  3   Tue Aug 18 17:35:20 2020 TDSAES UHV1400 pin assignment
Using a digital multimeter confirmed continuity for SAES-supplied 
power cable (Amphenol (circular) 6-pin plug to Han 05 plug) for
the following pins

pin A - pin 5
pin F - pin 3

which correspond to the type K chromel/alumel thermocouple contacts
and Neg PSU output connector pins for the thermocouple (e.g. see p.34
of Neg PSU manual).
Attachment 1: NEG_POWER_user_manual.pdf
NEG_POWER_user_manual.pdf NEG_POWER_user_manual.pdf NEG_POWER_user_manual.pdf NEG_POWER_user_manual.pdf NEG_POWER_user_manual.pdf NEG_POWER_user_manual.pdf NEG_POWER_user_manual.pdf NEG_POWER_user_manual.pdf
Attachment 2: 20200813_121944_(1).jpg
20200813_121944_(1).jpg
Attachment 3: 20200813_134548.jpg
20200813_134548.jpg
Attachment 4: RFKIT9904220_(2).pdf
RFKIT9904220_(2).pdf
Attachment 5: RFKIT9905220_(2).pdf
RFKIT9905220_(2).pdf
  28   Thu Oct 22 10:39:40 2020 TDThursday 22 October
10.40

CARME chamber 2.84e-08mbar
Backing 1.2e-7mbar (Edwards vacuum cart w/RGA)

CARME temps - see attachment 1
vessel 146.62 deg C max diff 21.42 deg C
octagon 27.85 deg C max diff 6.35

SAES HV power modules - see attachments 2-12

14.00

CARME chamber 2.78e-08mbar

Start 4x SAES D2000-10 *NEG* pumps (ion pump OFF) - see attachments 13-18

Ramp 45 mins
Hold 60 mins
225W/550deg C

NEG pumps report temps c. 130 deg C

14.15 ramp

CARME chamber 2.0e-07mbar
Backing 3.3e-07mbar (Edwards vacuum cart w/RGA)
NEG pump temps c. 230-250 deg C

14.30 ramp

CARME chamber 2.34e-07mbar
Backing 4.1e-07mbar (Edwards vacuum cart w/RGA)
NEG pump temps c. 330-350 deg C

14.45 ramp

CARME chamber 4.02e-07mbar
Backing 4.1e-07mbar (Edwards vacuum cart w/RGA)
NEG pump temps c. 450-455 deg C

15.00 hold

CARME chamber 4.56e-07mbar
Backing 5.7e-07mbar (Edwards vacuum cart w/RGA)
NEG pump temps c. 500-505 deg C
output c. 50V, c. 3A, c. 150W

15.20 hold

CARME chamber 4.40e-07mbar
Backing 5.1e-07mbar (Edwards vacuum cart w/RGA)
NEG pump temps c. 530-540 deg C
output c. 160-170W

15.40 hold

CARME chamber 3.46e-07mbar
Backing 4.3e-07mbar (Edwards vacuum cart w/RGA)
NEG pump temps c. 540-545 deg C
output c. 160-170W

15.50 cycle complete

Ramp 45 mins
Hold inf mins
set output 60W

re-start CARME bakeout
set point +120 deg C

15.55 ramp

CARME chamber 5.15e-08mbar
Backing 1.4e-07mbar (Edwards vacuum cart w/RGA)
NEG pump temps c. 350-360 deg C

16.15 ramp

CARME chamber 4.53e-08mbar
Backing 1.5e-07mbar (Edwards vacuum cart w/RGA)
NEG pump temps c. 260-270 deg C

16.17 CARME chamber temperatures - attachment 20
Attachment 1: 20201022_104309.jpg
20201022_104309.jpg
Attachment 2: 20201022_104331.jpg
20201022_104331.jpg
Attachment 3: 20201022_104339.jpg
20201022_104339.jpg
Attachment 4: 20201022_104345.jpg
20201022_104345.jpg
Attachment 5: 20201022_104354.jpg
20201022_104354.jpg
Attachment 6: 20201022_104354.jpg
20201022_104354.jpg
Attachment 7: 20201022_104412.jpg
20201022_104412.jpg
Attachment 8: 20201022_104415.jpg
20201022_104415.jpg
Attachment 9: 20201022_104419.jpg
20201022_104419.jpg
Attachment 10: 20201022_104427.jpg
20201022_104427.jpg
Attachment 11: 20201022_104431.jpg
20201022_104431.jpg
Attachment 12: 20201022_104434.jpg
20201022_104434.jpg
Attachment 13: 20201022_135913.jpg
20201022_135913.jpg
Attachment 14: 20201022_135921.jpg
20201022_135921.jpg
Attachment 15: 20201022_135926.jpg
20201022_135926.jpg
Attachment 16: 20201022_135930.jpg
20201022_135930.jpg
Attachment 17: 20201022_135935.jpg
20201022_135935.jpg
Attachment 18: 20201022_135942.jpg
20201022_135942.jpg
Attachment 19: 20201022_161737.jpg
20201022_161737.jpg
  31   Wed Oct 28 10:41:57 2020 TDWednesday 28 October
10.32

CARME chamber 5.8e-12mbar (see attachment 1)
Backing 1.6e-08mbar (Edwards vacuum cart w/RGA)

CARME temps - see attachment 2

All SAES D2000-10 & UHV1400 NEG power OFF
All SAES D2000-10 ion pump OFF
Gate valve open

11.01

All SAES D2000-10 ion pump ON

#  V/V       presssure/mbar
1  5012/5019  4-8e-11
2  5012      < 8.9e-12
3  5012      < 8.9e-12
4  5012      < 8.9e-12

11.04

CARME chamber 5.7e-12mbar
Backing 1.7e-08mbar (Edwards vacuum cart w/RGA)

12.12

CARME chamber 5.3e-12mbar
Backing 1.7e-08mbar (Edwards vacuum cart w/RGA)

All SAES D2000-10 & UHV1400 NEG power OFF
Gate valve open
All SAES D2000-10 ion pump ON

#  V/V       presssure/mbar
1  5012      < 8.9e-12
2  5012      < 8.9e-12
3  5012      < 8.9e-12
4  5012      < 8.9e-12

All ion pumps now stabilising wrt V/I/pressure

log (pressure) versus time - see attachment 3

16.00

CARME chamber 4.9e-12mbar - see attachment 4
Backing 1.7e-08mbar (Edwards vacuum cart w/RGA)

All SAES D2000-10 & UHV1400 NEG power OFF
Gate valve open
All SAES D2000-10 ion pump ON - see attachment 5

#  V/V       presssure/mbar
1  5012      < 8.9e-12
2  5012      < 8.9e-12
3  5012      < 8.9e-12
4  5012      < 8.9e-12

All ion pumps now stabilising wrt V/I/pressure

CARME temps - see attachment 6

Observing pressure transients from 5e-12mbar to c. 6-7e-12mbar which recover in c. 5-10 minutes 

21.00 CARME chamber 4.7e-12mbar
Attachment 1: 20201028_103204.jpg
20201028_103204.jpg
Attachment 2: 20201028_103638.jpg
20201028_103638.jpg
Attachment 3: 28102020_pump_down.png
28102020_pump_down.png
Attachment 4: 20201028_161049.jpg
20201028_161049.jpg
Attachment 5: 20201028_155823.jpg
20201028_155823.jpg
Attachment 6: 20201028_155940.jpg
20201028_155940.jpg
  35   Wed Nov 25 10:39:37 2020 TDWednesday 25 November
10.39

CARME XHV chamber pressure 6.0e-12mbar
Backing 2.1e-08mbar (Edwards vacuum cart w/RGA)

CARME temps - heaters OFF - chamber at ambient 
temperature

All SAES D2000-10 & UHV1400 NEG power OFF
All SAES D2000-10 ion pump ON

#  V/V       presssure/mbar
1  5012      < 8.9e-12
2  5012      < 8.9e-12
3  5012      < 8.9e-12
4  5012      < 8.9e-12

Gate valve open

attachment 1 - analog RGA scan (as found this am)

attachment 2 - scan mode 

c. 11.15

AH partially closes gate valve using c. 2 bar air pressure

VCARME XHV chamber pressure increases c. 7e-9mbar immediately

attachment 3 - RGA scan - no obvious change in RGA trends!

attachments 4 & 5 - VAT valve indicators - upper (partially open/closed) and lower (closed)

11.33 CARME XHV chamber pressure 6.6e-9mbar
Backing 2.2e-08mbar (Edwards vacuum cart w/RGA)

All SAES D2000-10 ion pump ON

#  V/V       presssure/mbar
1  5012      < 8.9e-12
2  5012      < 8.9e-12
3  5012      < 8.9e-12
4  5012      < 8.9e-12

All SAES D2000-10 ion pump OFF

11.40 CARME XHV chamber pressure 5.64e-9mbar

11.46 CARME XHV chamber pressure 5.01e-9mbar
No change in RGA trends!

12.01 CARME XHV chamber pressure 3.78e-9mbar
No change in RGA trends!

12.11 CARME XHV chamber pressure 3.10e-9mbar

12.42 CARME XHV chamber pressure 1.81e-9mbar
Backing 2.4e-08mbar (Edwards vacuum cart w/RGA)
No change in RGA trends!

13.20 CARME XHV chamber pressure 1.06e-9mbar
Backing 2.4e-08mbar (Edwards vacuum cart w/RGA)
No change in RGA trends!

13.36 CARME XHV chamber pressure 8.93e-10mbar
Backing 2.4e-08mbar (Edwards vacuum cart w/RGA)
No change in RGA trends!

13.59 CARME XHV chamber pressure 7.07e-10mbar
Backing 2.5e-08mbar (Edwards vacuum cart w/RGA)
No change in RGA trends!

14.00 Leybold turbo OFF - decelerating

14.30 Leybold turbo OFF - decelerating - 466Hz
CARME XHV chamber pressure 5.62e-10mbar
Backing 2.1e-08mbar (Edwards vacuum cart w/RGA)
No change in RGA trends!

14.40 1x SAES D2000-10 ion pump switched on briefly - settles in c. 10s - pressure < 8.9e-
12mbar
All 4x D2000-10 ion pumps OFF

15.01 Leybold turbo OFF - decelerating - 125Hz
CARME XHV chamber pressure 4.78e-10mbar
Backing 1.4e-08mbar (Edwards vacuum cart w/RGA)
No change in RGA trends!

15.10 Abrupt increase in RGA trends - see attachment 6
Leybold turbo OFF - decelerating - 60Hz
CARME XHV chamber pressure 4.53e-10mbar
Backing 2.6e-08mbar (Edwards vacuum cart w/RGA)

15.19 4x SAES D2000-10 ion pumps ON
RGA record 04.24.00 

15.24 see attachment 7 - RGA transient recovering - turbo stopped?

15.10 Leybold turbo OFF - stopped - 0Hz
CARME XHV chamber pressure 4.40e-10mbar
Backing 1.1e-08mbar (Edwards vacuum cart w/RGA)

All SAES D2000-10 ion pump ON

#  V/V       presssure/mbar
1  5012      < 8.9e-12
2  5012      < 8.9e-12
3  5012      < 8.9e-12
4  5012      < 8.9e-12

16.10 VAT gate valve partially closed
Leybold turbo OFF - stopped - 0Hz
CARME XHV chamber pressure 3.88e-10mbar
Backing 9.8e-09mbar (Edwards vacuum cart w/RGA)
RGA traces recovered to pre-transient levels and stable

All SAES D2000-10 ion pump ON

#  V/V       presssure/mbar
1  5012      < 8.9e-12
2  5012      < 8.9e-12
3  5012      < 8.9e-12
4  5012      < 8.9e-12
Attachment 1: 20201125_104631.jpg
20201125_104631.jpg
Attachment 2: 20201125_110500.jpg
20201125_110500.jpg
Attachment 3: 20201125_111937.jpg
20201125_111937.jpg
Attachment 4: 20201125_111954.jpg
20201125_111954.jpg
Attachment 5: 20201125_112003.jpg
20201125_112003.jpg
Attachment 6: 20201125_151232.jpg
20201125_151232.jpg
Attachment 7: 20201125_152354.jpg
20201125_152354.jpg
  36   Fri Dec 4 16:49:36 2020 TDFriday 4 December
Attachment 1: 20201204_161412.jpg
20201204_161412.jpg
Attachment 2: 20201204_161400.jpg
20201204_161400.jpg
Attachment 3: 20201204_161354.jpg
20201204_161354.jpg
Attachment 4: 20201204_161348.jpg
20201204_161348.jpg
Attachment 5: 20201204_161340.jpg
20201204_161340.jpg
Attachment 6: 20201204_161313.jpg
20201204_161313.jpg
Attachment 7: 20201204_161259.jpg
20201204_161259.jpg
  56   Fri Sep 3 14:14:40 2021 TDLeybold IE514 manual & calibration data
Attachment 1: 20210903_141201.jpg
20210903_141201.jpg
Attachment 2: Ionivac_Sensors_IE414_IE514.pdf
Ionivac_Sensors_IE414_IE514.pdf Ionivac_Sensors_IE414_IE514.pdf Ionivac_Sensors_IE414_IE514.pdf Ionivac_Sensors_IE414_IE514.pdf Ionivac_Sensors_IE414_IE514.pdf Ionivac_Sensors_IE414_IE514.pdf Ionivac_Sensors_IE414_IE514.pdf Ionivac_Sensors_IE414_IE514.pdf
  119   Wed Oct 13 11:59:23 2021 TD[How to] Open COF600 copper wire seals
Use the M10 jacking points provided top/bottom and 
left/right on the upstream and downstream sides of the 
flanges - for example see attachments 1 & 2
Attachment 1: 20211013_103806.jpg
20211013_103806.jpg
Attachment 2: 20211013_103800.jpg
20211013_103800.jpg
  121   Wed Oct 13 15:16:12 2021 TDOrientation of 2x 78 way D connector feedthroughs
Looking downstream

Attachment 1 top right pair
           2 bottom right pair
           3 bottom left pair
           4 top left pair

PB "The long sides of the connectors on the 2 lowest flanges should be next to each other
and the short side of the connectors should be towards the motors."

The orientations of the other flanges do not matter.

'Long' cables to L-R connectors, 'short' cables to U-D connectors.
Attachment 1: 20211013_152518.jpg
20211013_152518.jpg
Attachment 2: 20211013_152529.jpg
20211013_152529.jpg
Attachment 3: 20211013_152549.jpg
20211013_152549.jpg
Attachment 4: 20211013_152606.jpg
20211013_152606.jpg
  129   Fri Oct 22 13:11:26 2021 TDMSL type TTT14 assembly drawings & pin assignments
Attachment 1: C-3434.pdf
C-3434.pdf C-3434.pdf C-3434.pdf C-3434.pdf
Attachment 2: C-3517.pdf
C-3517.pdf C-3517.pdf C-3517.pdf C-3517.pdf C-3517.pdf
  130   Fri Oct 22 13:22:48 2021 TDCARME FEE64 adaptor PCB
Attachment 1: 3D.pdf
3D.pdf
Attachment 2: Bottom_Ground_Pad.pdf
Bottom_Ground_Pad.pdf
Attachment 3: Flex_Layer_1.pdf
Flex_Layer_1.pdf
Attachment 4: Flex_Layer_2.pdf
Flex_Layer_2.pdf
Attachment 5: Flex_Layer_3.pdf
Flex_Layer_3.pdf
Attachment 6: Flex_Layer_4_(1).pdf
Flex_Layer_4_(1).pdf
Attachment 7: PCB_Bottom.pdf
PCB_Bottom.pdf
Attachment 8: PCB_Top.pdf
PCB_Top.pdf
Attachment 9: Silkscreen_Top.pdf
Silkscreen_Top.pdf
Attachment 10: Top_Ground_Pad.pdf
Top_Ground_Pad.pdf
  332   Mon Feb 28 14:38:15 2022 TDNewMerger statistics
Screenshots of all NewMerger statistics
Attachment 1: Screenshot_from_2022-02-28_15-38-04.png
Screenshot_from_2022-02-28_15-38-04.png
Attachment 2: Screenshot_from_2022-02-28_15-37-57.png
Screenshot_from_2022-02-28_15-37-57.png
Attachment 3: Screenshot_from_2022-02-28_15-37-52.png
Screenshot_from_2022-02-28_15-37-52.png
Attachment 4: Screenshot_from_2022-02-28_15-37-44.png
Screenshot_from_2022-02-28_15-37-44.png
Attachment 5: Screenshot_from_2022-02-28_15-37-32.png
Screenshot_from_2022-02-28_15-37-32.png
Attachment 6: Screenshot_from_2022-02-28_15-37-24.png
Screenshot_from_2022-02-28_15-37-24.png
Attachment 7: Screenshot_from_2022-02-28_15-37-10.png
Screenshot_from_2022-02-28_15-37-10.png
Attachment 8: Screenshot_from_2022-02-28_15-37-03.png
Screenshot_from_2022-02-28_15-37-03.png
Attachment 9: Screenshot_from_2022-02-28_15-36-55.png
Screenshot_from_2022-02-28_15-36-55.png
Attachment 10: Screenshot_from_2022-02-28_15-36-48.png
Screenshot_from_2022-02-28_15-36-48.png
Attachment 11: Screenshot_from_2022-02-28_15-36-39.png
Screenshot_from_2022-02-28_15-36-39.png
Attachment 12: Screenshot_from_2022-02-28_15-36-31.png
Screenshot_from_2022-02-28_15-36-31.png
Attachment 13: Screenshot_from_2022-02-28_15-36-23.png
Screenshot_from_2022-02-28_15-36-23.png
Attachment 14: Screenshot_from_2022-02-28_15-36-16.png
Screenshot_from_2022-02-28_15-36-16.png
Attachment 15: Screenshot_from_2022-02-28_15-36-07.png
Screenshot_from_2022-02-28_15-36-07.png
Attachment 16: Screenshot_from_2022-02-28_15-35-59.png
Screenshot_from_2022-02-28_15-35-59.png
Attachment 17: Screenshot_from_2022-02-28_15-35-51.png
Screenshot_from_2022-02-28_15-35-51.png
Attachment 18: Screenshot_from_2022-02-28_15-35-42.png
Screenshot_from_2022-02-28_15-35-42.png
Attachment 19: Screenshot_from_2022-02-28_15-35-36.png
Screenshot_from_2022-02-28_15-35-36.png
Attachment 20: Screenshot_from_2022-02-28_15-35-26.png
Screenshot_from_2022-02-28_15-35-26.png
Attachment 21: Screenshot_from_2022-02-28_15-35-14.png
Screenshot_from_2022-02-28_15-35-14.png
Attachment 22: Screenshot_from_2022-02-28_15-35-09.png
Screenshot_from_2022-02-28_15-35-09.png
Attachment 23: Screenshot_from_2022-02-28_15-34-52.png
Screenshot_from_2022-02-28_15-34-52.png
Attachment 24: Screenshot_from_2022-02-28_15-34-47.png
Screenshot_from_2022-02-28_15-34-47.png
Attachment 25: Screenshot_from_2022-02-28_15-34-42.png
Screenshot_from_2022-02-28_15-34-42.png
Attachment 26: Screenshot_from_2022-02-28_15-34-35.png
Screenshot_from_2022-02-28_15-34-35.png
Attachment 27: Screenshot_from_2022-02-28_15-34-28.png
Screenshot_from_2022-02-28_15-34-28.png
Attachment 28: Screenshot_from_2022-02-28_15-34-20.png
Screenshot_from_2022-02-28_15-34-20.png
Attachment 29: Screenshot_from_2022-02-28_15-34-12.png
Screenshot_from_2022-02-28_15-34-12.png
Attachment 30: Screenshot_from_2022-02-28_15-34-03.png
Screenshot_from_2022-02-28_15-34-03.png
Attachment 31: Screenshot_from_2022-02-28_15-33-50.png
Screenshot_from_2022-02-28_15-33-50.png
Attachment 32: Screenshot_from_2022-02-28_15-33-45.png
Screenshot_from_2022-02-28_15-33-45.png
Attachment 33: Screenshot_from_2022-02-28_15-33-39.png
Screenshot_from_2022-02-28_15-33-39.png
Attachment 34: Screenshot_from_2022-02-28_15-33-31.png
Screenshot_from_2022-02-28_15-33-31.png
Attachment 35: Screenshot_from_2022-02-28_15-33-24.png
Screenshot_from_2022-02-28_15-33-24.png
Attachment 36: Screenshot_from_2022-02-28_15-33-15.png
Screenshot_from_2022-02-28_15-33-15.png
Attachment 37: Screenshot_from_2022-02-28_15-33-07.png
Screenshot_from_2022-02-28_15-33-07.png
  386   Wed Mar 22 16:33:32 2023 TDNIM WR source
Test of NIM WR source at Edinburgh

Attachment 1 - NIM WR source

NIM module upper SMA - DSO ch 1
NIM module lower SMA - DSO ch 2

Attachment 2

NO SYNC or CLK signals observed.

Noise observed with NIM bin power ON *and* OFF

Attachment 3

NIM WR source in EG&G Ortec NIM bin



... and with the Digilent Zybo board switched ON!


Attacments 4-7
Trigger ch 2
4, 40, 400 & 4000ns/div

Attachment 8
Trigger ch 1
4ns/div
Attachment 1: 20230322_155735.jpg
20230322_155735.jpg
Attachment 2: 20230322_160448.jpg
20230322_160448.jpg
Attachment 3: 20230322_160453.jpg
20230322_160453.jpg
Attachment 4: 20230322_181015.jpg
20230322_181015.jpg
Attachment 5: 20230322_181027.jpg
20230322_181027.jpg
Attachment 6: 20230322_181045.jpg
20230322_181045.jpg
Attachment 7: 20230322_181054.jpg
20230322_181054.jpg
Attachment 8: 20230322_180945.jpg
20230322_180945.jpg
  400   Sun May 14 11:55:12 2023 TDSunday 14 May
12.44 DSSSD#3 bias -149.95V leakage current -6.448uA temperature +19.7 deg C ( https://web-docs.gsi.de/~lestinsk/tempplot.php )

CRYRING cave lights ON - leakage current measurements @ 60s intervals

6.448
6.449
6.448
6.448
6.449
6.448
6.448
6.448
6.449
6.448

18.24 DSSSD#3 bias -149.95V leakage current -6.442uA temperature + 21.0 deg C ( https://web-docs.gsi.de/~lestinsk/tempplot.php )

CRYRING cave lights ON - leakage current measurements @ 60s intervals

6.441
6.441
6.441
6.441
6.441
6.442
6.442
6.442
6.440
6.441
  401   Mon May 15 07:34:22 2023 TDMonday 15 May
08.35 DSSSD#3 bias -149.95V leakage current -6.418uA temperature +19.6 deg C ( https://web-docs.gsi.de/~lestinsk/tempplot.php )

DSSSD#3 bias OFF
  418   Thu Jul 13 08:46:44 2023 TDReplacing wire seal
09.30 CARME chamber status

      Edwards scroll pump ON
      Edwards Speedivac valves #1 & #2 OPEN
      VAT gate valves OPEN

      Re-connect Leybold Pirani gauge to local display/control
      CARME chamber pressure 2.4mbar

      Scroll pump should be able to achieve < 0.1mbar - indicates significant leak

      Davide will first check bolt torques for all flanges opened during most recent vacuum cycle

12.05 Additional torque did not resolve problems
      ML test COF600 seal with isopropanol and observed increased chamber pressure

      Will open COF600 seal after lunch

13.55 COF600 seal removed - one section marked by Kapton tape shows some distortion and a burr on the inner diameter - see attachments 1 & 2. 


      ML speculated that perhaps the seal was lightly too long and a section of circumference was forced outwards?
      Vacuum surfaces cleaned with isopropanol and tissues - red/brown discoloration probably indicating copper observed

14.30 New COF600 seal installed, flanges closed, bolts finger tight, bolts then systematically torqued in small increments 

      COF600 torques finger tight, 10, 20, 30, 40, 60, 80, 100, 120, 140, 160Nm x2
      DN100 flanges doenstream finger tight, 8, 16, 24Nm

16.40 Start scroll pump and slowly rough chamber

18.00 Roughing CARME chamber pressure flatlines c. 30mbar indicating a large leak.
      ML ran some isopropanol around COF600 flange and observed response in roughing pressure of c. 0.2-0.3mbar at c. 30mbar which appears to confirm COF600 is leaking.


      
Attachment 1: 20230713_135351.jpg
20230713_135351.jpg
Attachment 2: 20230713_135416.jpg
20230713_135416.jpg
  419   Fri Jul 14 08:27:17 2023 TDCARME open - inspecting seal
09.20 CARME chamber at atmospheric pressure as expected.

      Will open CARME chamber and inspect COF600 wire seal for similar (or other) issues to the seal removed yesterday. One possibility is that the COF600 flange 
surfaces/structures are misaligned and part of seal is 'escaping' the seal zone. Given the flanges close easily the misalignment would have to be small.

13.30 Observations

      The bolts on the upstream feet of the far detector chamber are all loose and have probably been so for some time

      Based on measurements with calipers and the insertion of shims into the *radial* gap between COF600 flange surfaces the COF600 flanges may be misaligned and rotated 
transversely by a fraction of a millimeter. The challenge is that the chamber is not designed for fine transverse adjustments and it is not easy to measure the changes.

      The Pfeiffer recommended procedure for closing COF seals is to start tightening bolts *diametrically* and then to tighten sequentially

https://www.pfeiffer-vacuum.com/en/know-how/mechanical-components-in-vacuum/connections/detachable-flange-connections/cof-flanges/

     The plan

     Adjust position of far detector chamber and secure upstream feet bolts

     Close COF600 flange using Pfeiffer recommended procedure

     Today is Friday so it will probably be Monday before we can pump the CARME chamber

13.50 Another view

     Grosmontage also inspected the COF600 seal this afternoon. They said that it was important that the seal should be installed under tension to ensure that it remained 
in position as the flanges were closed and the bolts begin to be tightened. They think the seals are a little too large in circumference but that they can shorten one on 
Monday morning. 
  420   Mon Jul 17 08:45:11 2023 TDClosing CARME again
Grosmantage are scheduled to arrive 10.00 to inspect COF600 seals and their fit to the COF600 flange. They may decide to adjust the seals so that they fit the flange 
under 
tension.

Once Grosmontage are satisfied with the seal and its fit we can close the CARME chamber and start pumping down. 

Attachment 1 - photo of bakeout tent parts including those adapted/modified by Davide.


18.40 Grosmontage were re-tasked this morning.

      Davide, Omer, Cosmas checked alignment of COF600 male and female flanges.

      4x COF600 seals were checked - for some seals we observed wave over a ~ 10cm section of the circumference and/or surface scratches/roughness.
      Also observed that COF600 seals appeared to be too large - consequently the wire seal would be seated well ( i.e. in contact with the flange surface )
      for the majority of the circumference but would lift from flange surface for part(s) of the circumference.
      The fourth COF600 seal seated well over all of the circumference and we decided to proceed with closing the chamber.

      COF600 flange bolts tightened sequentially 5, 10, 20, 30, 40, 60, 80, 100, 120, 140, 160Nm.

      ML roughed CARME chamber slowly ( < 1mbar/s ) to protect Be window. Turbo started at 1.3mbar. Pirani gauge indicated e-3 mbar range when turbo at speed.


18.53 IE514 gauge ON pressure 4.05e-5mbar.

19.10 Pirani 1.42e-3 mbar IE514 3.02e-5 mbar
Attachment 1: 20230717_093106.jpg
20230717_093106.jpg
  421   Tue Jul 18 08:16:28 2023 TDPumping down. Issues found with one detector.
09.15 Following overnight pumping of CARME chamber by Leybold turbo
      Pirani 1.00e-3 mbar IE514 2.83e-7 mbar

     The Leybold IE514 gauge currently in use is the CARME unit ( serial # 1054 ). The calibration data can be found at https://elog.ph.ed.ac.uk/CARME/56


09.44 Pirani 1.00e-3 mbar IE514 2.71e-7 mbar

10.10 Leak tester attached to backing line

      Valves to leak tester and turbo (connection to Edwards scroll pump in between) closed.

      Stop Edwards scroll pump with magnetic valve 'red' button - magnetic valves closes and Edwards scroll pump is switched off.

      Open valves to leak tester and then (slowly) turbo.

      Wait for leak tester to settle in e-12 mbar.l/s range. Leak tester pressure 3.6e-3 mbar. IE514 2.69e-7 mbar.

11.00 Pirani 1.00e-3 mbar IE514 2.42e-7 mbar
      Leak tester 1.8e-10 mbar.l/s

13.04 Pirani 1.00e-3 mbar IE514 2.06e-7 mbar

      Leak testing.
      Downstream DN100 flanges from CARME to dipole OK
      Lower NEG power connector feedhtrough (downstream chamber) OK
      Left hand side (looking downstream) bellows OK

      c. few e-9 mbar.l/s leak bottom left (lookimg downstream) of COF600 wire seal

      Additional torque to M16 bolts bottom left - c. 10 bolts -> 220Nm+

      c. 0.1-0.3e-11 mbar.l/s

      Further checks around circumference of COF600 seal reveal some small leaks c. e-11-12 mbar.l/s.? However background rate
      in leak tester too high for sensitive test - will await recovery to resume checking.

14.00 Pirani 9.8e-4 mbar IE514 1.96e-7 mbar
      Leak tester 4.9e-10 mbar.l/s


14.35 DSSSD test
      IE514 OFF

Ambient temperature 21.5 deg C

Top right
-10V -4uA
-20V 10uA
c. -30V > -20uA trip

Top left
-150V -5.15uA

Bottom left
-150V -4.97uA

Bottom right
-150V -6.33uA

Top right (repeat)
-20V -10uA
-25V -14uA

15.28 IE514 ON
      Pirani 9.8e-4 mbar IE514 1.87e-7 mbar

15.40 c. few e-9 mbar.l/s leak around magnetic valve - probably not an issue in terms of backing performance but may interfere with/confuse leak testing

16.05 Pirani 9.8e-4 mbar IE514 1.74e-7 mbar
      Leak tester 1.2e-9 mbar.l/s

Will leave CARME pumping with leak tester on roughing line and see whether leak rate recovers. If so, will continue leak tests tomorrow. 

18.50 Pirani 1.00e-3 mbar IE514 1.48e-7 mbar
      Leak tester < 1e-12 mbar.l/s (leak tester valved off)
  422   Wed Jul 19 08:17:26 2023 TDLeak testing
09.16 Pirani 1.00e-3 mbar IE514 8.77e-8 mbar
      Leak tester c. 5e-12 mbar.l/s (leak tester valved off)

09.48 Pirani 1.00e-3 mbar IE514 8.67e-8 mbar
      Leak tester c. 3.5e-12 mbar.l/s (leak tester valved off)

10.33 Pirani 1.00e-3 mbar IE514 8.55e-8 mbar
      Leak tester c. 4e-10 mbar.l/s (leak tester connected to CARME roughing line)

10.55 Leak tester remains at few e-10 mbar.l/s - we do not understand why
      With leak tester in differential mode the highest reading around the COF600 seal is c. 3.5e-12 mbar.l/s
      Following checks elsewhere on the chamber we observe c. 6e-12 mbar.l/s which presumably reflects accumulation of He around the chamber 

      Dispersing He with compressed air reduces diff mode reading to c. 2e-12 mbar.l/s

11.00 Pirani 9.80e-4 mbar IE514 8.47e-8 mbar

14.49 Pirani 1.00e-3 mbar IE514 7.71e-8 mbar
      Leak tester isolated from CARME backing line - CARME Edwards scroll pump now backing turbo.
  423   Thu Jul 20 08:29:26 2023 TDInstalling tent. Two NEG power cable broken.
09.28 Pirani 1.00e-3 mbar IE514 5.45e-8 mbar

12.10 Bakeout tent frame installed
      SAES UHV1400 NEG pump power cables #1-6 installed
      See attachments 1 & 2

16.35 Attachments 3-6
      upstream baseplate
      3x sets of heaters beneath CARME chamber connected to CRYRING heater/TC manifold - attachments 7-8

      
16.45 Pirani 1.00e-3 mbar IE514 4.80e-8 mbar


17.10 SAES D-2000 #1 downstream, outside   NEG power + HV ( attachment 9 - OK cable connector )
      SAES D-2000 #3 downstream, inside   NEG power + HV
      SAES D-2000 #4 upstream, inside   HV
      SAES D-2000 #2 upstream, outside   HV

2x ( of 4x ) SAES D-2000 neg power cables were broken - forward-shell detached (unscrewed ) from back-shell remaining attached to D-2000 neg power connector. 
Re-assembly is straightforward but it is unclear how the 6x female sockets are aligned with the connector keys of the forward-shell (attachments 10-11 cf. attachment 9).
Until this is understood these 2x SAES D-2000 neg power cables should not be used.
Attachment 1: 20230720_120957.jpg
20230720_120957.jpg
Attachment 2: 20230720_121016.jpg
20230720_121016.jpg
Attachment 3: 20230720_162938.jpg
20230720_162938.jpg
Attachment 4: 20230720_163700.jpg
20230720_163700.jpg
Attachment 5: 20230720_163651.jpg
20230720_163651.jpg
Attachment 6: 20230720_163655.jpg
20230720_163655.jpg
Attachment 7: 20230721_093447.jpg
20230721_093447.jpg
Attachment 8: 20230721_093452.jpg
20230721_093452.jpg
Attachment 9: 20230721_092923.jpg
20230721_092923.jpg
Attachment 10: 20230721_094608.jpg
20230721_094608.jpg
Attachment 11: 20230721_094642.jpg
20230721_094642.jpg
ELOG V3.1.4-unknown