AIDA
GELINA
BRIKEN
nToF
CRIB
ISOLDE
CIRCE
nTOFCapture
DESPEC
DTAS
EDI_PSA
179Ta
CARME
StellarModelling
DCF
K40
DTAS, Page 3 of 8
New
|
Find
|
Select
|
Import
|
Config
|
Last day
|
Help
Full
| Summary |
Threaded
-- All entries --
Last day
Last 3 Days
Last week
Last month
Last 3 Months
Last 6 Months
Last Year
142 Entries
Goto page
Previous
1
,
2
, 3,
4
...
6
,
7
,
8
Next
All
Selected entries:
ID
Date
Author
Subject
Text
117
Tue Jun 11 01:45:55 2019
Pancho, Ale
background
Start: 09:46
1
Tue May 14 09:41:24 2019
TD
Welcome to the DTAS Elog
127
Sun Jun 16 02:07:29 2019
Victor
Total sum (black) and anodes
Different cuts at high energy in individual
spectra (anodes) and effect in the total
sum
143
Mon Jun 17 19:12:33 2019
Victor
Total SUM in coincidence with AIDA Plastic
Also TAC DTAS-Plastic AIDA
132
Sun Jun 16 07:31:01 2019
Victor
The bump in the mutiplicities
We have calculated the spectra of the module
multiplicity for each side (careful! the
maximum is 8, since it is
8x
110
Mon Jun 10 08:07:17 2019
Ale, Jose
Test of pulser count rates
File: 20190610_1602_background_AIDA_in.root
SyncPulse: 61777
142
Mon Jun 17 19:11:06 2019
Victor
TAC slowest module vs fastest module DTAS
Inside events of 320ns window
81
Fri May 31 06:48:58 2019
A. Algora
T spectra for AIDA and F11 plastics
T spectra for AIDAPL and F11PLL and F11PLR
are defined from now on. The ancilliary card
was not saving the CFD values for all channels.
3
Wed May 15 04:03:23 2019
JAR
Synchronization with AIDA working
Synchronization with AIDA is working, see
attached document to proceed.
136
Sun Jun 16 22:02:45 2019
Victor
Sum in coincidence with F11
TAC DTAS (slowest module of the sum) and F11
Total sum in coincidence with F11
6
Wed May 15 07:48:08 2019
Kiss Algora Nacher
Saturation and pulser
Saturation and pulser position after calibration
EDy1 16801 25000
42
Thu May 23 04:18:57 2019
A. Algora
SY2527 fixed
Following the instructions of CAEN, the
SY2527 is working again. Some pushing, massaging
appear to solve the situation
62
Tue May 28 05:30:03 2019
A. Algora
Reference detector threshold changed
Again the Reference detector was firing
mainly in the noise. Threshold increased
to 5000 !!!!
59
Mon May 27 12:54:48 2019
A. Algora
Reference detector
The reference detector was very noisy.
The threshold has been changed from 2000
to 3200. We should look at this more carefully.
72
Thu May 30 02:03:33 2019
A. Algora
Ref detector position changed, AIDA plastik HV changed
The position of the reference detector
in the ancilliary card was changed from channel
10 to channel 9. Remember that this is important
70
Wed May 29 09:49:25 2019
A. Algora
New configuration file
New configuration file after a few small
changes in thresholds.
94
Mon Jun 3 12:56:06 2019
A. Algora
New configuration file
The E range of the AIDA plastic for the
construction of the TAIDA plastic spectrum
has been changed. Also the range of the TAC_AIDAPL_CryA
19
Mon May 20 06:55:15 2019
A. Algora
New config file after calibration
A file with Co and Cs was collected for
10 min
201905201444_137Cs60Co_align.root
84
Fri May 31 14:17:13 2019
A. Algora
New config file
A new config file provided by Jose and
Alvaro is loaded
cp 20190531_Conf_JLTAT.xlsx 20190531_Conf_2.xlsx
114
Mon Jun 10 12:31:52 2019
Ale, Jose
New calibration
New calibration with more statistics
File: 20190610_2030_60Co_137Cs_AIDA_in.root
Goto page
Previous
1
,
2
, 3,
4
...
6
,
7
,
8
Next
All
ELOG V3.1.4-unknown