ID |
Date |
Author |
Subject |
566
|
Fri May 31 19:12:01 2024 |
CB, EM | Run 13 - test with beam | 20:00
The beam is set at the correct energy, operators cross-checked it again. What we see at 750 is due to the molecular beam. The operotors are trying to optimize and get rid of this in the next 30min.
Temps and system checks OK
Leakage current OK
Merger and tape server OK
Potentiometer at 28.06 mm and 29.23 mm
20:30
Keep going with the beam tests. A new peak appears around 950 keV( See attached). Still try to understand what it is. The operators keep going |
565
|
Fri May 31 06:01:55 2024 |
JM, TY, PW, EM, CB | Run 12 - beam on target | 07:00
Run 12 started. D+ beam is incident on the target at 1.5 MeV
Beam intensity in the ring is ~4e7 particles
Target density shows some fluctuations but is ~1e11 atoms/cm2. Target temp 35K
Detectors are positioned fully out (Left arm 18.86mm and right arm 19.8 mm ) and are not moving
Ring pressure looks OK, YR09 E target sensor seems unaffected by the target currently reads ~5e-11 mbar.
Beam is in the ring for ~15s.
Temps and system checks OK
Leakage current OK
Merger and tape server OK
Horizontal beam position 8 mm and vertical beam position 0mm for overlap with target.
Statistics - attachment 1
Energy histogram - attachment 2
XY plot - attachment 3
We see high rate at 1.5 MeV in left dssds but very little in right dssds. XY plots also show counts are concerntrated in a very circular distribution.
07:15
Gleb has just called and requires access to the cave to check on a turbo pump in the source.
Ring vacuum looks good
Beam will be down for 10-15 minutes only hopefully.
07:45
Beam is back in the ring but injection requires optimisation.
09:00
There are some issues with the source that require a few hours to resolve. Potentially until 7 or 8 pm tonight. We have about an hour before work starts.
We have done a quick test of the motors and moved the left and right arms in using the pnuematic only.
New position left arm = 62.71 mm , right arm = 64.6 mm.
We observed the rates in left detectors went up significantly. In the right detectors we observed little increase.
See attached xy plot - attachment 4
See attached energy histogram - attachment 5
Beam intensity has dropped significantly - below 1e6 particles so even at in positons we see few counts at the moment.
09:25
Source has degraded pretty rapidly so beam will be stopped for now.
Detectors moved back out.
Target nozzle moved from X= -13000, Y=2500 to X= -11000, Y=2500. S1 has dropped to 5e-10 mbar.
Note Gleb mentioned that last night it was likely a large proportion of the ions stored were molecular hydrogen not deuterium.
16:18
Temps and system checks OK
Leakage current OK
Merger and tape server OK
18:10
Temps and system checks OK
Leakage current OK
Merger and tape server OK
19:38
Operators are trying to optimize some beam. For now the beam is lower than it should be probably because is easy to work with the source like that.
Temps and system checks OK
Leakage current OK
Merger and tape server OK
|
564
|
Thu May 30 13:31:01 2024 |
JM, CB, PW, YL | Run 11 - beam on target overlap | 14:30
Run 11 started. D+ beam in the ring at 1.5 MeV.
No target at the moment. Valves to the interaction chamber will soon be opened.
Stats and histograms zero'd, monitoring code reset.
All checks and temps OK
Leakage currents OK
ADC data items statistics - attachment 1
Beam in ring ~30s and manipulation ~2s
Beam intensity ~ 5.7E7
16:40
System check OK
Temperature OK
Statistics same as before
Merger and server OK
Leakage currents OK
Beam in the ring
Waiting for target , Hydrogen green
18:50
System OK
Temperature OK
Statistics same as before
Merger and server OK
Leakage currents OK
Beam ~4x10^7
Target tuning ongoing
22:05
System OK
Temperature OK
Statistics same as before
Merger and server OK
Leakage currents OK
Currently no beam -> asked operator to check source
Target tuning ongoing
23:22
System OK
Temperature OK
Statistics same as before
Merger and server OK
Leakage currents OK
Currently no beam -> operators are optimizing the intensity of the beam
Optimizing target density as well
00:55
The overlaping test started by moving the beam only in the y axis.
02:00
Overlap test is over and was found that the optimal position for the horizontal axis is 8mm. Beam on target.
Observation of an increase the 1.5 MeV peak in the CARME monitoring code when overlap with the target is found. Attachment 4.
Drop in the beam lifetime is also observed when overlapped with the target.
System OK
Temperature OK
Statistics same as before
Merger and server OK
Leakage currents OK
02:48
CRYRING measurement cycle has been made shorter (from 5 to 3 repetitions) to match it with the decreased beam life time due to optimed overlap with target.
04:37
System OK
Temperature OK
Statistics same as before
Merger and server OK
Leakage currents OK
|
563
|
Thu May 30 09:30:33 2024 |
CB, PW, YL, TD | Run 10 | 10:30
Merger OK, Tape server OK
ADC data item statistics looks as before. OK
FEE temperatures look OK
System checks OK
Leakage current stable
10.48 FEE64 temperatures OK - attachment 1
WR timestamps OK - attachment 2
ADC data item stats - attachment 3
per FEE64 Rate spectra - attachment 4
why do we observe HEC data in aida15 asic #1?
per FEE64 1.8.L spectra - attachments 5-6
ADC to 20MeV FSR - not clear when these spwectra were last zero;d
currently 750keV/u D + no target ?
10.53 All histograms & stats zero'd
Merger, Taper Server etc - attachments 7-8
bind error 98 for NewMerger server - not clear when these messahes were generated - added some returns to monitor whether these, or other, messages are repeated
DSSSD bias & leakage current OK - attachment 9
11:30
We noticed some odd peak structure in the rate energy histograms for the right hand side detectors. We took away the beam but this structure persisted.
This was not observed in the total energy histograms, the reason for this is the applied multiplicity cut to the total histograms. Removing this cut the peaks are clearly visible (attachment 10). Putting the cut back in we see the peaks removed (attachment 11). These events correspond to some noisy strips on the detectors on the right hand side (see attachment 12). Notice the much larger rate on the RHS. Current ADC data items statistics show FEE modules for the RHS also much larger (attachment 13). We did not observe this with no beam (https://elog.ph.ed.ac.uk/CARME/554) but did with beam last night (https://elog.ph.ed.ac.uk/CARME/558) so there nust be some effect of having beam in the ring increasing the number of events on the RHS. Note the detectors are fully out and the events are localised in these strips.
Note we have moved the detectorsand removed beam from the ring in this time period to investigate these peaks.
12:50
Run 10 continues. Temps OK. System checks OK. Merger OK, Tape server OK.
Leakage current OK.
Notice the 'beam peak' at 1.5 MeV is larger in the left hand side (attachment 14)
14:26
We have started the new_optimeren.py on pi@gas-stepper to try and align the gas target. Valves to the interaction chamber are closed.
Setting the nozzle X=-13000, Y=1000 we observe an increase in E4 from 4E-10 mbar to 2E-9 mbar. Moving either side we observe a drop in E4. We take this as the gas target being aligned.
Anton will now open the valves to the gas target.
Run 10 stopped. |
562
|
Thu May 30 08:33:21 2024 |
CB, PW, YL | Run 8 & 9- detector motion tests | 09:34 - Moved to Run 9 in preparation of moving detectors. No target yet. Beam in the ring at 750 keV/A.
Temperatures OK (attach)
System wide checks OK except 16 fails clock and ADC calib
Rates OK (attach)
Writing to disk OK (attach)
Resetting the sorting script. Moving detectors.
Moved detectors in. See attached. Stripe / shadow quite clear. Some oddities on the top-right DSSD. May be due to ExEy cuts and multiplicity cuts.
Moved on tun run 9 to acquire some stats without motion.
10:13 Temperatures still OK. Rates OK. Leakage currents stable.
We were cutting the beam.
Increased repetition to x5.
Motors fully out - run 10 started. |
561
|
Thu May 30 07:25:53 2024 |
Yuri, Phil, Nikos | Gas target | The cave is closed and beam is back
The d intensity is about half of the intensity before the break
The gas target is prepared but the valvas cannot be opened. Anton is coming in at around 1 PM to open the gate valves. |
560
|
Thu May 30 06:00:51 2024 |
Yuri Nikos ... | Open the cave | Nikos needs to enter the cave to work on the target cooling.
|
559
|
Wed May 29 17:42:06 2024 |
TD | Offline analysis APR24/R2 (pulser walkthrough) | ADC offsets using pulser walkthrough data from data file APR24/R2
ch = channel + ( module * 64 ) + ( range * 2048 )
adc_data( ch ) = INT( RSHIFT( ABS( adc_data( ch ) - 32768 ), 3 ) - offset( ch ) + 0.5 )
per FEE64 ADC spectra - attachments 1-16
Note common x & y-scales - peak height proxy for peak width
aida01 1.8.L (s7) pulser peak width 9 ch FWHM (~50keV FWHM)
ADC offset analysis
/home/td/Calibration/offsets /home/td/CARME/R2 50 2048 20 5
First pass sort variables NAMELIST I/O format ( ADC offsets, FEE64 configuration, LEC & HEC equal energy cuts ) - attachment 17 |
558
|
Wed May 29 16:46:21 2024 |
NP, AB, PM | Run7 - Measurements only with ion beam. | 18:19 Start or run 7: In beam has been optimzed up to now by Zoran and Claude. ~7E7 particles at injection. From now on, only the injection beamline is optimized by Operators.
Detectors IN (left arm pot =18.86 mm, right arm pot = 19.80 mm)
No Target
Beam is in the ring for ~6 seconds and total cycle time between injections is ~8 seconds
Injection beamline is still in process of optimization by operators
21:30
Merger OK, Tape server OK
ADC data item statistics looks as before. OK
FEE temperatures look OK
System checks OK
Leakage current stable
23:30
Merger OK, Tape server OK
ADC data item statistics looks as before. OK
FEE temperatures look OK
System checks OK
Leakage current stable
01:30
Merger OK, Tape server OK
ADC data item statistics looks as before. OK
FEE temperatures look OK
System checks OK
Leakage current stable
Beam and Electron Coller failure (~00:35); Beam back (~01:08); Cooler back (~01:20)
03:00
Merger OK, Tape server OK
ADC data item statistics looks as before. OK
FEE temperatures look OK
System checks OK
Leakage current stable
Beam and Electron Coller failure (~01:35); Beam back (~01:55); Cooler back (~01:55)
04:40
Merger OK, Tape server OK
ADC data item statistics looks as before. OK
FEE temperatures look OK
System checks OK
Leakage current stable
06:00
Merger OK, Tape server OK
ADC data item statistics looks as before. OK
FEE temperatures look OK
System checks OK
Leakage current stable
07:00
Merger OK, Tape server OK
ADC data item statistics looks as before. OK
FEE temperatures look OK
System checks OK
Leakage current stable
|
557
|
Wed May 29 09:49:35 2024 |
JM, CB | Threshold changes / D+ beam | 09:00
R4 alpha background continues, currently R4_12
Temps OK, system checks unchanged from previous status (OK, aida16 clock and ADC issue)
10:30
R4 stopped and moved to the next run R5.
Lithium 3+ beam is not feasible at sufficient densities so we are switching to D+ at a beam energy of 0.75 MeV/u. A measurement of d+p at this energy would produce 3He at energies of ~900 keV.
The current threshold (slow comparator) has been 1 MeV (0x64). We lowered the thresholds in all FEE modules to 200 keV (0x14). ADC rates look fine in all FEEs (~tens of Hz) except in aida 15 and aida 16 which was ~several hundred kHz. Data rate to disk was 1.2 Mb/s
We increased the threshold in aida 15 and 16 only to 500 keV (0x32) and rates in aida 15 and 16 have dropped to <20 kHz. Data rate to disk now 220 kB/s.
11:00
R5 stopped. R6 started - background with reduced thresholds.
Attachment 1 - ADC data items statistics
Attachment 2 - Histogram browser statistics
Attachment 3 - Tape server
Attachment 4 - New Merger
13:12
R6 continues R6_9
Edits to the CARME sort code have been made. EyEx energy cut for online monitoring reduced to 100 keV. Multiplicity cut applies to lowEnergyEy, lowEnergyEx and lowEnergyXY histograms. Multiplicity cut considers only single strip events.
15:00
D+ beam is now in the ring and is being optimised by the beam operators. The CARME detectors are currently fullt out, but we can see some effects of the beam on the online monitoring code. |
556
|
Wed May 29 08:10:32 2024 |
JM | Run4 - alpha background | 09:00
R4 alpha background continues, currently R4_12
Temps OK, system checks unchanged from previous status (OK, aida16 clock and ADC issue) |
555
|
Tue May 28 15:25:21 2024 |
TD, JM, CB | Pulser tests | R3 started
Pulser ON. Approx 2 kHZ.
1.8*w waveforms attachments 1+2
ADC data items statistics - attchment 3
1.8*L spectra - attachments 4+5
Pulser widths are larger than during testing prior to the Feb beamtime. Widths in Channels;
aida01 = 76
aida02 = 82
aida03 = will upate all later tonight..
R3 ended. Pulser OFF
17:15
R4 Started. Alpha background run.
|
554
|
Tue May 28 12:38:31 2024 |
TD, JM, CB | Run 2 - Alpha background run |
13.35 FEE64 temperatures OK - attachment 1
ADC data item rates OK - attachment 2
overall rate dominated by 2x hot channels aida15
per FEE64 Stat spectra - attachment 3
spectra consistent with April alpha background test
note high HEC data stats for aida12 asic#2 - can probably be fixed by ASIC control check
per 1.8.W spectra - 20us FSR - attachments 4-5
note 100kHz ripple observed for some FEE64s cf. https://elog.ph.ed.ac.uk/CARME/544
Run stopped 15:15 |
553
|
Mon May 27 15:25:08 2024 |
JM | Startup | 27/05/24
The carme-gsi computer has been moved from the server room into the shifter control room.
Startup of the DAQ looks OK. Settings loaded 2024Apr24
System wide checks OK. Aida16 clock status fails. Aida16 ADC calibration fails. Rest OK.
All FEEs look OK, we again see high rates in aida15 ~ 12k data items/sec, rate in other FEEs is 0.
Testing of the pulser widths has been done. Pulser widths will be uploaded soon.
Background run started. No beam, no target. File G22-201 and R2. Data being written is ~128 kb/s. Run will be left overnight, no night shift.
28/05/24
DAQ continues with alpha background run.
System wide checks OK. Aida16 clock status fails. Aida16 ADC calibration fails. Rest OK. Temps OK
Data can be seen in the spectrum browser on MIDAS. CARME monitoring code was started incorrectly yesterday. It has now be restarted and a small number of events are seen |
552
|
Fri May 10 21:23:35 2024 |
TD, CB, JM | 20Ne7+ test beam | 22.00
Carsten Brandau stopping e-target experiment Unattended beam overnight. No operators watching.
10^5 (nominal) 20Ne7+ at 380keV/u beam available
Carsten reports beam is unstable, often disappearing, and in bunched mode.
4x MSL type TTT14 DSSSDs not moving, locked in out position
Starting CARME MIDAS DAQ ASIC settings 2024Apr24-14.14.03
slow comparator 0x64 E
G&G Ortec 448 Pulser OFF
DSSSD bias & leakage currents - attachment 1
FEE64 temperatures OK - attachment 2
All system wide checks OK, WR timestamps OK - attachment 3
ADC data item stats - attachment 4
Rates dominated by two hot channels aida15 per FEE64 Stat spectra - attachment 5
per FEE64 1.8.L spectra - attachments 6-7 no obvious beam energy peak, continuum of energies from below beam energy to threshold
per FEE64 1.8.W spectra - attachments 8-9
22.55 Start data file APR24/R5 Merger, TapeServer etc - attachments 10-12
270k data items/s
23:29 Activated CARMESort script. See attachments 13-15.
No obvious beam or signal of any kind. Temperatures OK.
00:13 DAQ continues OK. System-wide check OK. Temps OK. Still no clear sign of beam.
01:03 Daq continues OK. System wide checks OK, Temps OK.
Only low energies observed in the energy spectrum. Looks a bit like the low energy noise observed in our previous runs with no/very few counts above what would be beam energy (~7.6 MeV)
Note the xy plots are not all orientated correctly (strips are correct in the sort code but root axis need to be flipped - I can;t remember how atm). The part of the plots with counts are those closest to the beam.
02:00 DAQ continues OK. System wide checks OK. Temps OK.
Spectra still looks the same. I have noticed the right hand side rate is higher than the left. EyEx cut spectrum also looks like much more counts outside of the cut.
03:40
DAQ continues. All checks and temps OK.
I can now see a small peak at 5 MeV in the bottom left dssd. This dssd also has the least number of counts in the low energy continuum.
I have logged back into grafana on x2go to get the number ions in the ring. Attachment 17
04:23 (05:23 EU)
DAQ stopped, merger stopped, tape server stopped. Bias OFF. FEEs turned OFF. Screen shots taken of the monitoring code plots - not yet uploaded.
Windows and servers remain up in case we want to do some more tests in the near future.
Attachment 18 shows beam intensity for total run time from Grafana |
550
|
Sun Apr 28 23:12:11 2024 |
TD | Monday 28 April | 00.09 DAQ continues data file R3_21
DSSSD bias & leakage current OK - attachment 1
FEE64 temps OK - attachment 2
ADC data item stats OK - attachment 3
per FEE64 Rate spectra - attachment 4
Merger, TapeServer etc - attachments 5-7
04.50 DAQ continues data file R3_22
DSSSD bias & leakage current OK - attachment 8
FEE64 temps OK - attachment 9
ADC data item stats OK - attachment 10
per FEE64 Rate spectra - attachment 11
Merger, TapeServer etc - attachments 12-14
09.41 DAQ continues data file R3_23
DSSSD bias & leakage current OK - attachment 15
FEE64 temps OK - attachment 16
ADC data item stats OK - attachment 17
per FEE64 Rate spectra - attachment 18
Merger, TapeServer etc - attachments 19-21
09.43 DAQ stopped
DSSSD bias OFF
FEE64 power OFF |
549
|
Sat Apr 27 23:16:02 2024 |
TD | Sunday 28 April |
00.12 DAQ continues data file R3_15
DSSSD bias & leakage current OK - attachment 1
FEE64 temps OK - attachment 2
ADC data item stats OK - attachment 3
per FEE64 Rate spectra - attachment 4
Merger, TapeServer etc - attachments 5-7
05.32 DAQ continues data file R3_16
DSSSD bias & leakage current OK - attachment 8
FEE64 temps OK - attachment 9
ADC data item stats OK - attachment 10
per FEE64 Rate spectra - attachment 11
Merger, TapeServer etc - attachments 12-14
11.27 DAQ continues data file R3_17
DSSSD bias & leakage current OK - attachment 15
FEE64 temps OK - attachment 16
ADC data item stats OK - attachment 17
per FEE64 Rate spectra - attachment 21
Merger, TapeServer etc - attachments 18-20
11.33 aida16 asic #2 2x Check ASIC control
aida16 asic #4 2x Check ASIC control
18.53 DAQ continues data file R3_19
DSSSD bias & leakage current OK - attachment 22
FEE64 temps OK - attachment 23
ADC data item stats OK - attachment 24
per FEE64 Rate spectra - attachment 25
Merger, TapeServer etc - attachments 26-28
per FEE64 1.8.H - attachments 29-30
per FEE64 1.8.L - attachments 31-32
per FEE64 1.8.W - 20us FSR - attachments 33-36
19.10 CRYRING ambient temperature per https://web-docs.gsi.de/~lestinsk/tempplot.php - attachment 37 |
548
|
Fri Apr 26 23:41:16 2024 |
TD | Saturday 27 April |
00.34 DAQ continues data file R3_9
DSSSD bias & leakage current OK - attachment 1
FEE64 temps OK - attachment 2
ADC data item stats OK - attachment 3
per FEE64 Rate spectra - attachment 4
Merger, TapeServer etc - attachments 5-7
06.41 DAQ continues data file R3_10
DSSSD bias & leakage current OK - attachment 8
FEE64 temps OK - attachment 9
ADC data item stats OK - attachment 10
per FEE64 Rate spectra - attachment 11
Merger, TapeServer etc - attachments 12-14
10.56 DAQ continues data file R3_11
DSSSD bias & leakage current OK - attachment 15
FEE64 temps OK - attachment 16
ADC data item stats OK - attachment 17
per FEE64 Rate spectra - attachment 18
Merger, TapeServer etc - attachments 19-21
14.33 DAQ continues data file R3_12
DSSSD bias & leakage current OK - attachment 22
FEE64 temps OK - attachment 23
ADC data item stats OK - attachment 24
per FEE64 Rate spectra - attachment 25
Merger, TapeServer etc - attachments 26-28
18.31 DAQ continues data file R3_13
DSSSD bias & leakage current OK - attachment 29
FEE64 temps OK - attachment 30
ADC data item stats OK - attachment 31
per FEE64 Rate spectra - attachment 32
per FEE64 1.8.L spectra - attachments 33-34
Merger, TapeServer etc - attachments 35-37 |
547
|
Fri Apr 26 07:05:01 2024 |
TD | Friday 26 April |
08.02 DAQ continues data file R1_14
DSSSD bias & leakage current OK - attachment 1
FEE64 temps OK - attachment 2
ADC data item stats OK - attachment 3
per FEE64 Rate spectra - attachment 4
Merger, TapeServer etc - attachments 5-7
10.40 Close file R1 and open file R2
Switch on pulser (relay line 50Hz)
per FEE64 Rate spectra - attachment 8
Check ASIC load x2 for aida09, aida10, aida12, aida15 aida16
per FEE64 Rate spectra - attachment 12
status quo ante
Pulser walkthrough
Pulser settings per https://elog.ph.ed.ac.uk/CARME/544
Amplituides 70,000-10,000 @ 10,000 step
per FEE64 1.8.L spectra - attachments 9-10
per FEE64 Rate spectra - attachment 11
11.05 Pulser OFF
Close file R2, open file R3
zero all histograms stats
background alpha run continues
20.33 DAQ continues data file R3_8
DSSSD bias & leakage current OK - attachment 13
FEE64 temps OK - attachment 14
ADC data item stats OK - attachment 15
per FEE64 Rate spectra - attachment 16
Merger, TapeServer etc - attachments 1-19
CAEN data log stopped 00:21 Friday 26 April
pi@nnrpi1:~/Programs/caenlogger $ caenlogger --config caenlogger_config_gsi.toml
2024-04-25 15:25:16.194 | INFO | caenlogger.__main__:main:117 - Config file provided.
Traceback (most recent call last):
File "/home/pi/.local/bin/caenlogger", line 10, in <module>
sys.exit(main())
File "/home/pi/.local/lib/python3.7/site-packages/caenlogger/__main__.py", line 135, in main
curses.wrapper(process, config_dic)
File "/usr/lib/python3.7/curses/__init__.py", line 94, in wrapper
return func(stdscr, *args, **kwds)
File "/home/pi/.local/lib/python3.7/site-packages/caenlogger/__main__.py", line 57, in process
Vmon = [ f for f in HV[5].strip().split(" ") if f ]
IndexError: list index out of range
Old log gzip'd and moved to directory ~/logs
[npg@carme-gsi ~]$ mv caen_current.dat.gz logs/0031260424-caen_current.dat.gz
20.45 Restarted logger program |
546
|
Thu Apr 25 02:31:25 2024 |
TD | Thursday 25 April |
03.27 DAQ continues - file APR24/R1_7
DSSSD bias & leakage current OK - attachment 1
ambient temperature 16.1 deg C
FEE64 temperatures OK - attachment 2
ADC data item stats OK - attachment 3
per n+n FEE64 1.8.L spectra - attachment 4
per FEE64 Stat spectra - attachment 5
Merger, TapeServer etc - attachments 6-8
10.19 DAQ continues - file APR24/R1_8
DSSSD bias & leakage current OK - attachment 9
ambient temperature 16.2 deg C
FEE64 temperatures OK - attachment 10
ADC data item stats OK - attachment 11
per FEE64 Stat spectra - attachment 12
Merger, TapeServer etc - attachments 13-15
NetVar merge variables - attachment 16
14.44 DAQ continues - file APR24/R1_10
DSSSD bias & leakage current OK - attachment 17
ambient temperature 16.5 deg C
FEE64 temperatures OK - attachment 18
ADC data item stats OK - attachment 19
per FEE64 Stat spectra - attachment 20
some HEC data has appeared
Merger, TapeServer etc - attachments 21-23
19.12 DAQ continues - file APR24/R1_11
DSSSD bias & leakage current OK - attachment 24
ambient temperature 16.5 deg C
FEE64 temperatures OK - attachment 25
ADC data item stats OK - attachment 26
per FEE64 Stat spectra - attachment 27
per FEE64 1.8.L spectra - attachments 28-29
Merger, TapeServer etc - attachments 30-32
23.14 DAQ continues - file APR24/R1_12
DSSSD bias & leakage current OK - attachment 33
ambient temperature 16.1 deg C
FEE64 temperatures OK - attachment 34
ADC data item stats OK - attachment 35
per FEE64 Stat spectra - attachment 36
Merger, TapeServer etc - attachments 37-39 |
|