Entry  Mon Oct 8 17:02:47 2018, DK, Target ladder photo from previous experiment IMG_1274.jpg
From Alex, attached.
Entry  Tue Oct 9 10:40:13 2018, DK, To-do Meeting Notes: July, August, September, October 6x
Each month's notes are attached.  Unfinished business naturally carries over to the next month.

This elog will be updated with new notes as necessary.
Entry  Tue Oct 9 14:25:54 2018, DK, Au foil request to STFC NPG_-_Online_Target_Request.pdf
http://npg.dl.ac.uk/TargetRequests/

https://www.technologysi.stfc.ac.uk/Pages/Target-frames.aspx
Entry  Wed Oct 10 10:57:33 2018, DK, Chamber wheel bolt spacing WhatsApp_Image_2018-10-10_at_09.14.43.jpeg
From Ruchi's friend Rob.
Entry  Wed Oct 31 14:50:36 2018, DK, Strut shipping info 
http://www.dhl.com/en/express/tracking.html?AWB=1647723055&brand=DHL
Entry  Wed Oct 31 16:01:33 2018, DK, Measuring foil thickness DOC_(4).PDFDOC_(5).PDF
A couple scans from my notes which may be useful.

One discusses alpha energy loss in nominal kitchen foil (~12 um) and also introduces my technique to calibrate a thin (~20 um) SSD.  Sorry I forget which
Entry  Fri Nov 2 17:01:16 2018, DK, Inventory going to CERN by easyJet 
Conor will take:

==Black clicker case==
Entry  Tue Sep 19 14:54:47 2017, Claudia, Toby, Setup Photos 14x
 
Entry  Tue Mar 14 10:57:20 2017, Claudia , Meeting Edinburgh 14 March 10 am 2017 
1) DAQ

We have 192 channels to DAQ working. Mirco will test the silicon detectors with an alpha source in the next 2 weeks. 

2) Vacuum
Entry  Sat Sep 9 09:39:38 2017, Claudia, Vacuum Readings at ISOLDE Hall 
Thursday, 7th September:

Vaccum after pumping all night preamps off, chiller off


09:37: IMG1 2.3E-5 mbar, Chamber 7.5 E-5 mbar; Julabo off;
09:38: IMG1 2.1E-5 mbar; Chamber 6.6E-5 mbar; Julabo 20 Celsius
09:41:
Entry  Thu Sep 14 08:37:27 2017, Claudia, Detector installation 8x
dE detector: 2083-9, 74 um thick, V_depletion=12V; V_operating=24 V

E detector:  3080-23, 1012 um thick, V_d=110; V_o=350 V

HI detector: 2410-23, 65 um; V_d=7 ; V_o=14 V
Entry  Thu Sep 14 10:24:34 2017, Claudia, Detector - ADC connection 
ADC#1 0-31: p+n dE

ADC#2 32-48: n+n dE

ADC#2 49-64: p+n dE
Entry  Thu Sep 14 10:29:25 2017, Claudia, Alpha Calibration 
Run 1-10 Test

14 September 2017

Run 11 Start 18:16 (CERN time)
Entry  Thu Sep 21 14:54:00 2017, Claudia, Alpha Calibration Spectra Screenshot_from_2017-09-21_14-43-48.pngScreenshot_from_2017-09-21_14-43-17.png
Alpha Calibration Runs (need to check settings in logbook)

0-63: dE detector and 32-47 is n+n;  64-127 E detector and 96-111 is n+n; 128-191 HI detector

Run 13:  alpha source in fromt of dE detector (0-63). All detectors connected.
Entry  Thu Oct 5 11:34:34 2017, Claudia, Meeting 5.10.17 
POINTS FOR DISCUSSION

 


Email sent to Karl and Olof about 
FC at end of SEC
Gain resistor package
Network access
N2
Entry  Thu Oct 12 12:45:54 2017, Claudia, Meeting 12.10.17 
Email sent to Karl and Olof about 


FC at end of SEC
Gain resistor package
Network access
N2 gas
date for connection of SEC to
our chamber
collimator in front of chamber ?


Next week call Karl. Daid will look at old Olof emails
Entry  Thu Oct 19 10:55:54 2017, Claudia, Meeting 19.10. 
CERN-Edinburgh Liaison


FC at end of SEC: manual
Network access: port free.
N2 gas ? 
-date for connection of SEC to our
chamber: week 30. October, 2nd November alignment. 
collimator in front of chamber ?? contact Jorge Alberto about beam tuning in general
Entry  Thu Nov 9 08:20:21 2017, Claudia, Restarting Target Current & Line Current 
0) If target or line drop, STOP THE BEAM!!

1) If you SEE target or line current go down (top right window of monitors next to the corridor): 

Use Knobs open application (monitor below); remember set value; type 0 in set window; click Mode - Reset; click Mode - On. increase current in
Entry  Fri Nov 10 16:32:19 2017, Claudia, RAL Amplitude Thresholds 
Thresholds of RAL amplifiers set to: dE 30mV; E 20 mV, HI 20 mV
Entry  Sat Nov 11 07:45:34 2017, Claudia, Checking Laser quality 
There is an option to see when the beam is gone if it is due to lasers or due to the accelerator.

- window next to proton requestion switch

- put middle faraday cup in