Wed May 24 15:58:53 2017, Patrick Coleman-Smith, Examination of Console Logs -- and a couple of reminders
|
Quote:
|
Wed Sep 10 09:27:43 2014, Patrick, Elog appreciation
|
| This is very interesting. Look forward to many happy interactions. |
Mon Sep 15 13:51:28 2014, Patrick, Odd spectra from running nnaida2 for 3 hours
|
I'm running nnaida2 with the PB-5 and an old adaptor.(1pF)
I've seen spectra like this before but previously they have shown apparent digital relationship between the troughs.
So maybe they show 3 peaks ? |
Wed Jan 14 15:29:01 2015, Patrick, Filtered switch mode PSU performance
|
Trying the AIDA format power supply with the simple filters installed.
The detector is attached and HV of 200v@3.8uA
Using one channel from each FEE64 as a guide to compare performance. Using the Integrate analysis function Peak width. |
Thu May 5 14:44:48 2016, Patrick, Trigger selection explanations
|
| Please request more information if the attached is not clear. |
Mon May 9 16:46:30 2016, Patrick, Update for FEE64 VHDL and Correlation browser windows 
|
The attached VHDL file should be saved to /MIDAS/Aida and the FlashPgm.csh file edited to load "FEE_GF_Feb16_16.bin"
Use the Run Control Expert command
to update the firmware on all the FEE64s.
Power cycle the FEE64s.
This will give a 25Mhz clock from the MACB Fast NIM output 0.
The attached .js
and .tml files will change the Control browser window to allow access to a Correlation control window.
I have already installed the Correlation directory |
Wed May 11 11:24:09 2016, Patrick, Correlation Controls
|
Please note that the Force Trigger and Reset buttons in the Correlation Browser only have meaning if the FEE64
selected is the Master. |
Thu May 12 15:50:48 2016, Patrick, System Checks and firmware update 
|
Added two checks to the System wide checks.
Modified the Firmware so the checks work properly.
One check reads the status of the FEE64 clocks and checks
against expected value.
The other check reads the value from all the FEE64 Sync Error Counters, pauses for one second, then reads them again and compares
with the first reading. Any change is reported as an error.
The Sync Error counter is incremented if the SYNC pulse arrives at a FEE64 when the Timestamp |
Mon May 22 09:12:56 2017, Patrick, Consoles reporting Options not available.... defaults operational ?
|
I have noticed from the console logs reports concerning an inability to open the Options CONTENTS files for the FEE64s and hence failure to load the
Options.
I have checked with similar files on nnsa here in Daresbury and they are set for permissions "-rwxrwxrwx. 1 npg npgstaff 1115 |
Mon May 22 10:21:29 2017, Patrick, Console mapping to FEE64 please
|
Please attach the list of ttyUSB to FEE64 console connection .
|
Thu Dec 1 08:13:06 2016, PV,Liu, TD, Implantation profile in AIDA , after changing the ZDS setting to center at 41Al, AIDA 43_ 33 to 43  
|
Bigrips run 1127
AIDA run 43_ 33 to 43 |
Thu Dec 1 10:58:54 2016, PV, TD, Liu, Implantation profile in AIDA , after switch back to the previous ZDS setting (AIDA 43_63 to 43_71, bigrips run 1129)  
|
| |
Wed Nov 30 06:31:04 2016, PV, TD, RCF, Liu, Implantation profile in AIDA R39 2 to 9, after changing degrader at 13:30  
|
Degrader setting was:
Variable degrader:
0.5 mm W + 1 mm Al : in
|
Wed Nov 30 08:41:37 2016, PV, TD, RCF, Liu, Implantation profile in AIDA R39 37 to 46, after changing degrader at 16:23  
|
Degrader setting:
Variable degrader:
0.5 mm W + 1 mm Al : in
0.3 mm W + 1 mm Al : in
1 mm W + 1 mm Al : in
Fix degrader:
20mm Al+ 0,2 mm Al
See
https://elog.ph.ed.ac.uk/AIDA/502 for comparison |
Mon Nov 28 13:12:31 2016, PV, AE, Liu, Implantation profile in AIDA with 8mm Al replacing 3 mm Pb    
|
Data for ~3 hrs: Nov 28th, 20:06 to 23:16
Bigrips run 1060 to 1062
AIDA run R30_ 2 to R30_40 |
Sun May 28 09:55:11 2017, PV, ADC offset value from pulser walkthrough run May2017/R28 R29   
|
ADC offset calculation using data from pulser walkthrough runs, see:
https://elog.ph.ed.ac.uk/AIDA/603
|
Fri Jun 9 16:22:54 2017, PV, Saturday 10 June 00:00-08:00 28x
|
00:21 BigRIPS and BRIKEN stop their DAQ
AIDA run file R7_826
|
Sun Jun 11 08:23:23 2017, PV, Sunday 11 June 16:00-00:00 21x
|
16:40 beam lost - stripper foil problem
AIDA file RIBF128/R9_55
|
Tue Jun 6 00:57:49 2017, PJW, TD, Tuesday 6 June 08.00-16.00 16x
|
08.57 Stop DAQ
AIDA file RIBF128/R6_24
|
Mon Feb 22 15:19:52 2016, PJCS, T9 System changed to version 8
|
I have changed the T9 system to be using Version 8.
Tests using the detector and pulser seem to be ok.
Transmission to the Merge and Merging operating ok |