AIDA GELINA BRIKEN nToF CRIB ISOLDE CIRCE nTOFCapture DESPEC DTAS EDI_PSA 179Ta CARME StellarModelling DCF K40
  nTOFCapture, Page 2 of 4  ELOG logo
IDup Date Author Subject Text Attachments
  21   Mon Oct 5 14:54:55 2020 Nikolay SosninOverall Progress: Monday Meeting 05.10.2020   Selenium_Data.pptx 
  22   Mon Oct 5 15:01:04 2020 RGMonday meeting slides: 05 OctSummary of work done so far.  2020_10_05_SummarySoFar.pdf 
  23   Mon Jan 25 16:11:54 2021 Nikolay Sosnin25.01.2021: Cross-section Calculation Update   Unresolved_Normalization_1.pptx 
  25   Sat Mar 19 17:29:43 2022 Nikolay SosninAl26 Experimental Inventory at n_TOFThree aluminium crates contain 26Al(n,
alpha) kit from EAR2, and was in the barracks
(building 6547) near detector lab by EAR1
 Al26_Inventory.pdf 
  26   Fri Jul 29 17:21:47 2022 RaganEnriched Si-30Attached are the pictures of enriched Si-30
metal pieces.
 IMG_2692.jpgIMG_2693.jpg 
  27   Tue Apr 11 14:07:43 2023 ClaudiaPhotos of the Zn68 measurement setupPhotos of the  68Zn(n,gamma) measuremement
setup at n_TOF EAR-1.
 IMG_20180409_204846530_LL.jpgIMG_20180409_204854032_LL.jpgIMG_20180410_180042179_LL.jpgIMG_20180411_140834699_LL.jpgZn68measurement.jpg 
  28   Thu Jun 15 09:57:01 2023 AnnieSi Set UpSi Set up images and documentation.

Detector 1 - C6D6D: Distance= 9
cm, Angle= 135 deg relative to BL (check
 12x 
  29   Thu Jun 22 10:37:39 2023 AnnieGold 22mm Sample ImagesNew 22mm sample compared to old 20mm sample
used at the beginning of the campaign
+ picture of dummy target in the setup.
 IMG_2187.JPGIMG_2186.JPGIMG_2185.JPG 
  30   Thu Jun 29 09:21:13 2023 AnnieInfo on SamplesBoth Au samples (20mm and 22mm) are single
mylar.

Both Si30 (22mm) and natSi (20mm) are
 IMG_2242.JPGIMG_2248.JPGIMG_2247.JPGIMG_2246.JPG 
  31   Thu Jul 13 12:27:44 2023 Michael Donnachie, CLWCalibration ParametersCalibration parameters for each detector:




detector
y-intercept
 24x 
  32   Thu Jul 13 14:19:37 2023 Claudiadead time 30Si runDefault TTOFSort dead time setting of 30
ns is ok.
 consecutiveau22.pdf 
  33   Sat Jul 15 07:33:32 2023 Nikolay Sosnin30Si EAR28 sTED + 2 C6D6

C6D6: distance = 14 cm, angle =
135 degrees
 6x 
  34   Mon Jul 17 10:06:35 2023 Nikolay SosninState of the Union: Campaign Update 17.07.2023EAR1: Si-nat sample fell off the holder
during maintenance (before run 116544), appears
intact and undamaged. Placed it back in-beam
 Sinat_PostFall.JPGEAR2_30Si_Alignment.JPGEAR2_30Si.JPG 
  35   Mon Jul 17 11:30:54 2023 ClaudiaProperties Silicon powder samples30Si
Mass: 0.9925(1) g;    Diameter:
22.22(1) mm;    Thickness: 1.77(4)
  
  36   Mon Jul 17 12:30:28 2023 Nikolay SosninSi-nat Goodfellow Sample PropertiesGoodfellow sample has been deposited on
a single Mylar foil and glue is drying.

mass = 2.932 g
 Sinat_Sample_Properties.JPG 
  37   Mon Jul 17 14:49:16 2023 Nikolay SosninMounted Si-nat SampleGoodfellow Si-nat mounted at EAR1. First
run: 116551
 Sinat_Back.JPGSinat_Front.JPGSinat_Sample.JPG 
  38   Fri Jul 21 10:45:22 2023 Michael DonnachieConsistency Checks BCT PKUP comparrisonsThe ratios for BCT/PKUP for Si, Au20, Au22,
Dummy, Empty and Sinat goodfellow have been
plotted. Also included is the normalised
 12x 
  39   Mon Jul 24 10:32:39 2023 Michael DonnachieConsistency Checks BCT PKUP SILIThe EAR1 ratios of BCT/PKUP, BCT/SILI and
PKUP/SILI plotted for each run for samples
Si, Sinat goodfellow, Au20, Au22, Empty and
 6x 
  40   Fri Jul 28 12:07:33 2023 Michael DonnachieEAR2 C6D6 timeshift issuesThere seems to be issues with the EAR2
C6D6 T histograms. For Au the earlier run
seems to be shifted for detector 2 compared
 Au20_C6D6_both_det_timeshift.pdfAu22_C6D6_both_det_timeshift.pdfSi30_C6D6_bothdet_3runs.pdf 
  41   Fri Jul 28 12:19:10 2023 Michael DonnachieEAR2 consistency checks, PKUP BCT SILI and normalised counts The EAR2 ratios of BCT/PKUP, BCT/SILI
and PKUP/SILI plotted for each run for samples
Si, Sinat, Au20, Au22 and Dummy. 
 10x 
ELOG V3.1.4-unknown