, LV, check 14x

no change:

Check Clock Status': Passed 5, Failed 0

Check ADC Calibration: Passed 5, Failed 0

'Check the White rabbit decoder status: Passed 0, Failed 5

 

target density at S1: 2.2-2.7e-8

temp: 110K

beam at injection: 7e7

Entry  Tue Mar 1 20:41:28 2022, PM, LV, check 14x

no change:

Check Clock Status': Passed 5, Failed 0

Check ADC Calibration: Passed 5, Failed 0

'Check the White rabbit decoder status: Passed 0, Failed 5

 

target density at S1: 2.3-2.7e-8

temp: 110K

beam at injection: 7e7

Entry  Tue Mar 1 19:41:24 2022, PM, LV, target temperature walkthrough 

A target temperature walkthrough has been initiated at 20:41 since the target density at S1 had slightly decreased (with ~0.1-0.2)

Current temprature 116K

set to 126K at 20:41

set to 95K at 20:47:30

set to 108.5K at 21:01:30, at this temperature was a sweetspot observerd for target density.

set to 109.7 at 21:08:30

set to 110K at 21:13:30 - we keep at this value for a while. the values at S1 are changing between 2.2-2.9e-8

Entry  Tue Mar 1 19:40:28 2022, PM, LV, check 12x

no change:

Check Clock Status': Passed 5, Failed 0

Check ADC Calibration: Passed 5, Failed 0

'Check the White rabbit decoder status: Passed 0, Failed 5

 

target density at S1: 2.1-2.3e-8

temp: 116K

beam at injection: 7e7

Entry  Tue Mar 1 18:43:41 2022, PM, LV, check 14x

no change:

Check Clock Status': Passed 5, Failed 0

Check ADC Calibration: Passed 5, Failed 0

'Check the White rabbit decoder status: Passed 0, Failed 5

 

target density at S1: 2.1-2.4e-8

temp: 116K

Entry  Tue Mar 1 17:36:04 2022, PM, LV, check 14x

no change:

Check Clock Status': Passed 5, Failed 0

Check ADC Calibration: Passed 5, Failed 0

'Check the White rabbit decoder status: Passed 0, Failed 5

 

target density at S1: 2.1-2.4e-8

temp: 116K

Entry  Tue Mar 1 16:57:34 2022, CB, LV, PMH, New run 

Beam issues due to too long storage time in the last hours. Motors moved out and not moving.

Decreased storage time to 70 s. Seems OK now. Restarted motor movement as before

Started new run R86

Entry  Tue Mar 1 14:01:01 2022, MS, SHB, check 11x

'Check Clock Status', 'Check ADC Calibration' and 'Check the White rabbit decoder status' : no change

Entry  Tue Mar 1 12:58:32 2022, CB, MS, SS, ML, Synced pneumatic motion 

New run R84

Attempting to sync pneumatic movement with ring. Still see something on t out -> p out

Command to move out was being given relative to the wrong time.

Fixed it. Still see one-two events every time we move out around 4-6 MeV. Attempted to greatly increase time before next injection - no difference. Microphonics from moving the detectors? It's just one-two counts on entire detector, acceptable.

 

New run R85

Now moving in/out

Potentiometer: 23.10 mm to 67.19 mm

Entry  Tue Mar 1 12:33:21 2022, MS, SHB, check 11x

'Check Clock Status', 'Check ADC Calibration' and 'Check the White rabbit decoder status': no change

Entry  Tue Mar 1 10:43:36 2022, MS, SHB, check  11x

'Check Clock Status', 'Check ADC Calibration' and 'Check the White rabbit decoder status': same

 

Entry  Tue Mar 1 10:35:59 2022, MS, SHB, next run on tape server tab 

old potentiometer position 19.1 mm

new run number: 83

new potentiometer position : 27.58 mm

 

Entry  Tue Mar 1 08:02:26 2022, SHB, MS, check 11x

 

'Check Clock Status', 'Check ADC Calibration' and 'Check the White rabbit decoder status' - no changes

Entry  Tue Mar 1 06:35:42 2022, SHB, MS, check 11x

detector motors are still out

'Check Clock Status', 'Check ADC Calibration' : Clock status test result: Passed 5, Failed 0

'Check the White rabbit decoder status' :  
         Base         Current     Difference
aida01 fault      0xab60 :      0xab8f :      47  
aida02 fault      0x88d3 :      0x8901 :      46  
aida03 fault      0x23aa :      0x23d9 :      47  
aida04 fault      0x15d7 :      0x1606 :      47  
aida05 fault      0x2f03 :      0x2f0f :      12  
White Rabbit error counter test result: Passed 0, Failed 5

Understand the status reports as follows:-
Status bit 3 : White Rabbit decoder detected an error in the received data
Status bit 2 : Firmware registered WR error, no reload of Timestamp
Status bit 0 : White Rabbit decoder reports uncertain of Timestamp information from WR

Entry  Tue Mar 1 06:04:04 2022, SHB, MS, positions 

just FYI: current positions saved in files are x=1000 and y=-750. this information is good in case of crash.

 

Entry  Tue Mar 1 05:23:02 2022, JM, EM, Current status  2022-03-01_06-42-53-ExRate.png

06:20

Servo motors moved to fully out position as some work on the beam was neccessary. Beam injection had dropped from ~9e7 to around 1e7. Potentiometer reads 19.10 mm.   

Still trying to improve target density. Current setpoint 100 K.

Merger OK

Data rate = 1600 kb/sec

Leakage current = 3.21 uA

System checks OK - wr fails

         Base         Current     Difference
aida01 fault      0xab60 :      0xab8e :      46  
aida02 fault      0x88d3 :      0x8900 :      45  
aida03 fault      0x23aa :      0x23d8 :      46  
aida04 fault      0x15d7 :      0x1605 :      46  
aida05 fault      0x2f03 :      0x2f0f :      12  
White Rabbit error counter test result: Passed 0, Failed 5

Understand the status reports as follows:-
Status bit 3 : White Rabbit decoder detected an error in the received data
Status bit 2 : Firmware registered WR error, no reload of Timestamp
Status bit 0 : White Rabbit decoder reports uncertain of Timestamp information from WR

Avg ring pressure = 4.3E-10 mbar.

06:40

Target density still very low. Setpoint back to 116 K. Detectors still fully out, very low rutherford rate.

Attempted to move nozzle to increase density, already on maximum point. 

06:50

Setpoint to 95 k. Small increase in target density, however this was temporary

 

Entry  Tue Mar 1 04:07:31 2022, JM, EM, Temperature cycle 

Have been unable to achieve decent target density with temperature cycling so far. Will attempt to go up to 300 k and back down to around 115 k which proved successful in previous shifts.

Entry  Tue Mar 1 03:34:28 2022, JM, EM, Current status 7x

Temperature setpoint = 116 k

Detector IN potentiometer = 34.89 mm

Rutherford rate is reduced from previous entries. Avergae peak height appears to be ~50 counts. Fluctuations in peak height and E4 pressure are quite high. Temperature has been cycled, nozzle position has been optimised and different temperatures have been trialled however density cannot be maintained at a decent level. 

Merger OK

Data rate ~ 1500 kb/sec

Leakage current = 3.2295 uA

Temperatures OK

System checks OK - wr fails

         Base         Current     Difference
aida01 fault      0xab60 :      0xab8c :      44  
aida02 fault      0x88d3 :      0x88fe :      43  
aida03 fault      0x23aa :      0x23d6 :      44  
aida04 fault      0x15d7 :      0x1603 :      44  
aida05 fault      0x2f03 :      0x2f0f :      12  
White Rabbit error counter test result: Passed 0, Failed 5

Understand the status reports as follows:-
Status bit 3 : White Rabbit decoder detected an error in the received data
Status bit 2 : Firmware registered WR error, no reload of Timestamp
Status bit 0 : White Rabbit decoder reports uncertain of Timestamp information from WR


Avg ring pressure = 4.4 E-10 mbar

Entry  Tue Mar 1 03:19:50 2022, JM, EM, Temperature Cycle 

04:20

Did another temperature cycle (118 K -> 125 K -> 95 K -> 116 K) trying to improve the pressures at the target and the detector count rate.

Rates are still mostly below 100 counts (Ex rate) and the pressures are still fluctuating by about an order of magnitude (E4: between 1e-9 and 1e-8 mbar).