  AIDA, Page 9 of 46  ELOG logo
  ID Date Author Subject
  784   Wed Nov 14 14:46:47 2018 CAThursday 15th November 00:00 - 08:00
23.58 DAQ continues ok (RIBF148/R5_505)

00.09 system wide checks ok, except nnaida7 ADC calibration failure
      FEE64 temperatures ok (attachment 1)
      good event statistics ok (attachment 2)
      detector bias/leakage currents ok (attachment 3)

00.13 Merger and TapeServer run ok (attachment 4/5)

00.26 BRIKEN stop
      AIDA file RIBF148/R5_509

00.29 BRIKEN start
      AIDA file RIBF148/R5_510
      BRIKEN run 70
      BigRIPS run 1055

01.46 BRIKEN stop
      AIDA file RIBF148/R5_523

01.49 BRIKEN start
      AIDA file RIBF148/R5_523
      BRIKEN run 71
      BigRIPS run 1056

02.05 system wide checks ok, except nnaida7 ADC calibration failure
      FEE64 temperatures ok (attachment 6)
      good event statistics ok (attachment 7)
      detector bias/leakage currents ok (attachment 8)
      Merger and TapeServer still ok

02.34 XY hit patterns (attachment 9)
      Ex vs Ey plots (attachment 10)
      HEC spectra (attachment 11)
      LEC spectra (attachment 12)

02.49 BRIKEN stop
      AIDA file RIBF148/R5_534

02.50 BRIKEN start
      AIDA file RIBF148/R5_534
      BRIKEN run 72
      BigRIPS run 1057

03.26 zeroed all spectra on online analysis and MIDASsort

04.04 BRIKEN stop
      AIDA file RIBF148/R5_546

04.05 BRIKEN start
      AIDA file RIBF148/R5_546
      BRIKEN run 73
      BigRIPS run 1058

04.10 system wide checks ok, except nnaida7 ADC calibration failure
      FEE64 temperatures ok (attachment 13)
      good event statistics ok (attachment 14)
      detector bias/leakage currents ok (attachment 15)
      Merger and TapeServer still ok

05.06 BRIKEN stop
      AIDA file RIBF/R5_556

05.07 BRIKEN start
      AIDA file RIBF148/R5_557
      BRIKEN run 74
      BigRIPS run 1059

05.08 First 200ms of decay correlations in all detectors
      comparison between different Al degrader thickness values (3mm, 2.3mm, 2.8mm)
      see attachments 16, 17 and 18 - graphs labelled with detector number and Al degrader thickness

06.09 BRIKEN stop
      AIDA file RIBF148/R5_567

06.11 BRIKEN start
      AIDA file RIBF148/R5_567
      BRIKEN run 75
      BigRIPS run 1060

06.16 system wide checks ok, except nnaida7 ADC calibration failure
      FEE64 temperatures ok (attachment 19)
      good event statistics ok (attachment 20)
      detector bias/leakage currents ok (attachment 21)
      Merger and TapeServer still ok

06.17 ASIC check load - ok

06.34 XY hit patterns (attachment 22)
      Ex vs Ey plots (attachment 23)
      HEC spectra (attachment 24)
      LEC spectra (attachment 25)

07:12 BRIKEN stop
      AIDA file RIBF148/R5_578

07:15 BRIKEN start
      AIDA file RIBF148/R5_578
      BRIKEN run 76
      BigRIPS run 1061






      
















      
  783   Wed Nov 14 07:43:35 2018 TDWednesday 14 November 16:00 - 00:00
16.44 DAQ continues OK - AIDA file RIBF148/R5_432
      165Pm BigRIPS setting + 2.8mm Al degrader

      ASIC settings 2018Oct03-13.26.58
       from c. 09.00 13.11.18
       n+n FEE64s Ibias LF feedback 0xb -> 0xd
       HEC fast comparator threshold 0x20 -> 0xff

      BNC PB-4 pulser 
      Amplitude 90,000, x5 attenuator IN
      t_r 50ns tau_d 1ms
      Frequency min
      Delay min
      
16.45 BigRIPS and BRIKEN stop
      AIDA on File R5_432

16.48 BigRIPS starts run 1047
      BRIKEN starts run 62
      AIDA on file R5_433

16.57 online MIDASsort

      m_p versus m_n (LEC) - attachment 1
      x versus y (LEC) - attachment 2
      E_p versus E_n (LEC) - attachment 3
      m_p versus m_n (HEC) - attachment 4
      x versus y (LEC) - attachment 5
      E_p versus E_n (LEC) - attachment 6

      all MIDASsort spectra zero'd

17.17 file RIBF128/R5_436 ADC data synchronised - attachment 7
      analysis of RIBF148/R5_436 - attachment 8
       max dead time nnaida19 ~0.25%

17.48 BigRIPS and BRIKEN stop
      AIDA on File R5_443

17.48 BigRIPS starts run 1048
      BRIKEN starts run 63
      AIDA on file R5_443

18.45 BigRIPS and BRIKEN stop
      AIDA on File R5_452

18.47 BigRIPS starts run 1049
      BRIKEN starts run 64
      AIDA on file R5_453

19.45 BigRIPS and BRIKEN stop
      AIDA on File R5_463

19.46 BigRIPS starts run 1050
      BRIKEN starts run 65
      AIDA on file R5_463

20.49 BigRIPS and BRIKEN stop
      AIDA on File R5_473

20.49 BigRIPS starts run 1051
      BRIKEN starts run 66
      AIDA on file R5_473

21.49 BigRIPS and BRIKEN stop
      AIDA on File R5_483

      ASIC check load

21.50 BigRIPS starts run 1052
      BRIKEN starts run 67
      AIDA on file R5_484

22.00 all system wide checks OK *except* nnaida7 fails ADC calibration

      detector biases & leakage currents OK - see attachments 9 & 10

      FEE64 temperatures OK - see attachment 11
      good event statistics OK - see attachments 12

      Merger OK - see attachment 13
      TapeServer OK - see attachment 14
      1x merger error message reported - trying to add items to Q index 12 (Link 12) but queue alreday full

      per FEE64 Rate spectra - attachment 15

      1.8.L spectra - attachments 16 & 17
       nnaida1 pulser peak width 73 ch FWHM
      1.8.H spectra - attachments 18 & 19
      1.8.W spectra 20ms FSR - attachments 20 & 21


22.48 BigRIPS and BRIKEN stop
      AIDA on File R5_493

22.50 BigRIPS starts run 1053
      BRIKEN starts run 68
      AIDA on file R5_493

23.24 BRIKEN DAQ found stopped - no sync check data - BigRIPS DAQ stopped and restarted
      AIDA on File R5_499

23.26 BigRIPS starts run 1054
      BRIKEN starts run 69
      AIDA on file R5_499


      
  782   Tue Nov 13 22:58:49 2018 OH Wednesday 14 November 08:00 - 16:00
08:01 BigRips and BRIKEN stop
      AIDA on file R5_346

08:02 BigRIPS starts run 1038
      BRIKEN starts run 181114_0800_165Pm_053.dlt
      AIDA on file R5_346

      System wide checks ok * except nnaida 7 fails adc*
      FEE Temps ok - attachment 1
      Stats ok - attachment 2 
      Leakage currents ok - attachment 3

09:15 BigRIPS and BRIKEN stop
      AIDA on file R5_358

09:16 BigRIPS starts run 1039
      BRIKEN starts run 181114_0915_165Pm_054.dlt
      AIDA on file R5_358

10:15 BigRIPS and BRIKEN stop
      AIDA on file R5_368

10:15 BigRIPS starts run 1040
      BRIKEN starts run 181114_1015_165Pm_055.dlt
      AIDA on file R5_368

10:36 Analyser output of R5_368 - attachment 4

11:15 BugRIPS and BRIKEN stop
      AIDA on File R5_378

11:16 BigRIPS starts run 1041
      BRIKEN starts run
      AIDA on file R5_378



08.03 DAQ continues - AIDA file RIBF148/R5_384
      165Pm BigRIPS setting + 2.8mm Al degrader

      ASIC settings 2018Oct03-13.26.58
       from c. 09.00 13.11.18
       n+n FEE64s Ibias LF feedback 0xb -> 0xd
       HEC fast comparator threshold 0x20 -> 0xff
      
11.50 all system wide checks OK *except* nnaida7 fails ADC calibration

      detector biases & leakage currents OK - see attachments 5 & 6

      FEE64 temperatures OK - see attachment 7
      good event & AIDA discriminator statistics OK - see attachments 8

      Merger OK - see attachment 9
      TapeServer OK - see attachment 10
      no errors or warnings shown by server terminal sessions 

      per FEE64 Rate spectra - attachment 11
      per FEE64 HitRate spectraq - attachment 12
      1.8.L spectra - attachments 13-16
        some evidence of pulser peak shifts, notably nnaida5, 11 & 15
        nnaida1 pulser peak width 78 ch FWHM
      1.8.H spectra - attachments 17 & 18
 
      1.8.W spectra 20us FSR - attachments 19 & 23
      1.8.W spectra 200us FSR - attachments 20 & 24
      1.8.W spectra 2ms FSR - attachments 21 & 25
      1.8.W spectra 20ms FSR - attachments 22 & 26

12.15 BugRIPS and BRIKEN stop
      AIDA on File R5_388

12.16 BigRIPS starts run 1042
      BRIKEN starts run 57
      AIDA on file R5_388

12.22 *all* online and MIDASsort spectra zero'd

13:15 BigRIPS and BRIKEN stop
      AIDA on file R5_398

13:16 BigRIPS starts run 1043
      BRIKEN starts run58
      AIDA on file R5_398

13:28 BigRIPS and BRIKEN stop
      AIDA on file
      beam halted to give access to F11 area

13.44 beam started
      BigRIPS and BRIKEN start
      AIDA file RIBF148/R5_402
      BRIKEN run 59
      BigRIPS run 1043

14.45 BRIKEN and BigRIPS stop
      AIDA file RIBF148/R5_412

14.47 BRIKEN and BigRIPS start
      AIDA file RIBF148/R5_413
      BRIKEN run 60
      BigRIPS run 1044

15.43 BRIKEN and BigRIPS stop
      AIDA file RIBF148/R5_422

      BRIKEN Resets the timestamp

15:44 BRIKEN and BigRIPS start
      AIDA file RIBF148/R5_422
      BRIKEN run 61
      BigRIPS run 1045

16:02 System wide checks all ok *Except nnaida7 fails adc calibration*
      Leakage currents ok - attachment 27
      Stats ok - attachment 28
      FEE Temps ok - attachment 29

16:27 First 200ms of decay correlations in DSSD 3 and 4 for the 3 degrader settings - attachment 30
      DSSD 3 along the top row and DSSD 4 along the bottom.
      Dgrader settings are 3mm, 2.3mm and 2.8mm
      1 hour data in each
  781   Tue Nov 13 14:27:38 2018 LSWednesday 14 November 00:00 to 08:00
00:00 BRIKEN stop AIDA file RIBF148/R5_269 

---------------------------------------------------------------- 

00.02 BRIKEN start 
      BRIKEN file 45 
      BigRIPS file 1030 
      AIDA file RIBF148/R5_270 

00:07 system wide checks ok, except nnaida7 ADC calibration failure 
      FEE64 temperatures ok (attachment 1) 
      good event statistics ok (attachment 2) 
      detector bias/leakage currents ok (attachment 3) 

01:01 BRIKEN stop 
      AIDA file RIBF148/R5_279 

--------------------------------------------------------------- 

01.02 BRIKEN start 
      BRIKEN file 46 
      BigRIPS file 1031 
      AIDA file RIBF148/R5_279 

02:00 BRIKEN stop 
      AIDA file RIBF148/R5_289 

---------------------------------------------------------------- 

02.01 BRIKEN start 
      BRIKEN file 47 
      BigRIPS file 1032 
      AIDA file RIBF148/R5_289 

03:00 BRIKEN stop 
      AIDA file RIBF148/R5_298 

---------------------------------------------------------------- 

03.01 BRIKEN start 
      BRIKEN file 48 
      BigRIPS file 1033 
      AIDA file RIBF148/R5_298 

03:04 system wide checks ok, except nnaida7 ADC calibration failure 
      FEE64 temperatures ok (attachment 4) 
      good event statistics ok (attachment 5) 
      detector bias/leakage currents ok (attachment 6) 

04:00 BRIKEN stop 
      AIDA file RIBF148/R5_308 

----------------------------------------------------------------

04.03 BRIKEN start 
      BRIKEN file 49 
      BigRIPS file 1034 
      AIDA file RIBF148/R5_308 

05:00 BRIKEN stop 
      AIDA file RIBF148/R5_317 

---------------------------------------------------------------- 

05.01 BRIKEN start 
      BRIKEN file 50 
      BigRIPS file 1035 
      AIDA file RIBF148/R5_318 

06:00 BRIKEN stop 
      AIDA file RIBF148/R5_327 

---------------------------------------------------------------- 

06.02 BRIKEN start 
      BRIKEN file 51 
      BigRIPS file 1036
      AIDA file RIBF148/R5_327 

06:07 system wide checks ok, except nnaida7 ADC calibration failure 
      FEE64 temperatures ok (attachment 7) 
      good event statistics ok (attachment 8) 
      detector bias/leakage currents ok (attachment 9)

07:00 BRIKEN stop 
      AIDA file RIBF148/R5_337 

---------------------------------------------------------------- 

07.01 BRIKEN start 
      BRIKEN file 52 
      BigRIPS file 1037
      AIDA file RIBF148/R5_327 
  780   Tue Nov 13 07:35:37 2018 CA, TD, OHTuesday 13 November 16:00 - 00:00
16.36 DAQ continues ok
      AIDA file RIBF148/R5_198
      BRIKEN file 37
      BigRIPS file 1022

16.38 system wide checks ok, except nnaida7 ADC calibration failure

16.40 FEE64 temperatures ok (attachment 1)

16.42 good event statistics ok (attachment 2)

16.43 detector bias/leakage currents ok (attachment 3)

16.44 Merger and TapeServer ok, no error messages in terminals (attachments 4 and 5)

16.51 BRIKEN stop
      AIDA file RIBF148/R5_200

17.00 Al Degrader thickness changed from 2.3mm to 2.8mm
      The 2.3mm plate was previously assumed to be 2.5mm, but this has been corrected by measuring individual Al
      plates with digital micrometer.

17.02 BRIKEN start
      BRIKEN file 38
      BigRIPS file 1023
      AIDA file RIBF148/R5_202

18.01 BRIKEN stop
      AIDA file RIBF148/R5_211

18.03 BRIKEN start
      AIDA file RIBF148/R5_212
      BRIKEN file 39
      BigRIPS file 1024
 
18.08 system wide checks ok, except nnaida7 ADC calibration failure
      FEE64 temperatures ok (attachment 6)
      good event statistics ok (attachment 8)
      detector bias/leakage currents ok (attachment 7)

18.11 Merger and TapeServer ok, no error messages in terminal

19.00 BRIKEN stop
      AIDA file RIBF148/R5_221

19.02 BRIKEN start
      AIDA file RIBF148/R5_221
      BRIKEN file 40
      BigRIPS file 1025

19.57 system wide checks ok, except nnaida7 ADC calibration failure
      FEE64 temperatures ok (attachment 9)
      good event statistics ok (attachment 10)
      detector bias/leakage current ok (attachment 11)

20.01 BRIKEN stop
      AIDA file RIBF148/R5_231

20.03 BRIKEN start
      AIDA file RIBF148/R5_231
      BRIKEN file 41
      BigRIPS file 1026

21.01 BRIKEN stop
      AIDA file RIBF148/R5_240

21.03 BRIKEN start
      AIDA file RIBF148/R5_240
      BRIKEN file 42
      BigRIPS file 1027
      
21:18 system wide checks ok - except nnaida7 ADC calibration failure
      FEE64 temperatures ok (attachment 12)
      good event statistics ok (attachment 13)
      detector bias/leakage current ok (attachment 14)

22:01 BRIKEN stop
      AIDA file RIBF148/R5_250

22:03 BRIKEN start
      AIDA file RIBF148/R5_250
      BRIKEN file 43
      BigRIPS file 1028

22:10 system wide checks ok - except nnaida7 ADC calibration failure
      FEE64 temperatures ok (attachment 15)
      good event statistics ok (attachment 16)
      detector bias/leakage current ok (attachment 17)
      Merger and TapeServer ok, no error messages in terminal

23:01 BRIKEN stop
      AIDA file RIBF148/R5_260

23:03 BRIKEN start
      AIDA file RIBF148/R5_260
      BRIKEN file 44
      BigRIPS file 1029

23.05 system wide checks ok - except nnaida7 ADC calibration failure
      FEE64 temperatures ok (attachment 18)
      good event statistics ok (attachment 20)
      detector bias/leakage current ok (attachment 19)
      Merger and TapeServer ok, no error messages in terminal





      

      
      
  779   Tue Nov 13 01:41:12 2018 TDOffline analysis RIBF148/R5_130 to _139
10.41 FEE64 ADC data synchronised - attachment 1 

LEC & HEC rates

 *** DSSSD # 1 count:   5472516 old count:   5429034 dt:      1.05 s  LEC rate:  41240.10 Hz
 *** DSSSD # 2 count:   8599335 old count:   8530134 dt:      1.05 s  LEC rate:  65633.05 Hz
 *** DSSSD # 3 count:   1647116 old count:   1632316 dt:      1.05 s  LEC rate:  14036.92 Hz
 *** DSSSD # 4 count:   1825652 old count:   1810910 dt:      1.05 s  LEC rate:  13981.91 Hz
 *** DSSSD # 5 count:    384243 old count:    380911 dt:      1.05 s  LEC rate:   3160.20 Hz
 *** DSSSD # 6 count:   1246549 old count:   1236520 dt:      1.05 s  LEC rate:   9511.91 Hz
 *** DSSSD # 1 count:        31 old count:        30 dt:      1.05 s  HEC rate:      0.95 Hz
 *** DSSSD # 2 count:       258 old count:       255 dt:      1.05 s  HEC rate:      2.85 Hz
 *** DSSSD # 3 count:      1564 old count:      1548 dt:      1.05 s  HEC rate:     15.18 Hz
 *** DSSSD # 4 count:      3547 old count:      3512 dt:      1.05 s  HEC rate:     33.20 Hz
 *** DSSSD # 5 count:       680 old count:       676 dt:      1.05 s  HEC rate:      3.79 Hz
 *** DSSSD # 6 count:     10708 old count:     10629 dt:      1.05 s  HEC rate:     74.93 Hz

Total heavy ion rate c. 130Hz of which c. 50% stop in DSSSDs # 1-6

Attachment 1 - *total* implant energy for AIDA DSSSD stack (5.6MeV/channel)
               ch 1571 ~ 8.8GeV, ch 244 ~ 1.4GeV

Attachment 2 - implant energy for stopping DSSSD layer (20MeV/channel)
               ch 390 ~ 7.8GeV
  778   Mon Nov 12 23:03:53 2018 TDTuesday 13 November 08:00 - 16:00
08.03 DAQ continues - AIDA file RIBF148/R5_117
      165Pm BigRIPS setting + 3mm Al degrader
      
08.10 all system wide checks OK *except* nnaida7 fails ADC calibration

      detector biases & leakage currents OK - see attachments 1 & 2

      FEE64 temperatures OK - see attachment 3
      good event & AIDA discriminator statistics OK - see attachments 4 & 5

      Merger OK - see attachment 6
      TapeServer OK - see attachment 7
      no errors or warnings shown by server terminal sessions 

08.16 analysis of file RIBF148/R5_116 - see attachment 8
      max deadtime nnaida19 ~ 1/420 ~ 0.25%, no timewarps

08.20 BRIKEN stop file
      AIDA file RIBF148/R5_119

08.22 BRIKEN start file
      AIDA file RIBF148/R5_120
      BRIKEN file 28
      BigRIPS file 1013

08.44 MIDASsort online spectra zero'd

08.56 1.8.W spectra 20ms FSR - see attachments 16 & 17
      observe slow transient recovery per 33nF a.c. coupling but 'sawtooth' transients appear to be absent/rare

09.25 BRIKEN stop file
      AIDA file RIBF148/R5_129

09.28 BRIKEN start file
      AIDA file RIBF148/R5_130
      BRIKEN file 29
      BigRIPS file 1014

10.09 per FEE64 hit pattern (rate) - see attachment 9
      per FEE64 1.8.L spectra - see attachments 10-13
       nnaida1 pulser peak width 76 ch FWHM
      per FEE64 1.8.H spectra - see attachments 14 & 15

10.25 BRIKEN stop file
      AIDA file RIBF148/R5_139

10.27 Beam off - enter F11 to change BRIKEN amp gain
      Correlation scaler pulser trigger frequency changed from 100Hz to 10Hz to minimise BigRIPS DAQ deadtime
      Note - we will observe both edges of pulser trigger doubling the apparent frequency and the TDR data format
      analyser reports each 16-bit word of the 48-bit correlation scaler so weill observe 6x frequency or 600Hz
(previously)
      or 60Hz (now). 

10.37 BRIKEN start file
      AIDA file RIBF148/R5_141
      BRIKEN file 30
      BigRIPS file 1015 

10.25 BRIKEN stop file
      AIDA file RIBF148/R5_144

      BRIKEN reloading DAQ configuration, will send correlation scaler reset

10.56 BRIKEN start file
      AIDA file RIBF148/R5_145
      BRIKEN file 31
      BigRIPS file 1016

      BRIKEN reload DAQ configuration again

11.00 BRIKEN stop file
      AIDA file RIBF148/R5_145

11.06 BRIKEN start file
      AIDA file RIBF148/R5_145
      BRIKEN file 32
      BigRIPS file 1017

11.50 system wide checks ok, except nnaida7 ADC calibration failure
      FEE64 temperatures ok (attachment 18)
      good event statistics ok (attachment 19)
      detector bias/leakage currents ok (attachment 20)

12.05 BRIKEN stop file
      AIDA file RIBF148/R5_155

12.07 BRIKEN start file
      BRIKEN file 33
      BigRIPS file 1018
      AIDA file RIBF148/R5_155

13.06 BRIKEN stop file
      AIDA file RIBF148/R5_165

13.08 BRIKEN start file
      BRIKEN file 34
      BigRIPS file 1019
      AIDA file RIBF148/R5_165

13.35 BRIKEN stop file
      AIDA file RIBF148/R5_169

BighRIPS DAQ reset required

13.38 BRIKEN start file
      BRIKEN file 35
      BigRIPS file 1020
      AIDA file RIBF148/R5_170

14.39 BRIKEN stop file
      AIDA file RIBF148/R5_179

14.40 BRIKEN start file
      BRIKEN file 36
      BigRIPS file 1021
      AIDA file RIBF148/R5_179

15.38 BRIKEN stop file
      AIDA file RIBF148/R5_189

15.49 System wide checks ok - except nnaida7 ADC calibration failure
      FEE64 temperatures ok - attachment 21
      good event statistics ok - attachment 22
      detector bias/leakage currents ok - attachment 23

15.51 BRIKEN start file
      BRIKEN file 37
      BigRIPS file 1022
      AIDA file RIBF148/R5_191

      
  777   Mon Nov 12 14:51:44 2018 OHTuesday 13 November 00:00 - 08:00
00:00 AIDA currently on file R5_38
      BRIKEN on file 181112_2321_165Pm_019.dlt (AIDA file at start R5_33)
      BigRIPS run 1004



00:23 BRIKEN stop file
      AIDA Currently on file R5_43
      
00:26 BRIKEN start 181113_0025_165Pm_020.dlt 
      BigRIIPS start 1005
      AIDA Currently on file R5_43

     System wide checks ok

01:13 Bias and leakage currents ok - attchment 1
      Stats ok - attachment 2
      FEE Temps ok - attachment 3

01:21 BigRIPS and BRIKEN stop
      AIDA on file R5_52

01:25 BigRIPS starts run 1006
      BRIKEN starts run 181113_0123_165Pm_021.dlt
      AIDA on file R5_53

02:21 BigRIPS and BRIKEN stop
      AIDA on file R5_62

02:23 BigRIPS starts run 1007
      BRIKEN starts run 181113_0222_165Pm_022.dlt
      AIDA on file R5_62

      ASIC load check ok

03:15 Beam dropped out unsure for how long but is now back

03:21 BigRIPS and BRIKEN stopped
      AiDA on file R5_71
      
03:23 BigRIPS starts run 1008
      BRIKEN starts run 181113_0320_165Pm_023.dlt
      AIDA on file R5_71

03:45 Output of analyser on R5_70 - attachment 4

03:59 System wide checks ok
      FEE Temps ok - attachment 5
      Statistics ok - attachment 6


04:21 BigRIPS and BRIKEN stop
      AIDA on file R5_81

04:23 BigRIPS starts run 1009
      BRIKEN starts run 181113_0421_165Pm_024.dlt
      AIdA on file R5_81

05:19 BigRIPS and BRIKEN stop
      AIDA on file R5_90

05:20 BigRIPS start run 1010
      BRIKEN starts run 181113_0520_165Pm_025.dlt
      AIDA on file R5_90

05:49 System wide checks all ok
      Stats ok - attachment 7
      FEE Temps ok - attchment 8
      Bias and leakage currents ok - attachment 9

      High energy hit pattern per dssd - attachment 10
      Low energy Ex vs Ey plot per dssd - attachment 11
      High energy Ex vs Ey plot per dssd - attachment 12
      Also using the previously merged files produced from Phong's sort have confirmed that there is no to
      little punch through on DSSD3
      Did this through the use of a 2d plot of energy DSSD 3 vs the velocity

06:21 BigRIPS and BRIKEN stop
      AIDA on file R5_100

06:23 BigRIPS starts run 1011
      BRIKEN starts run 181113_0622_165Pm_026.dlt
      AIDA on file R5_100

07:19 BigRIPS and BRIKEN stop
      AIDA on file R5_110

07:20 BigRIPS starts run 1012
      BRIKEN starts run
      AIDA on file R5_110 
  776   Mon Nov 12 08:59:43 2018 LS, CA, TDMonday 12 November 6pm onwards

17:59 DAQ continues OK
      Stats OK - attachment 1
      FEE temperatures OK - attachment 2
      Bias and leakage currents OK - attachment 3
      System-wide checks OK *except* nnaida7 fails ADC calibration


19:07 DAQ continues OK
      Stats OK - attachment 4
      FEE temperatures OK - attachment 5
      Bias and leakage currents OK - attachment 6
      System-wide checks OK *except* nnaida7 fails ADC calibration

20.19 DAQ starts
      AIDA file RIBF148/R5_4
      BRIKEN file 16
      BigRIPS 1001

      165Pm setting + 3mm Al degrader

20.21 all online & MIDASsort histograms zero'd

20.23 FEE64 good event statistics - see attachment 7
      Merger - see attachment 8
      TapeServer - see attachment 9

      HEC x versus y spectra - see attachment 10
       SN thinks DSSSD #3 are the ions of interest, #4 are the ions of interest at different charge state
       and #5 & #6 are lighter ions which do not stop in DSSSD #1-6

21.21 DAQ stops 

      DAQ starts
      AIDA file RIBF148/R5_14
      BRIKEN file 18
      BigRIPS 1003

21.26 HEC x vs y multiplicity spectra - attachment 11

21.29 HEC Ex vs Ey spectra - attachment 12
      FEE64 rate spectra - attachment 13

21.31 1.8.L front/rear energy spectra (attachments 14/15) LEC

21.33 1.8.H front/rear energy spectra (attachments 16/17) HEC

21.46 system wide checks ok, except nnaida7 ADC calibration failure
      FEE64 good event statistics ok (attachment 18)
      FEE64 temperatures ok (attachment 19)
      Leakage currents/detector bias ok (attachment 20)

21.49 Merger and TapeServer ok, no error messages in terminal
      DAQ still running (RIBF148/R5_18)

22.10 attachment 21 - pulser spectra in all channels fired at same time
                    - FEE64 in sync

22.12 SYNC100 at 9153.8 Hz
      FEE64 discriminator at ~15000 Hz - higher than expected
      ~1 second deadtime in FEE19 - due to nnaida12 running fast
      no timewarps observed in FEE64
      all of above in attachment 22
   
22:32 DAQ continues OK
      Stats OK - attachment 24
      FEE temperatures OK - attachment 23
      Bias and leakage currents OK - attachment 25
      System-wide checks OK *except* nnaida7 fails ADC calibration   

23:30 DAQ continues OK
      Stats OK - attachment 26
      FEE temperatures OK - attachment 27
      Bias and leakage currents OK - attachment 28
      System-wide checks OK *except* nnaida7 fails ADC calibration 
      
  775   Sun Nov 11 21:35:42 2018 CB, OH, CA, LSMonday 12 November
06:35 DAQ Continues ok
      Stats ok - attachment 1
      FEE Temps ok - attachment 2
      Bias and leakage currents ok - attachment 3
      System wide checks all ok
      Chiller refilled

07:57 DAQ continues OK
      Stats OK - attachment 4
      FEE temperatures OK - attachment 5
      Bias and leakage currents OK - attachment 6
      System-wide checks OK *except* nnaida7 fails ADC calibration

10:06 DAQ continues OK
      Stats OK - attachment 7
      FEE temperatures OK - attachment 8
      Bias and leakage currents OK - attachment 9
      System-wide checks OK *except* nnaida7 fails ADC calibration
      Workstation occasionally feels sluggish. See iostat 5 (attach 10) & top -a (attach 11)

12:08 DAQ continues OK
      Stats OK - attachment 12
      FEE temperatures OK - attachment 13
      Bias and leakage currents OK - attachment 14
      System-wide checks OK *except* nnaida7 fails ADC calibration
      

15:40 DAQ continues OK
      Stats OK - attachment 15
      FEE temperatures OK - attachment 16
      Bias and leakage currents OK - attachment 17
      System-wide checks OK *except* nnaida7 fails ADC calibration


16:58 DAQ continues OK
      Stats OK - attachment 18
      FEE temperatures OK - attachment 19
      Bias and leakage currents OK - attachment 20
      System-wide checks OK *except* nnaida7 fails ADC calibration
  774   Sat Nov 10 21:53:29 2018 CA, CB, TD, OHSunday 11 November
06.53 DAQ continues OK - data transfer disabled

06.55 all system wide checks OK *except* nnaida7 fails ADC calibration
      detector biases & leakage currents OK - see attachments 1 & 2
      Julabo FL11006 chiller set point +20 deg C actual +20 deg C, water level c. 75% (L-H)
      ambient tempature + 26.9 deg C, RH 21.6%, d.p. +2.9 deg C

      FEE64 temperatures OK - see attachment 3
      good event statistics OK - see attachment 4

      per FEE64 rate spectra - see attachment 5
      ASIC check load
      per FEE64 rate spectra - see attachment 6
      good event statistics OK - see attachment 7

      1.8.L spectra - see attachments 8 & 9
       nnaida1 pulser peak width 72 ch FWHM

      1.8.W spectra 20us FSR - see attachments 10 & 14
      1.8.W spectra 200us FSR - see attachments 11 & 15
      1.8.W spectra 2ms FSR - see attachments 12 & 16
      1.8.W spectra 20ms FSR - see attachments 13 & 17
      Note - LED threshold 9000 for *all* FEE64s

07.27 statistics zero'd
      some 32bit counters (e.g. nnaida19 & nnaida20) had overflowed/wrapped around

18:19 Computer appears to be running slow though cannot see a reason why.
      No programs using to much ram or cpu
      FEE temp ok - attachment 18
      bias and leakage currents ok - attachment 19
      System wide checks ok

21:02 System wide checks ok
      DAQ Continues ok - data transfer disabled.
      Bias and leakage currents ok - attachment 20
      FEE Temperatures ok - attachment 21
  773   Sat Nov 10 04:06:20 2018 TDLess commonly recorded AIDA control tabs
Some less commonly recorded AIDA control tabs whilst DAQ going (data transfer disabled)
  772   Sat Nov 10 03:50:00 2018 CA, CB, TD, OHSaturday 10 November
12.35 DAQ continues OK - data transfer disabled

12.37 all system wide checks OK *except* nnaida7 fails ADC calibration
      detector biases & leakage currents OK - see attachments 1 & 2
      Julabo FL11006 chiller set point +20 deg C actual +20 deg C, water level topped up c. 1 litre - 80% (L-H)
      ambient tempature + 27.3 deg C, RH 33.0%, d.p. +9.6 deg C

      FEE64 temperatures OK - see attachment 3
      good event statistics OK - see attachment 4

      per FEE64 rate spectra - see attachment 5

      1.8.L spectra - see attachments 6 & 7
       nnaida1 pulser peak width 71 ch FWHM

      1.8.W spectra 20us FSR - see attachments 8 & 9
  771   Fri Nov 9 02:26:58 2018 TDOffline analysis R18, R27, R29 - alpha background
Offline analysis of Oct18/R18_0 to 2, R27_0, 4 & 9, R29_0, 7 & 30

alpha background, BNC PB-4 pulser OFF, LEC/MEC slow comparator 0x64 (~1MeV)

*** ENTRY finish

 *** data items: 2043072278 ( 246610.11 Hz)
 *** ADC events:   10666744 (   1287.53 Hz)
 *** time warps:          2 (      0.00 Hz)
 *** DSSSD # 1 count:      1446 old count:      1446 dt: 231900.06 s  LEC rate:      0.01 Hz
 *** DSSSD # 2 count:       568 old count:       568 dt: 231900.06 s  LEC rate:      0.00 Hz
 *** DSSSD # 3 count:       644 old count:       644 dt: 231900.06 s  LEC rate:      0.00 Hz
 *** DSSSD # 4 count:       612 old count:       612 dt: 231900.06 s  LEC rate:      0.00 Hz
 *** DSSSD # 5 count:       591 old count:       591 dt: 231900.06 s  LEC rate:      0.00 Hz
 *** DSSSD # 6 count:       796 old count:       796 dt: 231900.06 s  LEC rate:      0.00 Hz
 *** DSSSD # 1 count:         6 old count:         6 dt: 231900.06 s  HEC rate:      0.00 Hz
 *** DSSSD # 2 count:         3 old count:         3 dt: 231900.06 s  HEC rate:      0.00 Hz
 *** DSSSD # 3 count:         0 old count:         0 dt: 231900.06 s  HEC rate:      0.00 Hz
 *** DSSSD # 4 count:         1 old count:         1 dt: 231900.06 s  HEC rate:      0.00 Hz
 *** DSSSD # 5 count:         0 old count:         0 dt: 231900.06 s  HEC rate:      0.00 Hz
 *** DSSSD # 6 count:         1 old count:         1 dt: 231900.06 s  HEC rate:      0.00 Hz

 *** ENTRY finish ends

attachment 1 - per DSSSD m_p versus m_n
           2 - per DSSSD x versus y
           3 - per DSSSD E_p versus E_n
           4 - DSSSD channel versus E_p
           5 - DSSSD channel versus E_p (expanded)
           6 - hit pattern (ASIC & DSSSD order)
           7 - titles
           8 - variables 
               N.B. ADC offsets not set, 0 by default
                    | E_p - E_n | < 2000


DSSSD configuration looks OK. Conclude problems identified and addressed November 5 are confirmed
as fixed - see https://elog.ph.ed.ac.uk/AIDA/766 and https://elog.ph.ed.ac.uk/AIDA/761
  770   Thu Nov 8 23:35:50 2018 OH, TD, CA, CBFriday 9 November
08:36 DAQ still running
      Not writing data to disk

      Bias and leakage currents ok - attachment 1
      System wide checks all ok
      FEE Temperatures ok - attachment 2
      Statistics - attachment 3
      Check ASIC Control done

08:56 Pulser peaks are ok and similar to what has been observed over the past two weeks
      Layout 4 and 5 - attachments 4 and 5

11.55 Lost connection to FEE64 1-16 - fuse blown
      stopped DAQ
      switched all FEE64 off
      Replaced 20A fuse
      switched FEE64 back on individually
      system wide checks ok, except nnaida7 failure in ADC calibration
      DAQ start (not writing to file)
      FEE64 temperatures ok (attachment 6)
      Bias/Leakage currents ok (attachment 7)
      good event statistics ok (attachment 8)

17.08 all system wide checks OK *except* nnaida7 fails ADC calibration
      detector biases & leakage currents OK - see attachments 9 & 10

      FEE64 temperatures OK - see attachment 11
      good event statistics OK - see attachment 12

      per FEE64 rate spectra - see attcahment 13

      1.8.L spectra - see attachments 14 & 15
       nnaida1 pulser peak width 72 ch FWHM

      1.8.W spectra 20us FSR - see attachments 16 & 20
      1.8.W spectra 200us FSR - see attachments 17 & 21
      1.8.W spectra 2ms FSR - see attachments 18 & 22
      1.8.W spectra 20ms FSR - see attachments 19 & 23
  769   Thu Nov 8 00:55:18 2018 CA, CB, TD, OHThursday 8th November
09.57 DAQ still running (R29_29)
      System wide checks ok, except nnaida7 ADC calibration failure
      
09.59 FEE64 temperatures ok (attachment 1)
      TapeServer ok
      Link16 error reported in Merger (attachment 2)

10.04 Bias/Leakage currents ok (attachment 3)

10.07 Good event statistics ok, except nnaida17, 18, 22 which appears to intermittently run fast overnight, and
      nnaida2 which runs fast due to hot channel (attachment 4)

10.11 1.8.W spectrum (attachment 5)

10.56 2.15.H spectra - show hot high energy channel in nnaida2 (attachment 6)

11.09 attachments 7,8,9 - High energy channels spectra, show hot channel in nnaida17 

11.45 Stats - Attachment 10 


15.07 analysis RIBF/R1_1 - see attachment 11
      <1% deadtime for high rate FEE64s nnaida19 & nnaida20

15.14 AIDA shield (c. 3" Pb) in position between F11 and upstream BRIKEN (CH2)n shield - checked by TD & GK
      Julabo FL11006 chiller set point +20 deg C actual +20.0 deg C, water added to 80% level (L-H) or 2/3 (M-H) 

16:41 DAQ stopped
      slow comparator threshold at 10
      DAQ restarted (\RIBF148\R2)
      DAQ stopped (\RIBF148\R2_3)
      slow comparator threshold raised back to 100
      DAQ start (\RIBF148\R3_0)
17.10 DAQ stop (\RIBF148\R3_0)
      slow comparator threshold lowered back to 10
      DAQ start (not writing to file)
      good event statistics ok (attachment 12)

17.15 system wide checks ok
      FEE64 temperatures ok (attachment 13)
      bias/leakage currents ok (attachment 14)

18:35 R4_0 started for background measurement for Phong.
      R4_0 should be discarded as FEE1 was running fast at start. recovered with ASIC check

18:51 R1_2 stopped
  768   Wed Nov 7 01:00:58 2018 CA, CB, TD, OH, PJWWednesday 7 November
10.02 DAQ still running, on file Oct18/R27_9
      Merger and TapeServer ok, no error warnings in terminals

10.07 Good event statistics ok, except nnaida6 rate being high (attachment 1)
      nnaida17 rate ok, but counts very high. May have run fast at some point overnight.
      System wide checks ok, except nnaida7 failure in ADC calibration
      FEE64 temperatures ok (attachment 2)

10.13 Bias/leakage currents slightly higher, but ok (attachment 3)

10:30 1.8.W spectra (attachment 4)

11.10 Stopped the DAQ (R27_9)
      Checked ASIC control - ok
      Started the DAQ again (Oct18/R28_0)
      good event statistics ok, aside from nnaida6 running slightly fast (attachment 5)

15.07 DAQ stop - file Oct18/R28_2

      Detector bias OFF 

      Move AIDA downstream to check position of Clover G7 

16.05 Move back upstream into BRIKEN (CH2)n moderator assembly

      Detector bias ON

16.12 all system wide checks OK *except* nnaida7 fails ADC calibration
      sync all ASIC clocks using ReSYNC
      detector biases & leakage currents OK - see attachments 6 & 7
      FEE64 temperatures OK - see attachment 8
      good event statistics OK *except* nnaida2 - see attachment 9
                                                  see attachment 10 for comparison to statistics 5.1.18

16.41 1.8.W spectra 20us FSR - see attachments 11 & 12

16.55 slow comparator thresholds raised from 10 to 100
      DAQ start (Oct18/R29_0)
      Merger and TapeServer ok - no error warnings in terminals
      good event statistics ok, except nnaida6 running fast (attachment 13)




      
  767   Tue Nov 6 00:13:00 2018 CB. PJW, TD, OH, CATuesday 6 November
09:13 DAQ still running R18_1
      Merger and TapeServer OK
      System wide checks ok, except for nnaida7 ADC calibration failure
      Temperature OK (attachment 1)
      Bias and leakage current OK (attachment 2)
      Good event statistics OK (attachment 3)
      
11.20 1.8.W spectra - attachment 4 & 5

      analysis file Oct18/R18_1 - attachment 6


15:35 Inserted AIDA snout in BRIKEN. Lowered threshold to 100 keV. Rate looks OK.
      R19 pulser walkthrough 90 0000 ... 10 0000 (10 000 steps) - attach 7&8
      R21 pulser walkthrough 12 000 ... 2 000 (2 000 steps)
      Pulser back to 90 000. Frequency set to zero.
      R22 background run starts. 
      Rates OK (attach 9)

16.07 Raised slow comparator threshold to 100 from 10
      DAQ start (file R23)
      Merger and TapeServer ok, no error messages in terminal
      Good event statistics ok (attachment 10)
      System wide checks ok, except nnaida7 failing ADC calibration 
      FEE64 temperatures ok (attachment 11)
      bias/leakage currents ok (attachment 12)

16.58 Repeat pulser walkthroughs with additional ASIC check loads

      R25 pulser walkthrough 90 0000 ... 10 0000 (10 000 steps) - attach 7&8
      R26 pulser walkthrough 12 000 ... 2 000 (2 000 steps)


18.26 DAQ start - file Oct18/R27
      alpha background
      LEC/MEC slow comparator 0xa -> 0x64
      BNC PB-4 pulser OFF @ 18.29!

18.34 1.8.W spectra 20us FSR - see attachments 13 & 14
  766   Mon Nov 5 10:02:52 2018 TDOffline analysis R16 - beam background
Offline analysis of Oct18/R16_0 to 11


BNC PB-4 pulser OFF, LEC/MEC slow comparator 0x64 (~1MeV)
background (presumably high energy, low Z particles) from beam stopping in F11 E detector upstream 
of AIDA and BRIKEN - ~10-15cm Pb shielding installed in BRIKEN to stop heavy opns reaching AIDA

*** ENTRY finish

 *** data items: ********** ( -13850.89 Hz)
 *** ADC events: 2089104652 (  24903.76 Hz)
 *** time warps:          0 (      0.00 Hz)
 *** DSSSD # 1 count:     81173 old count:     81171 dt: 106837.14 s  LEC rate:      0.76 Hz
 *** DSSSD # 2 count:     73671 old count:     73668 dt: 106837.14 s  LEC rate:      0.69 Hz
 *** DSSSD # 3 count:     74114 old count:     74109 dt: 106837.14 s  LEC rate:      0.69 Hz
 *** DSSSD # 4 count:     73324 old count:     73320 dt: 106837.14 s  LEC rate:      0.69 Hz
 *** DSSSD # 5 count:     74312 old count:     74308 dt: 106837.14 s  LEC rate:      0.70 Hz
 *** DSSSD # 6 count:     74653 old count:     74649 dt: 106837.14 s  LEC rate:      0.70 Hz
 *** DSSSD # 1 count:         0 old count:         0 dt: 106837.14 s  HEC rate:      0.00 Hz
 *** DSSSD # 2 count:         0 old count:         0 dt: 106837.14 s  HEC rate:      0.00 Hz
 *** DSSSD # 3 count:         0 old count:         0 dt: 106837.14 s  HEC rate:      0.00 Hz
 *** DSSSD # 4 count:         0 old count:         0 dt: 106837.14 s  HEC rate:      0.00 Hz
 *** DSSSD # 5 count:         0 old count:         0 dt: 106837.14 s  HEC rate:      0.00 Hz
 *** DSSSD # 6 count:         0 old count:         0 dt: 106837.14 s  HEC rate:      0.00 Hz

 *** ENTRY finish ends


attachment 1 - per DSSSD m_p versus m_n
           2 - per DSSSD x versus y
           3 - per DSSSD E_p versus E_n
           4 - DSSSD hit pattern (ASIC & DSSSD order) expanded view of LEC events

DSSSD configuration looks OK. With improved statistics (cf alpha background) some missing strips identifiable
- see also Elog https://elog.ph.ed.ac.uk/AIDA/764
  765   Mon Nov 5 01:40:10 2018 CA, CB, TD, OH, PJWMonday 5 November
10.40 Lowered slow comparator threshold from 100 to 10
      Good event statistics ok (attachment 1)
      System wide checks ok, except for nnaida7 ADC calibration failure
      FEE64 temperatures ok (attachment 2)
      Bias/Leakage currents ok (attachment 3)
      1.0.L spectra obtained, look ok (attachment 4)
      DAQ stopped (R16)
 
10.49 Slow comparator threshold raised from 10 to 100
      DAQ restarted (R17)
      Merger and TapeServer ok, no error messages in terminals
      Good event statistics ok (attachment 5)
      nnaida2 is now at a good rate, after fixing kapton connection.

15:09 DAQ still running (Oct18/R17_0)
      Merger and TapeServer ok
      System wide checks ok, except for nnaida7 ADC calibration failure
      FEE64 temperatures ok (attachment 6)
      Bias/Leakage currents ok (attachment 7)
      Good event statistics ok (attachment 8)


18.48 good event statistics OK *except* nnaida17 c. 400k
      ASIC Control -> Check ASIC Control
      *all* FEE64 good events statistics now OK
      DAQ stop - current file Oct18/R17_20

18.50 DAQ start - file Oct18/R18
      BNC PB-4 OFF
      LEC/MEC slow comparator 0x64

      alpha background run

18.54 all system wide checks OK *except* nnaida7 fails ADC calibration

      detector biases & leakage currents OK - see attachments 9 & 10
      FEE64 temperatures OK - see attachment 11
      good event statistics OK - see attachment 12
      Merger - Link16 errors reported - see attachment 13
      TapeServer OK - see attachment 14

      1.8.W spectra - attachment 15 & 16


      