Wed Apr 3 13:29:20 2019, CA, CB, TD, report - high DAQ stall    
|
aida10 runs very fast for a period, then stops.
Have to restart Merger and TapeServer to get it running again.
|
Wed Apr 3 09:28:07 2019, CA, CB, TD, Wednesday April 3rd 2018 11x
|
Arrived at 09:54 - sequenced all FEE64 on
FEE64 not mounted properly - something happened to network overnight, see attachment 1,2 for AIDA system log
|
Tue Apr 2 09:42:20 2019, NH, MBS Server setup
|
MBS is currently configured and accepting data:
x86l-94 : AIDA Foreign data receiver
x86l-4 : DESPEC Time sorter |
Tue Apr 2 07:39:44 2019, CB, TD, CA, Tuesday 2nd April 2019 36x
|
08:15 beam tuning in progress
08.30 System wide checks
|
Mon Apr 1 10:20:20 2019, CA, NH, TD, MBS Relay startup 
|
To start the MBS Data Relay, click on the top rightmost of the MIDAS icons (MBS relay, Data Relay => MBS) in
Desktop 3. (attachment 1)
|
Mon Apr 1 10:14:09 2019, CA, NH, TD, Friday 29th March 2019  
|
16:30 good event statistics ok, with 9,10,11,12 running faster (detector FEE64s) (attachment 1)
FEE temperatures ok (attachment 2)
|
Mon Apr 1 08:50:35 2019, CA, TD, Monday April 1st 2019 - BEAM START 18x
|
09.28 System wide checks - aida06 global clock failure (check clock status)
- aida02 , aida04, aida06 fail calibration (ADC calibration)
|
Tue Mar 26 14:59:30 2019, NH, 26.03.2019 
|
Fig1: FEE temperatures from 26.03.2019 all OK
AIDA has been on today and merger setting fixed (see previous ELOG entry https://elog.ph.ed.ac.uk/DESPEC/36)
Still diagnosing issues with MBS (figure 2) but local data acquisition should be functional. |
Tue Mar 26 14:58:09 2019, NH, VP, How to reset merger
|
If the merger doesn't show "xfer Links => Merger" at the top, it is probably the merger setting has been corrupted somehow. This is
how to reset it
If you go to the web page from which you started the Merge and TapeServer |
Mon Mar 25 14:44:33 2019, NH, Merger issues    
|
Plastic electronics have now been installed.
Water is not leaking still.
FEE64s powered on at 15:00 to test MBS connection (fig1: temperatures) |
Fri Mar 22 15:44:20 2019, NH, End of 22.03.2019
|
End of the day - Detector unbiased and FEE64s turned off for the weekend as they won't be monitored.
Water will remain on. |
Fri Mar 22 14:31:24 2019, NH, A few more setup notes I forgot   
|
Extra FEE information:
HV braid (0 V) goes into FEE10 (beam left) with LK1 jumper
HV core (-160 V) goes into FEE09 (top) |
Fri Mar 22 13:47:32 2019, NH, Resolution Checks  
|
Pulser widths of AIDA modules, resolution is fairly typical. AIDA09 still noisier than other DSSD channels.
Figure 1: Picture of pulser peaks
Figure 2: Raw waves (AIDA01 did not calibrate, so AIDA02 used instead as "non DSSD module") |
Fri Mar 22 13:32:55 2019, NH, AIDA Startup @ 22.03.2019 
|
FEEs have been on this morning, temperatures attached
Leakage current attached
the DSSD is attached to the following AIDA modules: |
Thu Mar 21 15:45:48 2019, NH, AS, SA, MP, Snout Mounting & DSSD Bias
|
The AIDA snout (with single DSSD and plastic) has been mounted in S4 cave again. DSSD was connected to the outer 4 FEEs again.
-160 V Bias applied and DSSD holds voltage with leakage current of around 1.3 uA (was dropping as only biased briefly)
Bias off and FEEs offline again now as day nearly done. MBS testing will be performed shortly, as well as resolution checks. |
Thu Mar 21 14:10:10 2019, NH, FEE Temperatures
|
All 12 FEEs powered up, and temperatures are OK.
Passed ASIC checks and system wide checks - now checking cabling and to mount snout. |
Thu Mar 21 13:59:08 2019, NH, AIDA Water
|
The AIDA water system has been repaired and not leaking.
The interlock did not light immediately, but power cable reconnected to box and now it works.
|
Wed Mar 20 15:35:10 2019, NH, AIDA Setup @ GSI
|
Currently
- 1 DSSD and Plastic is in the AIDA snout, which is not mounted
- The FEEs are offline due to a water supply issue, this will be repaired early 21/03/2019 |
Sun Feb 3 16:01:49 2019, TD, Updated analyses GSIJan19/R1_0 - R10_0 7x
|
Summary statistics for WR test data files R1_0, R2_0, R3_0, R4_0, R7_0 and R10_0 (attachments 1-6)
|
Fri Jan 25 12:33:03 2019, NH, aida-gsi Access
|
If you have a GSI account it should be possible to connect to aida-gsi remotely via the following
SSH into lx-pool.gsi.de with GSI Linux username/password (ssh username@lx-pool.gsi.de)
Then SSH into aida-gsi via ssh npg@aida-3 |