Sun Apr 6 14:21:53 2025, TD, [How To] Startup CARME
|
- water flow/interlock checks
check water flow to/from inflow/outflow manifolds
|
Sat Feb 3 15:05:10 2024, CB, TD, [How To] Restart Anydesk
|
1. Check Proxy server is correct
localhost : 8080
incoming connections 7070 |
Tue May 27 08:38:29 2025, TD, [How To] Recover DAQ when one FEE64 stops sending data - short(er) version
|
1) Select 'No Storage' [workspace 4, display 1, browser tab 'TapeServer']
If already in 'No Storage' mode please ignore this step
|
Tue Jun 4 19:19:26 2024, TD, [How To] Recover DAQ when one FEE64 stops sending data
|
1) STOP DAQ [workspace 2, display 1, browser tab 'Run Control']
all FEE64s should change status from 'going' to 'stopped' *except* whichever FEE64(s) have a problem - typically their status is 'going' or 'error'
|
Sat Jun 8 17:46:12 2024, TD, [How To] Cycle Left DSSSDs
|
Interactive Motion Program [workspace 6, display 2]
|
Fri Jun 14 14:48:02 2024, CB NP ML, [How To] Change target pressure. EMERGENCY ONLY! 
|
ONLY FOLLOW THESE INSTRUCTIONS if E1 turbo is below 820 Hz, pressure in E1 is above 2.5E-1 mbar and experts (Nikos, Andreas) cannot be reached.
Go to the red cabinet under the stairs. |
Wed Nov 10 14:41:12 2021, TD RSS + CB (remotely), Wrapping CARME in heating tape
|
ML reports that baking of the upstream section (gas jet interaction chamber plus e-target) has commenced - initially to 50 deg C to check thermocouples.
If OK baking
temperature will be ramped slowly (which I think means c. 10 deg C per h) to limits established for specific components by the e-target.
|
Sun Oct 31 07:41:20 2021, CB JM + RSS, Wires plugged in DSSDs 8x
|
(Wed 27 October)
Started with top-most flange. Attemptedto plug in MACOR lead in DSSD plug in preparation for jacking in. Realised that extender plate thickness
causes plug to be rasied with respect to nominal position, which results in plug non entering straight. Removed extension plate. |
Tue Aug 18 11:26:26 2020, JM, Week ending Friday 14/08/20
|
Week ending friday 14/08/20
CARME chamber securely mounted upon aluminium frame and support skis. Neg-ion pumps and right angled flanges installed. Neg pumps installed in
the wall detector section of the chamber. Neg pumps continuity checked and are electically isolated from the chamber. |
Wed Apr 9 02:40:04 2025, TD, Wednesday 9 April 11x
|
03.37 DAQ continues
Data file APR25/R5_8
|
Wed Mar 6 10:47:11 2024, JG, TD, Wednesday 6 March - PEXARIA5 WR test   
|
Courtesy Nik Kurz, JG has installed a PEXARIA5 PCIe card adjacent to CARME - BuTIS single-mode fibre input
and HDMI output to root MACB input for distribution to the other MACBs and FEE64s.
|
Wed Nov 30 08:52:59 2022, AR TD, Wednesday 30 November 26x
|
9:40
DSSD bias and leakage current values:
-99.99 V |
Wed Oct 28 10:41:57 2020, TD, Wednesday 28 October 6x
|
10.32
|
Wed Sep 27 15:56:41 2023, TD, Wednesday 27 September  
|
16.55 CARME IE514 8.2e-11 mbar
|
Wed Nov 25 10:39:37 2020, TD, Wednesday 25 November 7x
|
10.39
|
Wed Apr 24 12:48:35 2024, TD, Wednesday 24 April 21x
|
Replace AIDA ASIC mezzanine of aida01
|
Wed Sep 23 13:34:32 2020, JM, TD, Wednesday 23 September    
|
Connected Leybold Ionivac IE514 to Leybold Combivac CM52 Vacuum Gauge Controller
|
Wed Feb 23 18:58:12 2022, TD CN, Wednesday 23 February 15.00-23.00 shift 6x
|
Assorted screenshots of the CARME, CRYRING and gas jet target control systems in operation
|
Wed Jan 17 19:15:47 2024, TD, Wednesday 17 January
|
CAEN N1419ET remote control via carme-gsi and nnrpi1 - see https://elog.ph.ed.ac.uk/CARME/472
|
Wed Aug 11 12:30:40 2021, TD RSS, Wednesday 11 August 8x
|
Attachments 1 & 2 - 2x SAES D-2000 re-fitted to side ports
all 4x SAES D-2000 now re-fitted to chamber
|